A Remote Control Manual for the CR500 system covers essential setup, installation, and operation of its wireless components. The guide emphasizes electrical safety, proper wiring–including dip switch configuration and receiver mounting–and explains how to configure controls for ceiling fans and light units. Key features include adjustable fan speeds, light toggles, and programmable timers, supported by visual diagrams for troubleshooting connections and usage.
Table of Contents:
- Page 1 – Remote Control Wiring and Receiver Installation
- Page 2 – Remote Control Functionality
- Page 3 – Ceiling Fan Wiring Instructions
- Page 4 – Ceiling Fan Receiver Installation and Remote Features
How to Wire and Operate Your Remote Control
CR500 Remote Control
DESCRIPTION:
3-speed ceiling fan control with light dimmer switch and canopy receiver.
ELECTRICAL SPECS:
120V, 60Hz, Fan 1.0 amps
FAN MODELS USED:
most Fanimation AC fans - see catalog or visit our website, fanimation.com for
more information
SPECIFICATION and INSTRUCTION SHEET
NOTE:
If fan or supply wires are different colors than
indicated, have this unit installed by a qualified electrician.
1.
If fan and/or light kit are controlled by a pull chain, fan
must be set to high and light kit must be switched on.
2.
Install Receiver in the Hanger Bracket:
• Connect wires using connectors as shown in Figure 2.
• Position all connected wires and receiver antenna to
allow installation of ceiling canopy. (Figure 3)
• Using canopy screws threaded into the hanger bracket
reinstall ceiling canopy.
• Restore electrical power
3.
Dip Switch Set Up
(Figure 1)
WARNING
To avoid possible electrical shock, be sure electricity is
Figure 3
Figure 2
NOTE:
The remote unit has 32 different code
combinations. To prevent possible interference from or
to other remote units, simply change the combination
code in the remote and receiver.
NOTE: Factory setting is all up. Do not use this position.
• To set the code on receiver unit, slide dip switches to
the same positions as set on the remote.
• To set the remote code with a small screwdriver or
ball point pen (neither included), slide dip switches
firmly up or down to same as receiver unit.
AC120V 60HZ
INPUT
WHITE (AC IN N)
BLACK (AC IN L)
BLUE
BLACK
WHITE
BLUE(FOR LIGHT)
BLACK(TO MOTOR L)
WHITE(TO MOTOR N)
BLACK
(ANTENNA)
WHITE
(AC IN N )
BLACK
(AC IN L)
BLACK
(TO MOTOR L)
WHITE
(TO MOTOR N)
BLUE
(FOR LIGHT)
Figure 1
Dip Switch
Dip Switch
ON DIP
1 2 3 4 5
WARNING
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not operate
fan unless blades are in place. Noise and fan damage
could result.
To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box and
not pinched between the wall plate and the wall.
WARNING
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
About this manual
- Brand
- Fanimation
- Model
- CR500
- Document type
- User Manual
- Category
- Remote Control
- Language(s)
- English, Spanish
- Pages
- 4
- File size
- 1.2 MB
- Format
Summary
Instructions for wiring and operating the CR500 Remote Control, including electrical safety warnings, dip switch configuration for code setup, receiver installation in the hanger bracket, and secure wire connections.
Explanation of remote control functions for fan speed, light controls, and sleep timer settings for a fan and light unit, accompanied by a diagram of the remote buttons.
Instructions for wiring and using the CR500 remote control for a ceiling fan, covering safety warnings, dip switch configuration, and wiring diagrams for the fan receiver and motor.