Teledyne Model 300EU - Manuals
Teledyne Model 300EU – Manual in PDF format online.
Manuals:
Manual Teledyne Model 300EU
Summary
M300EU SAFETY MESSAGES Addendum to M300E/EM Manual P/N 04288 SAFETY MESSAGES Your safety and the safety of others are very important. We have provided many important safety messages in this manual. Please read these messages carefully. A safety message alerts you to potential hazards that could hurt...
SAFETY MESSAGES M300EU Addendum to M300E/EM Manual P/N 04288 USER NOTES: ii 05904 Rev A
M300EU TABLE OF CONTENTS Addendum to M300E/EM Manual P/N 04288 TABLE OF CONTENTS 1. INTRODUCTION .................................................................................................................................................................... III 1.1. Reference Numbering conventio...
TABLE OF CONTENTS M300EU Addendum to M300E/EM Manual P/N 04288 10.3. Electronic Operation ..................................................................................................................................................... 53 10.3.1. Overview............................................
M300EU TABLE OF CONTENTS Addendum to M300E/EM Manual P/N 04288 Table 6-7: M300EU Hessen GAS ID List ......................................................................................................39 Table 6-8: Default Hessen Status Bit Assignments .................................................
TABLE OF CONTENTS M300EU Addendum to M300E/EM Manual P/N 04288 USER NOTES: iv 05904 Rev A
M300EU INTRODUCTION Addendum to M300EU Manual - P/N 04288 1. INTRODUCTION This addendum is based on the M300E/EM Operators Manual (P/N 04288). It is intended as a supplement to the M300E/EM manual (P/N 04288) and provides an overview of the instrument operation and specific details regarding those a...
M300EU SPECIFICATIONS, APPROVALS AND WARRANTY (Addendum to M300EU Manual - P/N 04145) 2. SPECIFICATIONS, APPROVALS AND WARRANTY 2.1. SPECIFICATIONS Table 2-1: M300EU Basic Unit Specifications Ranges User selectable to any full scale range from 0-100 ppb to 0-100 ppm Measurement Units ppb, ppm, µg/m ...
SPECIFICATIONS, APPROVALS AND WARRANTY M300EU Addendum to M300E/EM Manual P/N 04288 2.2. EPA EQUIVALENCY DESIGNATION The M300EU has not been certified by the EPA as an equivalent method at the time of this writing however it is anticipated that the M300EU will qualify as Reference Method Number EQSA...
M300EU GETTING STARTED (Addendum to M300EU Manual - P/N 04145) 3. GETTING STARTED 3.1. UNPACKING THE M300EU Unpack the M300EU as per the directions in Section 3.1 of the M300E/EM manual (P/N 04288), with the exception that there are no shipping screws. 3.2. M300EU ANALYZER LAYOUT The front panel of ...
GETTING STARTED M300EU Addendum to M300E/EM Manual P/N 04288 The pneumatic flow of the M300EU is different from the M300E/EM in two ways: • The addition of a high-flow multi-tube Nafion ® dryer. • An additional gas path that passes the sample gas though a CO scrubber used during the auto- reference ...
M300EU GETTING STARTED (Addendum to M300EU Manual - P/N 04145) 3.3.2. ANALOG OUTPUT Connections The analog outputs for the M300EU are different from those of the M300E/EM. Unlike the M300E/EM which can include options for measuring both O 2 and CO, the M300EU is a single gas analyzer (CO) and theref...
M300EU GETTING STARTED (Addendum to M300EU Manual - P/N 04145) 3.4. INITIAL OPERATION OF THE M300EU NOTE The analyzer’s cover must be installed and securely fastened to ensure that the convection oven portion of the internal layout is capable of properly creating and controlling temperatures of the ...
M300EU GETTING STARTED (Addendum to M300EU Manual - P/N 04145) 3.5. INITIAL CALIBRATION 3.5.1. PRE-CALIBRATION STABILIZATION Before initially calibrating the M300EU it must be allowed to operate for a minimum of 12 hours. After this stabilization period is complete and just prior to performing the i...
GETTING STARTED M300EU Addendum to M300E/EM Manual P/N 04288 3.5.3. BASIC CO CALIBRATION PROCEDURE The initial calibration should be carried out using the same reporting range set up as used during the analyzer’s factory calibration. This will allow you to compare your calibration results to the fac...
M300EU FREQENTLY ASKED QUESTIONS & GLOSSARY (Addendum to M300EU Manual - P/N 04145) 4. FREQENTLY ASKED QUESTIONS & GLOSSARY The information found in Chapter 4 of the M300E/EM Operators Manual (P/N 04288) is applicable to the M300EU. USER NOTES: 05514 Rev A1 13
M300EU Optional Hardware and Software (Addendum to M300EU Manual - P/N 04145) 5. OPTIONAL HARDWARE AND SOFTWARE The following table lists the optional hardware is available for the M300Ex family of analyzers. There are no additional options available for the M300EU that are not also available for th...
