Field Controls TM-2000 - Manual

Field Controls TM-2000

Field Controls TM-2000 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 2 – Figure 2
  • Page 4 – Figure 9
  • Page 5 – Table 1
  • Page 6 – MAINTENANCE; and transformer disconnected.; TROUBLESHOOTING GUIDE
  • Page 7 – Table 3; Replacement Nozzle Kit*
  • Page 8 – HUMIDIFICATEUR RÉSIDENTIEL; Localiser le PLÉNUM D’ALIMENTATION de votre fournaise à air; Schéma 2
  • Page 10 – Schéma 9
  • Page 11 – Tableau 1; Tableau 2
  • Page 12 – ENTRETIEN PÉRIODIQUE; Fermer complètement la vanne à étrier.; GUIDE DE DÉPANNAGE
  • Page 13 – Tableau 3; Kit De Remplacement De L’embout*
  • Page 14 – HUMIDIFICADOR PARA TODA LA CASA; El TM-2000 no se debe usar en calderas; Figura 2
  • Page 17 – Conecte el transformador en el receptáculo.; Tabla 1; ESTÁNDAR; Tabla 2
  • Page 18 – Cierre totalmente la válvula de horquilla.; GUÍA PARA SOLUCIÓN DE PROBLEMAS; F, ajuste el ventilador de la caldera
  • Page 19 – Tabla 3; Juego de la boquilla de reemplazo*
  • Page 20 – WARRANTY INFORMATION
Loading the manual

WHOLE HOUSE HUMIDIFIER

Model: TM-2000

The TM-2000 Humidifier is activated by heated air being produced by your furnace. Its thermal sensing circuitry
monitors the temperature of the heated air. When the air is warm enough, the Housing Assembly’s electric
water valve is actuated, opening to allow cold water from your plumbing system to be atomized into a fine mist.
This mist is discharged into the heated air by the Remote Nozzle Bracket Assembly, where it immediately
evaporates and is distributed throughout your household. The TM-2000 is supplied water from your plumbing
system by the Saddle Valve Assembly, and is safely powered with reduced voltage by the 120/24 VAC
Transformer, which plugs into an ordinary 120-volt wall outlet.

The TM-2000 is ideal for use with conventional gas or oil forced-air central heating systems.

WARNING:

The TM-2000 is not be used on 90+ condensing furnaces, electric heat pumps or homes

with well-water systems.

I

TEMS INCLUDED IN KIT

:

(DO NOT INSTALL HUMIDIFIER IF ALL OF THESE ITEMS ARE NOT PRESENT!)

Housing Assembly

Remote Nozzle Bracket

Plastic Tubing (3 - 10' Sections)

Saddle Valve Assembly

Housing Mounting Template

Includes 5 Each: Compression Nuts, sleeves, and inserts

Remote Mounting Template

Mounting Components

Power Supply Wire

Includes: (4) #8-15 X 3/4" Hex Head Housing

Quick Connect Terminals (2)

(3) #8-15 X 1/2" Hex Head Remote

120/24 VAC Transformer

Bracket Mounting Screws

Instruction Manual

(3) #8 Speed Nuts For Remote Bracket Mounting.

O

PTIONAL ACCESSORIES

:

Air Booster Activator Kit
Humidistat

NOTE:

The TM-2000 is designed to operate on normal city water supply

pressure. If any other type of water supply is to be used it must be capable of
providing a minimum pressure of 50 psi.

DO NOT DESTROY

READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE OF REPLACEMENT PARTS, OPTIONAL

COMPONENTS, AND TROUBLESHOOTING INFORMATION.



120VAC/24VAC

Transformer

Plastic Tubing (3-10’ Sections)

10’ Power Supply Wire

Saddle Valve Assembly

English ...... Page 1
Français ..... Page 8
Espanõl ..... Page 14

Housing Assembly

Remote
Nozzle Bracket

PRODUCT QUESTIONS…

CALL FIELD FIRST

Phone: (252)522-3031

E-mail:

[email protected]

for answers on product maintenance,

operation or replacement part questions.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Figure 2

Page 2 INSTALLATION AND ADJUSTMENT PLEASE READ COMPLETELY BEFORE BEGINNING INSTALLATION! CAUTION: The TM-2000 is not to be used on electric furnaces, heat pumps, or in locations where the air temperature could drop below 40°F. The mounting position of the mounting position of the TM-2000 is very imp...

Page 4 - Figure 9

Page 4 Clip the three speed nuts over the mounting holes as shown in Figure 9. 9. Attach the Remote Nozzle Bracket to the plenum, using the three #8-15 x 1/2” long hex head sheet metal screws. 10. Locate a cold water line, upstream of any water softener, within 10 feet of the Remote Nozzle Bracket A...

Page 5 - Table 1

Page 5 H UMIDIFIER A DJUSTMENT The TM-2000 must now be adjusted so that it activates after heated air circulation begins, and de-activates before the heated air circulation ends. 1. Turn the adjustment knob on the Housing Assembly to the lowest sensitivity setting (fully clockwise). Set the Housing ...

Other Field Controls Models

All Field Controls Other