Page 2 - CPSMC08xx-100 PointSystemTM Chassis; 4 hour Technical Support:; Compliance Information; FCC Regulations
2 CPSMC08xx-100 PointSystem™ Chassis 24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 Compliance Information CISPR22/EN55022 Class A + EN55024CE Mark FCC Regulations This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant...
Page 3 - Table of Contents
3 CPSMC08xx-100 PointSystem™ Chassis Table of Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.2 Unpacking the CPSMC08xx-100 Equipment . . . . ...
Page 4 - introduction; Introduction; Description; PointSystemTM
4 CPSMC08xx-100 PointSystem™ Chassis introduction 1 Introduction 1.1 Description The Transition Networks PointSystem™ CPSMC08xx-100 is a 19-inch, rack- mountable chassis for selected Transition Networks media converter slide-in-modules. The chassis allows the network administrator to connect various...
Page 5 - Unpacking the CPSMC08xx-100 Equipment; Item
5 CPSMC08xx-100 PointSystem™ Chassis introduction 1.2 Unpacking the CPSMC08xx-100 Equipment Use the following list to verify the shipment: Item Part Number 8-Slot chassis with AC power supply CPSMC0800-100 8-Slot chassis with DC power supply CPSMC0810-100 PointSystem™ chassis face plates (5) CPSFP-2...
Page 6 - Chassis; Chassis Face Plates; The combined power; Failure to; plus
6 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 2 Slide-in-Modules 2.1 Media Converter Slide-in-Modules Transition Networks media converter slide-in-modules, installed in slots at the frontof the chassis, allow the network administrator to connect various copper and fiber-optic network media ...
Page 7 - Installing the Media Converter Slide-in-Modules; Wear a grounding device and observe electrostatic discharge
7 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 2.1.3 Installing the Media Converter Slide-in-Modules CAUTION: Wear a grounding device and observe electrostatic discharge precautions when installing the media converter slide-in-module(s) into the chassis. Failure to observe this caution could...
Page 8 - Replacing the Media Converter Slide-in-Modules; Failure to observe; the panel fastener screw is to the left.
8 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 2.2.4 Replacing the Media Converter Slide-in-Modules CAUTION: Wear a grounding device and observe electrostatic discharge precautions when replacing media converter sl...
Page 9 - Management Modules; CPSMM-120 Single-Slot Master Management Module; two; CPSMM-210 Single-Slot Expansion Management Module
9 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 2.2 Management Modules Optional network management is provided by SNMP software embedded inTransition Networks PointSystem ™ management module(s) that can be installed...
Page 10 - Installing the Management Modules
10 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 2.2.2 Installing the Management Modules CAUTION: Wear a grounding device and observe electrostatic discharge precautions when installing the management module(s) in t...
Page 11 - Replacing the Management Modules
11 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 2.2.3 Replacing the Management Modules CAUTION: Wear a grounding device and observe electrostatic discharge precautions when replacing media converter slide-in-module(s). Failure to observe this caution could result in damage to, and subsequent...
Page 12 - Power up the chassis by connecting the power supply.; Primary Power Supply; the installed slide-in-modules and by the chassis’ fan operation.
12 CPSMC08xx-100 PointSystem ™ Chassis power supply 3 Powering the CPSMC08xx-100 The CPSMC08xx-100 chassis can be powered through an AC or DC power supply.An optional auxiliary power supply, with instant fail over protection, is alsoavailable. NOTE: The CPSMC08xx-100 chassis does not have an ON/OFF ...
Page 13 - DC Power Supply; “chassis ground”. Turn the terminal screw clockwise to secure.
13 CPSMC08xx-100 PointSystem ™ Chassis power supply 3.1.2 DC Power Supply • This product is intended to be used in a restricted access location. Proper earthing(grounding) is required to ensure safe operation. Grounding terminals are provided(section 4.1.3) for proper grounding of the device as per ...
Page 14 - Auxiliary Power Supply; Instant Fail Over Protection; AC Auxiliary Power Supply; inlet on the back of the chassis.
14 CPSMC08xx-100 PointSystem ™ Chassis power supply 3.2 Auxiliary Power Supply The CPSMC08xx-100 chassis can also be supplied with auxiliary power from anexternal power converter, which is connected to the chassis through the auxiliarypower inlet, located on the back panel. (Both and AC and a DC ext...
Page 15 - DC Auxiliary Power Supply
15 CPSMC08xx-100 PointSystem ™ Chassis power supply 3.2.2 DC Auxiliary Power Supply • This product is intended to be used in a restricted access location. Proper earthing(grounding) is required to ensure safe operation. Grounding terminals are provided(section 4.1.3) for proper grounding of the devi...
