  • Page 2 – ELECTRICAL RATINGS; determining equivalent length of vent pipe.
  • Page 3 – MAXIMUM EQUIVALENT HORIZONTAL PIPE LENGTH (FEET); VENTER MODEL NO. AND VENT PIPE DIAMETER; EQUIVALENT LENGTH (FEET) OF VENT PIPE FOR VENT PIPE FITTINGS; Step 1
  • Page 4 – INSTALLATION SAFETY INSTRUCTIONS; plumbing inside walls.; Diagram A
  • Page 5 – INSTALLATION OF POWER VENTER; Disconnect electrical power before wiring power venter!
  • Page 7 – ADJUSTMENTS; check for negative pressure problems in the building.; *Typical post purge time should be between 3 to 5 min.; Figure 4; Figure 8; Figure 7
  • Page 8 – GENERAL INSTALLATION INSPECTION; the heating appliance will operate continuously.; MAINTENANCE; flow. Remove all foreign materials before operating.
  • Page 9 – PV SERIES POWER VENTER: VERTICAL VENTING OPTION; Maximum input temperature at power venter: 575°F; Diagram D
  • Page 10 – DESCRIPTION; VENTING SYSTEM OPERATIONAL INFORMATION
  • Page 11 – NOTES
Loading the manual

2630 Airport Road · Kinston, NC 28504

Phone: 252-522-3031· Fax: 252-522-0214

www .fieldcontrols.com

POWER VENTER SYSTEM

Model: PVO-300, PVO-600

Included is one ETL and cETL listed Power Venter to be used primarily with a
single 120VAC controlled oil fired furnace, boiler, or water heater. The PVO
may be used to common vent multiple appliances with the addition of a Control
Kit. Please consult Field Control’s Technical Support for other options.

TYPICAL VENTING SYSTEM COMPONENTS

One PVO Series Power Venter with pre-wired controls; adjustable post
purge relay timer, adjustable draft proving switch, direct access terminal
blocks, and piping tee for multiple appliance systems.

• Side Wall Vent Hood (Not included)

• Spill Switches (Not included)

• CK-Series Control Kit for multiple appliance venting (Not Included)

C

ONTENTS

P

AGE

Unit Specifications

2

System Operation

2

Power Venter Sizing

3

Installation Safety Instructions

4

Installation of Power Venter

5

General Wiring Instructions

5-6

Airflow Adjustments

7

Pressure Switch Adjustments

7

Post Purge Timer Adjustments

7

Multiple Appliance Systems

7

General Installation Inspection

8

Maintenance 8
Replacement Parts List

9

Venting System Operational Information

10

Installation Information

10

This device MUST be installed by a qualified agency in accordance with the manufacturers installation
instructions.

The definition of a qualified agency is:

any individual, firm, corporation or company which either in person or through a representative is

engaged in, and is responsible for, the installation and operation of gas appliances, who is experienced in such work, familiar with all
the precautions required, and has complied with the requirements of the authority having jurisdiction.

DO NOT DESTROY

THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - ELECTRICAL RATINGS; determining equivalent length of vent pipe.

Page 2 UNIT SPECIFICATIONS (See Table 1 and Figure 1) Table 1 UNIT DIMENSIONS (INCHES) MODEL “H” “W” “D” I/O* PVO-300 7.50 9.25 7.00 4/4 PVO-600 8.75 9.75 8.50 4/4 * Inlet and outlet diameter. ELECTRICAL RATINGS MODEL VAC Hz RPM WATT AMP TP** PVO-300 120 60 3000 145 2.1 YES PVO-600 120 60 3000 167 1...

Page 3 - MAXIMUM EQUIVALENT HORIZONTAL PIPE LENGTH (FEET); VENTER MODEL NO. AND VENT PIPE DIAMETER; EQUIVALENT LENGTH (FEET) OF VENT PIPE FOR VENT PIPE FITTINGS; Step 1

Page 3 POWER VENTER SIZING In order to choose the correct size power venter for a particular installation, the total input firing rate and total equivalent length of vent pipe to be used must be known. Refer to Table 2 to determine the maximum allowable equivalent feet of pipe for each model used wi...

Page 4 - INSTALLATION SAFETY INSTRUCTIONS; plumbing inside walls.; Diagram A

Page 4 INSTALLATION SAFETY INSTRUCTIONS CAUTION: This device must be installed by a qualified installer in accordance with the manufacturer's installation instructions. Appliances should have a minimum of 75% combustion efficiency or have a maximum measured flue gas temperature of 550°F at the inlet...