Field Controls GSK-160A - Manual
Field Controls GSK-160A – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
2630 Airport Road · Kinston, NC 28504
Phone: 252-522-3031· Fax: 252-522-0214
www .fieldcontrols.com
GAS SPILLAGE SENSING KIT
Model: GSK-160A
(with automatic reset)
Installation of a spillage SAFETY Switch is recommended for
LP and Natural gas fired systems with gas barometric draft
controls.
This device is intended for installation on a
double-acting barometric draft control (such as the Field
Controls model MG-1) that is installed in the venting
system of an 80+ efficiency rated, fan-assisted gas-fired
appliance.
It is designed to detect flue gas spillage caused by a
blocked flue system and/or inadequate draft. This device MUST
be installed by a qualified installer in accordance with the
manufacturer's installation instructions. Wiring MUST be in
accordance with the National Electrical Code and applicable
local codes.
Before and after adding this safety control on existing
appliances, an installation inspection in accordance with the
National Fuel Gas Code 54, Z223.1 Appendix H should be
performed and a combustion analysis is recommended to
determine the operating condition of the appliance.
CAUTION:
Disconnect Electrical Power When Wiring Spillage
Switch
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.