Page 16 - chassis; Installing the CPSMC08xx-100 Chassis; Rack-mounted equipment must be reliably grounded. Power supply; other than direct connection; against the front or back edge of the rack; recessed; from the front or back edge of the rack.
16 CPSMC08xx-100 PointSystem ™ Chassis chassis 4 CPSMC08xx-100 Chassis 4.1 Installing the CPSMC08xx-100 Chassis The CPSMC08xx-100 can be installed in a standard 19-inch rack or on a table, shelf,or other stable surface. CAUTION: Install the chassis so that the air flow around it is not restricted. 4...
Page 18 - Grounding Lugs; grounding connector; The electrical conducting path from the chassis must:; must be fastened to the; To properly ground the CPSMC08xx-100 chassis:
18 CPSMC08xx-100 PointSystem ™ Chassis chassis 4.1.3 Grounding Lugs The CPSMC08xx-100 comes equipped with grounding lugs, which are provided fora grounding conductor wire terminated with a two-hole, compression-type, grounding connector . The grounding wire -- which must be a copper conductor -- is ...
Page 19 - Cascade Option
19 CPSMC08xx-100 PointSystem ™ Chassis chassis 4.2 Cascade Option The management module cascade option allows the network administrator toconnect up to eight (8) CPSMC08xx-100 chassis into one manageable stack,providing a single management source for up to 55 installed media converterdevices. To cre...
Page 20 - To cascade two or more CPSMC08xx-100 chassis:
20 CPSMC08xx-100 PointSystem ™ Chassis chassis To cascade two or more CPSMC08xx-100 chassis: 1. Locate one (1) Transition Networks management module cascade cable (with RJ-45 connectors installed at both ends) (P/N 6026) for each set of two (2)chassis to be cascaded. NOTE: Transition Networks manage...
Page 21 - Connecting the Slide-in-Modules to the Network
21 CPSMC08xx-100 PointSystem ™ Chassis chassis 24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 4.3 Connecting the Slide-in-Modules to the Network Once the CPSMC08xx-100 chassis has been installed, the media converter slide-in-modules may be connected to the network. CAU...
Page 22 - Network Management; FocalPointTM; Hardware Connections
22 CPSMC08xx-100 PointSystem ™ Chassis network mgmt. 24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 5 Network Management The CPSMM100 firmware and the FocalPoint™ application are described in the FocalPoint™ 2.0 Management Application and CPSMM100 Firmware user’s guide...
Page 24 - troubleshooting; Troubleshooting; YES; FocalPointTM 2.0 Management Application and
24 CPSMC08xx-100 PointSystem ™ Chassis troubleshooting 6 Troubleshooting 1. Are ANY of the POWER LEDs on any of the slide-in-modules illuminated; AND/OR are the fans operating?YES • The chassis is receiving power. Proceed to the next step. NO • Ensure all power supply cables for proper connection. •...
Page 25 - Technical Specifications; Storage Temperature:
25 CPSMC08xx-100 PointSystem ™ Chassis 24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 Technical Specifications For use with Transition Networks Model CPSMC08xx-100 or equivalent. Dimensions 17 x 10.4 x 1.8 inches (432 x 264 x 46 mm) Shipping Weight 8 lbs. (3.6 kg) AC P...
Page 26 - Cable Specifications; Null Modem Cable; Function
26 CPSMC08xx-100 PointSystem ™ Chassis 24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 Cable Specifications Null Modem Cable The Null Modem Cable is used for connecting a terminal or terminal emulator tothe management module’s DB-9 connector to access the command-line i...
Page 27 - COAX Cable
27 CPSMC08xx-100 PointSystem ™ Chassis COAX Cable Coaxial cable media is used for circuits such as DS3, E1 and 10Base-2 Ethernet. Theimpedance of the coaxial cable is determined by the interface type, for example:• 75 ohm for DS3. • 50 ohm for 10Base-2 Ethernet. Special attention should be given to ...
Page 28 - Contact Us; Technical Support; Technical support is available 24 hours a day.; Log onto; Log onto; Learning Center; Address
28 CPSMC08xx-100 PointSystem ™ Chassis Contact Us Technical Support Technical support is available 24 hours a day. United States: 1-800-260-1312 International: 00-1-952-941-7600 Transition Now Chat live via the Web with a Transition Networks Technical Support Specialist. Log onto www.transition.com ...
Page 29 - Warranty; Limited Lifetime Warranty; Replace the product with an equivalent functional product, or; We cannot accept delivery of any equipment that is sent to us
29 CPSMC08xx-100 PointSystem ™ Chassis Warranty Limited Lifetime Warranty Effective for products shipped May 1, 1999 and after. Every Transition Networks'labeled product purchased after May 1, 1999 will be free from defects in materialand workmanship for its lifetime. This warranty covers the origin...