Page 2 - Compliance Information; FCC Regulations
2 CPSMC0800-100 PointSystem™ Chassis Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600 Compliance Information UL ListedC-UL Listed (Canada)CISPR22/EN55022 Class A + EN55024CE Mark FCC Regulations This equipment has been tested and found to comply with the limits f...
Page 3 - Table of Contents
3 CPSMC0800-100 PointSystem™ Chassis Table of Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.2 Unpacking the CPSMC0800-100 Equipment . . . . ...
Page 4 - introduction; Introduction; Description; PointSystemTM
4 CPSMC0800-100 PointSystem™ Chassis introduction 1 Introduction 1.1 Description The Transition Networks PointSystem™ CPSMC0800-100 is a 19-inch, rack-mount- able chassis for selected Transition Networks Media Converter Slide-In-Modules.The CPSMC0800-100 allows the network administrator to connect v...
Page 5 - Item
5 CPSMC0800-100 PointSystem™ Chassis introduction 2.1 Unpacking the CPSMC0800-100 Equipment Use the following list to verify the shipment: Item Part Number 8-Slot chassis with AC power supply CPSMC0800-100 8-Slot chassis with DC power supply CPSMC0810-100 Power Cord (varies by country) External AC P...
Page 6 - Chassis; Calculating the Power Consumption; plus
6 CPSMC0800-100 PointSystem ™ Chassis slide-in-modules 2 Slide-in-Modules 2.1 Media Converter Slide-in-Modules Transition Networks Media Converter Slide-in-Modules, installed in slots at the frontof the chassis, allow the network administrator to connect various copper and fiber-optic network media ...
Page 7 - Installing the Media Converter Slide-in-Modules; the back of the chassis.
7 CPSMC0800-100 PointSystem ™ Chassis slide-in-modules 2.1.2 Installing the Media Converter Slide-in-Modules CAUTION: Wear a grounding device and observe electrostatic discharge precau-tions when installing the Media Converter Slide-in-Module(s) into the chassis.Failure to observe this caution could...
Page 8 - Replacing the Media Converter Slide-in-Modules; lation slot so that the panel fastener screw is to the left.
8 CPSMC0800-100 PointSystem ™ Chassis slide-in-modules Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600 2.2.3 Replacing the Media Converter Slide-in-Modules CAUTION: Wear a grounding device and observe electrostatic discharge precau-tions when replacing Media Con...
Page 9 - Management Modules; CPSMM-120 Single-Slot Master Managment Module; PointSystem; two; CPSMM-210 Single-Slot Expansion Management Module
9 CPSMC0800-100 PointSystem ™ Chassis slide-in-modules Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600 2.2 Management Modules Optional network management is provided by SNMP software embedded inTransition Networks PointSystem ™ Management Module(s) that can be i...
Page 10 - Installing the Managment Modules
10 CPSMC0800-100 PointSystem ™ Chassis slide-in-modules Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600 2.2.2 Installing the Managment Modules CAUTION: Wear a grounding device and observe electrostatic discharge precau-tions when installing the Management Module...
Page 11 - Replacing the Mangement Modules; The Managment Modules are; NOT; To replace a Managment Module:
11 CPSMC0800-100 PointSystem ™ Chassis slide-in-modules 2.2.3 Replacing the Mangement Modules CAUTION: Wear a grounding device and observe electrostatic discharge precau-tions when replacing Media Converter Slide-in-Module(s). Failure to observe thiscaution could result in damage to, and subsequent ...
Page 12 - Power up the chassis by connecting the power supply.; Primary Power Supply
12 CPSMC0800-100 PointSystem ™ Chassis power supply 3 Powering the CPSMC0800-100 The CPSMC0800-100 chassis can be powered through an AC or DC Power Supply.An optional auxilliary power supply, with Instant Fail Over protections, is also avail-able. NOTE: The CPSMC0800-100 8-Slot chassis does not have...
Page 13 - Auxilliary Power Supply; Inlet on the back of the 8-Slot chassis.
13 CPSMC0800-100 PointSystem ™ Chassis power supply 3.2 Auxilliary Power Supply The CPSMC0800-100 can also be supplied with auxilliary power through theAuxilliary Power Inlet, located on the back panel. The External Power Converter andadditional power cord are sold separately. To power the CPSMM0800...
Page 14 - chassis; Standard 19-inch Rack Installation; The maximum recommended ambient temperature (Tmra) for the 8-Slot
14 CPSMC0800-100 PointSystem ™ Chassis chassis 4 CPSMC0800-100 Chassis 4.1 Installing the CPSMC0800-100 Chassis The CPSMC0800-100 can be installed in a standard 19-inch rack or on a table,shelf, or other stable surface. 4.1.1 Standard 19-inch Rack Installation NOTE: The maximum recommended ambient t...
