How to Wire and Operate Your Remote Control

CR500 Remote Control

DESCRIPTION:

3-speed ceiling fan control with light dimmer switch and canopy receiver.

ELECTRICAL SPECS:

120V, 60Hz, Fan 1.0 amps

FAN MODELS USED:

most Fanimation AC fans - see catalog or visit our website, fanimation.com for
more information

SPECIFICATION and INSTRUCTION SHEET

NOTE:

If fan or supply wires are different colors than

indicated, have this unit installed by a qualified electrician.

1.

If fan and/or light kit are controlled by a pull chain, fan
must be set to high and light kit must be switched on.

2.

Install Receiver in the Hanger Bracket:

• Connect wires using connectors as shown in Figure 2.

• Position all connected wires and receiver antenna to
allow installation of ceiling canopy. (Figure 3)
• Using canopy screws threaded into the hanger bracket
reinstall ceiling canopy.
• Restore electrical power

3.

Dip Switch Set Up

(Figure 1)

WARNING

To avoid possible electrical shock, be sure electricity is

Figure 3

Figure 2

NOTE:

The remote unit has 32 different code

combinations. To prevent possible interference from or
to other remote units, simply change the combination
code in the remote and receiver.

NOTE: Factory setting is all up. Do not use this position.

• To set the code on receiver unit, slide dip switches to
the same positions as set on the remote.

• To set the remote code with a small screwdriver or
ball point pen (neither included), slide dip switches
firmly up or down to same as receiver unit.

AC120V 60HZ

INPUT

WHITE (AC IN N)

BLACK (AC IN L)

BLUE

BLACK

WHITE

BLUE(FOR LIGHT)

BLACK(TO MOTOR L)

WHITE(TO MOTOR N)

BLACK

(ANTENNA)

WHITE

(AC IN N )

BLACK
(AC IN L)

BLACK

(TO MOTOR L)

WHITE

(TO MOTOR N)

BLUE

(FOR LIGHT)

Figure 1

Dip Switch

Dip Switch

ON DIP

1 2 3 4 5

WARNING

Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not operate
fan unless blades are in place. Noise and fan damage
could result.

To avoid possible fire or shock, make sure that the

electrical wires are completely inside the outlet box and

not pinched between the wall plate and the wall.