TW30 Wall Control

SPECIFICATION and INSTRUCTION SHEET

FAN MODEL USED:

See Catalog or visit our website

www.fanimation.com

for more

information

How to Wire and Operate Your TW30 Wall Control

DESCRIPTION:

One DC Motor Ceiling Fan and Light, 6 Speed, Reversing Remote Control

3.

To make fan operational, remove the top panel then install

23A/12V battery (included) in wall control, with fan power off

, arrange code switches to desired code setting.

Then follow the remote code setting process. (If not used for

long periods of time, remove battery to prevent damage to

transmitter). Store the remote away from excessive heat or

humidly (Figure 3).

NOTE: If fan or supply wires are different colors than indicated,

have this unit installed by a qualified electrician.

WARNING

To avoid possible electrical shock, be sure electricity is

turned off at the main fuse box before wiring.

NOTE: If you are not sure if the outlet box is grounded,

contact a licensed electrician for advise, as it must be

grounded for safe operation.

BARE

WARNING

Check to see that all connections are tight, including ground,

and that no bare wire is visible at the wire connectors,

except for the ground wire. Do not operate fan until the

blades is in place. Noise and fan damage could result.

Figure 3

ON

ECE

ON

1
2
3
4
D

AC120V 60HZ

INPUT

WHITE (AC IN N)

AC SUPPLY

BLACK (AC IN L)

BLACK

BLACK

WHITE

NE

E

R

G

L

O

RT

N

O

C

LL

A

W

BLACK (TO MOTOR L)

K

C

AL

B

K

C

AL

B

)L

NI

C

A(

K

C

AL

B

E

RI

W

D

N

U

O

R

G

Figure 1

Figure 2

1. Installing Wall Control

(Figure 1):

• With electrical power still disconnected, remove the

existing wall plate and switch.

• Make wiring connections with wire nuts as shown in

Figure 1.

– One black wire from wall control unit to black

(TO MOTOR L).

– One black wire from wall control unit to black wire

leading to ceiling outlet box.

– One green wire from wall control unit to ground wire

leading to ceiling outlet box.

• Attach wall control unit to outlet box using the two

#6-32-19mm screws provided. (Figure 2)

• Restore electrical power.

• Attach wall plate to the switch control and using the two

#6-32-9mm screws provided.

NOTE:

If you want to change the blades: turn

the off→ change the blades →turn the power

on →replay the power setting process.

4.

Remote Control Setting and Speed (RPM) Setting

Process :

The fan is now ready for normal use.

1. After installing the unit and restoring power to your

fan, press and hold the “SET” button 1~5 seconds. You

must press the “SET” button within 60 seconds of

restoring power to the fan.

2.The fan will start to run and begin the control setting

process. The fan will run in both directions for a total of

approximately 5 minutes.

3. When the fan stops after approximately 5 minutes the

control and speed setting process is complete.