Page 15 - and clip nuts are NOT provided.; Table-Top Installation
15 CPSMC0800-100 PointSystem ™ Chassis chassis To install the CPSMC0800-100 8-Slot chassis into a standard 19-inch rack: 1. Determine the preferred alignment of the 8-Slot chassis in the rack. NOTE: Installation bracket mounting screws are provided. Rackmount screws and clip nuts are NOT provided. 2...
Page 16 - Cascade Option
16 CPSMC0800-100 PointSystem ™ Chassis chassis 4.2 Cascade Option The Management Module cascade option allows the network administrator to con-nect up to eight (8) CPSMC0800-100 8-Slot chassis into one manageable stack, pro-viding a single management source for up to 55 installed Media Converter dev...
Page 17 - cade cable into the Management Module’s RJ-45 port labeled “OUTPUT”.; Connecting the Slide-in-Modules to the Network
17 CPSMC0800-100 PointSystem ™ Chassis chassis To cascade two or more CPSMC0800-100 8-Slot chassis: 1. Locate one (1) Transition Networks CPSMC0800-100 Management Module cas- cade cable (with RJ-45 connectors installed at both ends) for each set of two (2)chassis to be cascaded. NOTE: Transition Net...
Page 18 - Operation
18 CPSMC0800-100 PointSystem ™ Chassis chassis Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600 4.4 Operation Daily operation of the CPSMC0800-100 8-Slot chassis requires no network admin-istrator activity except for the occasional monitoring of the status LED in...
Page 19 - SNMP Agent in the Management Module; SNMP; The SNMP agent includes the Transition Networks; Command Line; In addition, Transition Networks; software; can be installed in the net-; SNMP Hardware Connections
19 CPSMC0800-100 PointSystem ™ Chassis SNMP Tech Support: M-F 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600 5 SNMP Agent in the Management Module Both Management Modules (CPSMM-120 and (CPSMM-200) have an SNMP (Simple Network Managment Protocol) Agent installed in the modul...
Page 20 - RJ-45 EthernetTM Port; Using the Transition Networks; SNMP Software
20 CPSMC0800-100 PointSystem ™ Chassis SNMP Tech Support: M-F 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600 RJ-45 Ethernet™ Port The RJ-45 Ethernet™ Port allows the network administrator to manage theCPSMC1800-100 8-Slot chassis via a remote Network Management Station (NMS)...
Page 21 - troubleshooting; Fault Isolation and Correction; YES
21 CPSMC0800-100 PointSystem ™ Chassis troubleshooting 6 Fault Isolation and Correction 1. Are ANY of the POWER LEDs on any of the Slide-in-Modules illuminated; AND/OR are the fans operating?YES • The chassis is receiving power. Proceed to the next step. NO • Ensure all power supply cables for prope...
Page 22 - Technical Specifications; Storage Temperature:; With Optical Instruments.; DECLARATION OF CONFORMITY
22 CPSMC0800-100 PointSystem ™ Chassis Tech Support: M-F 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600 Technical Specifications For use with Transition Networks Model CPSMC0800-100 or equivalent. Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subc...
Page 23 - Cable Specifications; Null Modem Cable; Function
23 CPSMC0800-100 PointSystem ™ Chassis Tech Support: M-F 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600 Cable Specifications Null Modem Cable The Null Modem Cable is used for connecting a terminal or terminal emulator tothe Management Module’s DB-9 connecdtor to access the c...
Page 24 - Contact Us; Technical Support; Transition Now; Log onto; Learning Center; Address
24 CPSMC0800-100 PointSystem ™ Chassis Contact Us Technical Support Technical support is avialable 7:00 AM - 6:00 PM CST (GMT -6:00) United States: 1-800-260-1312 International: 00-1-952-941-7600 Transition Now Chat live wia the Web with a Transition Networks Technical Support Specialist. Log onto w...
Page 25 - Warranty; Limited Lifetime Warranty; Replace the product with an equivalent functional product, or; We cannot accept delivery of any equipment that is sent to us with-
25 CPSMC0800-100 PointSystem ™ Chassis Warranty Limited Lifetime Warranty Effective for Products Shipped May 1, 1999 and After. Every Transition Networks'labeled product purchased after May 1, 1999 will be free from defects in materialand workmanship for its lifetime. This warranty covers the origin...