Optional Hardware and Software M300EU Addendum to M300E/EM Manual P/N 04288 For assistance with ordering these options, please contact the Sales department of Teledyne – Advanced Pollution Instruments at: TOLL-FREE: 800-324-5190 FAX: 858-657-9816 TEL: 858-657-9800 E-MAIL: [email protected] WEB ...
M300EU Optional Hardware and Software (Addendum to M300EU Manual - P/N 04145) 5.1.2. ZERO SPAN VALVES WITH IZS (OPT 51B) Because of the addition of the auto-reference gas path and the multi-tube Nafion ® dryer, the internal pneumatics gas flow of the M300EU is somewhat different from the M300E/EM. O...
M300EU M300EU OPERATING INSTRUCTIONS (Addendum to M300EU Manual - P/N 04145) 6. M300EU OPERATING INSTRUCTIONS 6.1. SUMMARY OF DIFFERENCES BETWEEN OPERATING THE M300EU AND THE M300E/EM ANALYZERS. For the most part the operation instruction for the M300EU are the same as those described in Chapter 6 o...
M300EU OPERATING INSTRUCTIONS M300EU Addendum to M300E/EM Manual P/N 04288 6.2. OPERATING MODES The information found in Section 6.1 of the M300E/EM Operators Manual (P/N 04288) is applicable to the M300EU with the following exception(s). The following table supersedes Table 6-2 of the M300E/EM Oper...
M300EU M300EU OPERATING INSTRUCTIONS (Addendum to M300EU Manual - P/N 04145) 6.2.1. AUTO-REFERENCE MODE (AREF) One of the most significant differences between the M300E/EM and the M300EU analyzers is the auto-reference measurement feature. In this mode, the analyzer makes special measurements and ca...
M300EU OPERATING INSTRUCTIONS M300EU Addendum to M300E/EM Manual P/N 04288 6.2.2. TEST FUNCTIONS The information found in Section 6.2.1 of the M300E/EM Operators Manual (P/N 04288) is applicable to the M300EU with the following exception(s): • The following table supersedes Table 6-2 of the M300E/EM...
M300EU M300EU OPERATING INSTRUCTIONS (Addendum to M300EU Manual - P/N 04145) 6.3. SETUP Æ RNGE: ANALOG OUTPUT REPORTING RANGE CONFIGURATION 6.3.1. PHYSICAL RANGE VERSUS ANALOG OUTPUT REPORTING RANGES Functionally, the M300EU analyzer has one hardware “physical range” that is capable of determining C...
M300EU OPERATING INSTRUCTIONS M300EU Addendum to M300E/EM Manual P/N 04288 The A1 and A2 channels output a signal that is proportional to the CO concentration of the sample gas. They can be configured: • With independent reporting ranges reporting a “single” output signal ( SNGL Mode, see Section 6....
M300EU M300EU OPERATING INSTRUCTIONS (Addendum to M300EU Manual - P/N 04145) 6.3.3. RNGE Æ MODE Æ SNGL: CONFIGURING THE M300EU ANALYZER FOR SINGLE RANGE MODE The single range mode sets a single maximum range for the both the A1 and A2 analog outputs. If the single range is selected both outputs are ...
M300EU OPERATING INSTRUCTIONS M300EU Addendum to M300E/EM Manual P/N 04288 6.3.6. SETUP Æ RNGE Æ UNIT: SETTING THE REPORTING RANGE UNIT TYPE The M300EU can display concentrations in ppb, ppm, ug/m 3 , mg/m 3 units. Changing units affects all of the COM port values, and all of the display values for ...
M300EU M300EU OPERATING INSTRUCTIONS (Addendum to M300EU Manual - P/N 04145) 6.4. SETUP Æ MORE Æ AREF: CONFIGURING AND PERFORMING AUTO-REFERENCE MEASUREMENTS 6.4.1. ADJUSTING THE A-REF MODE CYCLE TIME The auto-reference measurement feature is initiated by the M300EU at regular intervals (see Section...
M300EU OPERATING INSTRUCTIONS M300EU Addendum to M300E/EM Manual P/N 04288 6.4.2. FORCING AN AUTO-REFERENCE MEASUREMENT Sometimes it is advisable to perform an auto-reference measurement at other times such as just before calibrating the analyzer. To manually start an auto-reference measurement cycl...
M300EU OPERATING INSTRUCTIONS M300EU Addendum to M300E/EM Manual P/N 04288 6.5. SETUP Æ MORE Æ VARS: INTERNAL VARIABLES (VARS) The information found in Section 6.12 of the M300E/EM Operators Manual (P/N 04288) is applicable to the M300EU with the following exception(s): • There is no STABIL_GAS vari...
M300EU M300EU OPERATING INSTRUCTIONS (Addendum to M300EU Manual - P/N 04145) 6.6. SETUP Æ MORE Æ DIAG: USING THE DIAGNOSTICS FUNCTIONS The information found in Section 6.13 of the M300E/EM Operators Manual (P/N 04288) is applicable to the M300EU with the following exception(s): • There is no DISPLAY...
