Field Controls FC95HRV. - Manual

Field Controls FC95HRV.

Field Controls FC95HRV. – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – Table of Contents; PLEASE READ THIS MANUAL; CAUTION; WARNING; extremely; to confirm the polarity of the power line; ATTENTION; NOTE
  • Page 3 – Ventilation and Control Options*; Operation and Installation Manual; DEHUMIDISTAT DISABLE; How the Dehumidistat Works (Colder Climates); DEFROST MODE; Glossary and Additional Information
  • Page 4 – Set to the desired humidity; Setting the Control
  • Page 6 – Select Button
  • Page 8 – # DHVC Ventilation Control; WARRANTY; Units carry a LIFETIME warranty on the; All units conform to CSA and UL standards.; Performance
  • Page 9 – Port Configuration and Airflow; FC95HRV Air Flow; Round port bent to oval
  • Page 10 – Units carry a LIFETIME warranty on the heat
  • Page 11 – INSTALLER SELECTABLE HIGH SPEED SETTINGS; Adjustable DIP switches are located on the circuit board. Hi3 is
  • Page 12 – All units conform to CSA and UL; WEIGHT; year replacement parts warranty.
  • Page 13 – Optional; Fully Dedicated Installations; T h e F u l l y D e d i c a t e d; Installation Methods
  • Page 14 – Installation Notes; Simplified Installation Diagrams; Key Points; Sizing the Ductwork; DIRECT CONNECTION of the SUPPLY AIR STREAM and
  • Page 15 – • Unit is normally balanced on HIGH speed with the furnace blower ON.; Spring-Loaded Backdraft Damper; Install the Backdraft Damper with the leaf hinge vertical.; Partially Dedicated Installation Diagrams
  • Page 16 – Fully Dedicated Installation Diagrams
  • Page 17 – service or maintenance can cause property; Suspend the Unit with the Adjustable Hanging Straps
  • Page 18 – DRAIN HOSE PLUMBING; HARD PIPE PLUMBING; Note: Secondary drain pan may be required to protect from
  • Page 19 – must be; Weatherhoods
  • Page 20 – Standard Series Controls; Figure E; Figure B; Side View; Front View of Back Plate; Figure D; Drill holes in wall; Correct Installation; Figure F
  • Page 21 – Yellow on timer to YELLOW #4; initiates high speed; Yellow; NOTE ABOUT TIMERS
  • Page 22 – Illustration of HHSC Control with cover off
  • Page 23 – Installation of the Healthy Home SystemTM Control (HHSC); HHSC CONTROL; Setting up the HHSC Control
  • Page 26 – Interlocking the HRV/ERV to an Air Handler/Furnace Blower; Setting “Standby” when using a Main Control; * Speed 0 is not available on all controls; Adding Dry Contact Controls; Low Speed; The Terminal Block
  • Page 27 – DUCT; AIR; Pitot tube and gauge; Balancing the Air Flows; with a Pitot Tube Attachment
  • Page 28 – Balancing the Air Flows with a Pitot Tube; Stale Air From Building; Magnehelic Gauge must be level.; Determining the cfm; After balancing the air flows, calculate the cfm flow rate.; Example; cfm = feet per minute x cross section area of duct
  • Page 29 – Air Flow Balancing using the Door Ports; Magnehelic Gauge hoses connected to; Airflow Reference Charts
  • Page 30 – Balancing Dampers; fresh air to
  • Page 31 – Troubleshooting your HRV/ERV System
  • Page 32 – LEAVE FOR HOMEOWNER; Residential Wiring Diagram
Loading the manual

69-Field

0412

Heat Recovery Ventilators

Operation and Installation Manual

This product earned the ENERGY STAR by

meeting strict energy efficiency guidelines set by

Natural Resources Canada and the US EPA. It

meets ENERGY STAR requirements only when

used in Canada.

*

FC95HRV*

FC155HRV

FC200HRV*

FC150ERV

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Table of Contents; PLEASE READ THIS MANUAL; CAUTION; WARNING; extremely; to confirm the polarity of the power line; ATTENTION; NOTE

Getting to Know your Heat and Energy Recovery Ventilator Ventilation and Control Options How the Dehumidistat Works (Colder Climates) Glossary and Additional Information Warranty........................................................................................3 Healthy Home System™ Control (HH...

Page 3 - Ventilation and Control Options*; Operation and Installation Manual; DEHUMIDISTAT DISABLE; How the Dehumidistat Works (Colder Climates); DEFROST MODE; Glossary and Additional Information

3 Thank you for purchasing a Field Control Heat/Energy Recovery Ventilator (HRV/ERV). The HRV/ERV provides fresh air to your home while recovering energy from the air it exhausts. There are numerous benefits to a properly installed, operated, and maintained HRV/ERV: • Exhausts the stale, contaminate...

Page 4 - Set to the desired humidity; Setting the Control

Your HRV/ERV system produces a dehumidifying effect when outdoor humidity levels are lower than indoor humidity levels. These conditions occur normally when outdoor termperatures are below 60°F. An additional dehumidification effect is achievable with the Optional Dehumidistat (Part DH1).The Optiona...

Other Field Controls Models

All Field Controls Other