Champion 4001 DD - User Manual
Champion 4001 DD Evaporative Cooler – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Installation; Motor Installation; Wiring Diagrams; Champion Air Balancing Method
- Page 3 – Maintenance; WARNING; Before doing any maintenance be sure power is; WINTER SHUT DOWN; Amperage Draw And Belt Tension
- Page 4 – Limited Warranty; Troubleshooting; Problem Possible
- Page 5 – Replacement Parts List / Lista De Piezas De Recambio
- Page 6 – General Specifi cations / Especifi caciones Generales; Parts Drawing / Dibujo De Piezas
- Page 7 – Motor Specifi cations / Especifi caciones Del Motor
- Page 9 – El Método De PCM; Reglas De Seguridad; Para reducir el riesgo de incendio o toques; Enfriamiento Por Evaporación; La superfi cie en que ha de colocarse el; Lea y Conserve Estas Instrucciones
- Page 10 – Sistema de Purga
- Page 11 – Preparar La Unidad Para El Invierno; No permita que funcione esta unidad si toma; Mantenimiento; ADVERTENCIA; Antes de hacer cualquier mantenimiento,; Puesta En Marcha En La Primavera; Esquemas Del Cableado
- Page 12 – Garantía Limitada; La Localización De Averías
Models
3000
DD
N31D
3000
SD
N30S
4001
DD
N43/48D
4001
SD
N40/45S
5000
DD
N56/66D
5000
SD
N55/65S
Circle the model of your cooler and
record the serial number below.
Read carefully all of this manual before
installing the unit.
Encierre con un circulo el modelo de su
enfriador y escribe el número de serie abajo.
Lea con cuidad todo este manual antes de
instalar la unidad.
Número De Serie
Safety Rules
1. Read instructions carefully.
2. Electrical hook up should be done by a qualifi ed electrician, so
that all electrical wiring will conform to your local standards.
3. Always turn
OFF POWER
and
UNPLUG
motor and pump inside
the cooler before installing or performing any maintenance.
4. Your cooler will run on either 120V or 240V A.C., single phase,
60 Hz (cycle) current.
5. Motor and pump have a grounded, molded plug and an automatic
thermal overload switch which will shut motor off when it over-
heats. The motor will restart automatically when it cools down.
6. Pump receptacle is for grounded evaporative cooler pump only.
Do not plug anything else into receptacle.
WARNING
:
To reduce the risk of fi re or electric shock, do not
use this fan with any “solid-state fan speed control device.”
Read And Save These Instructions
Vea el Español en el interior
110503-1
8-08
Evaporative Cooling
Evaporative cooling is nature’s way of cooling. When air is moved
over a wet surface, water is evaporated and heat is absorbed. When
stepping out of a swimming pool with the wind blowing, evaporative
cooling makes you feel cool, even though the air may be warm.
The human body itself is cooled primarily by the evaporation of
perspiration.
This unit works on the same principle. Air is drawn across wet
fi lter pads where the air is cooled by evaporation and then circulated
throughout the building. It is this combination of cooled air and the
movement of air over the skin which makes it feel cool.
www.championcooler.com
C H A M P I O N • E S S I C K
Evaporative Cooler Manual
Unlike refrigeration systems which recirculate the air, an evaporative
cooler continually brings in fresh air while exhausting old air. You
are completely replacing the air every 2 to 4 minutes by opening
windows or doors or a combination of both. The air is always fresh,
not stale, laden with smoke and odors as happens with refrigerated
air conditioning.
Operation
For the best cooling performance, if the pads are dry, pre-wet the pads
by running the pump for a few minutes before starting the blower.
These coolers may be used without water for ventilation purposes.
When outside air is cool (for example, at night) or when humidity is
high, the water pump can be turned off.
A cooler can also be installed with a thermostat and attic exhaust
dampers to provide completely automatic operation.
Open Windows To Exhaust Air
An often misunderstood concept of evaporative cooling is the amount
of air that should be exhausted. How much should you open your
windows? The fact is that most people do not open their windows
enough. The following two methods will help you determine the
amount to open your windows.
CFM Method
You should allow an opening of at least 2 square feet (288 square
inches) for each 1000 CFM rating of your unit.
Example:
At 3654
CFM, model 4001 DD with a 1/2 hp motor requires 7.3 square feet
(1052 square inches) of opening (3654/1000 * 2 = 7.3). Multiply
the number of windows by window width in inches and divide this
into the number of square inches required for your size unit. This
will give you the height to open windows. In this example, four 36
inch wide windows should be opened 7.3 inches each.
Serial #
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 110503-1 Installation NOTE: The pump comes installed. The belt, motor pulley, and motor cord and fl oat are included in the cabinet, the motor is shipped separately. CAUTION: Make sure that the mounting surface is strong enough to support the operating weight of the cooler when in use. (For operat...
3 110503-1 • Install fl oat and attach water line to fl oat. The fl oat may be installed in either the corner post or bracket (see Fig. 9). If you have model 3000DD/N31D then the fl oat should be mounted to the bracket. Refer to fi gure 10 for installation instruc-tions. Insert the fl oat (1) thru t...
4 110503-1 Limited Warranty This warranty is extended to the original purchaser of an evaporative cooler installed and used under normal conditions. It does not cover dam-ages incurred through accident, neglect, or abuse by the owner. We do not authorize any person or representative to assume for us...