M300EU OPERATING INSTRUCTIONS M300EU Addendum to M300E/EM Manual P/N 04288 6.7. ANALOG OUTPUT CONFIGURATION 6.7.1. ANALOG I/O CONFIGURATION Because the manner in which the analog outputs are implemented differs between the M300E/EM and the M300EU, there are significant differences in the manner in w...
M300EU OPERATING INSTRUCTIONS M300EU Addendum to M300E/EM Manual P/N 04288 ANALOG OUTPUT SIGNAL TYPE AND RANGE SELECTION The information found in Section 6.13.5.2 of the M300E/EM Operators Manual (P/N 04288) is applicable to the M300EU with the following exception(s): • There are minor differences i...
M300EU M300EU OPERATING INSTRUCTIONS (Addendum to M300EU Manual - P/N 04145) 6.7.2. CALIBRATION OF THE ANALOG OUTPUTS This section replaces Section 6.13.6 of the M300E/EM Operators Manual (P/N 04288). ANALOG OUPUT calibration needs to be carried out on first startup of the analyzer (performed in the...
M300EU OPERATING INSTRUCTIONS M300EU Addendum to M300E/EM Manual P/N 04288 6.7.3. SELECTING A TEST CHANNEL FUNCTION FOR OUTPUT A4 This section replaces Section 6.13.5.5 of the M300E/EM Operators Manual (P/N 04288) The Test Functions available to be reported on analog output A4 are: Table 6-6: Test C...
M300EU M300EU OPERATING INSTRUCTIONS (Addendum to M300EU Manual - P/N 04145) To activate the TEST Channel and select a function, press: 6.7.4. HESSEN PROTOCOL The information found in Section 6.15.3 of the M300E/EM Operators Manual (P/N 04288) is applicable to the M300EU with the following exception...
M300EU OPERATING INSTRUCTIONS M300EU Addendum to M300E/EM Manual P/N 04288 • The list of Hessen status flags for the M300EU is different from that of the M300E/EM. The following table replaces Table 6-33 of the M300E/EM Operators Manual (P/N 04288). Table 6-8: Default Hessen Status Bit Assignments S...
M300EU CALIBRATION PROCEDURES (Addendum to M300EU Manual - P/N 04145) 7. CALIBRATION PROCEDURES Calibration of the M300EU should be performed according to the procedures described in Chapters 7 & 8 of the M300E/EM Manual - P/N 04288 with the following notes and exceptions: • Delivering span and ...
CALIBRATION PROCEDURES M300EU Addendum to M300E/EM Manual P/N 04288 MANUAL CALIBRATION WITH ZERO/SPAN VALVES The information found in Section 7.4 of the M300E/EM Operators Manual (P/N 04288) is applicable to the M300EU with the following exception(s). • Set the display to show the STABILITY test fun...
M300EU EPA Protocol Calibration (Addendum to M300EU Manual - P/N 04145) 8. EPA PROTOCOL CALIBRATION The information found in Chapter 8 of the M300E/EM Operators Manual (P/N 04288) is applicable to the M300EU. USER NOTES: 05514 Rev A1 43
M300EU INSTRUMENT MAINTENANCE (Addendum to M300EU Manual - P/N 04145) 9. INSTRUMENT MAINTENANCE The information found in Chapter 9 of the M300E/EM Operators Manual (P/N 04288) is applicable to the M300EU with the following exception(s): • The oven temperature should be tracked along with the other p...
M300EU THEORY OF OPERATION (Addendum to M300EU Manual - P/N 04145) 10. THEORY OF OPERATION 10.1. MEASUREMENT METHOD The information found in Section 10.1 of the M300E/EM Operators Manual (P/N 04288) is applicable to the M300EU with the following addition. It is recommended that you read that section...
THEORY OF OPERATION M300EU Addendum to M300E/EM Manual P/N 04288 The auto-reference measurement takes approximately 15 minutes. To ensure that the sample chamber of the optical bench is properly purged when switching between the sample and auto-reference measurements and vice-versa, each auto-refere...
M300EU THEORY OF OPERATION (Addendum to M300EU Manual - P/N 04145) 10.2.2. THE A-REF VALVE ASSEMBLY The auto-reference valve assembly is located next to the optical bench, at the rear of the analyzer between the Nafion ® dryer and the outer wall of the instrument (see Figure 3-1). The following tabl...
THEORY OF OPERATION M300EU Addendum to M300E/EM Manual P/N 04288 The dryer consists of a bundle of 0.030" O.D. Nafion ® tubes housed within a single large tube shell. Sample gas flows within the Nafion tubes while water vapor absorbs into the tubular membrane walls and is removed. Moisture perme...
M300EU THEORY OF OPERATION (Addendum to M300EU Manual - P/N 04145) 10.3. ELECTRONIC OPERATION 10.3.1. OVERVIEW The information found in Section 10.4.1 of the M300E/EM Operators Manual (P/N 04288) is applicable to the M300EU with the following exception(s): • This figure replaces Figure 10-9of the M3...
M300EU THEORY OF OPERATION (Addendum to M300EU Manual - P/N 04145) 10.3.2.2. Oven Heaters AC Power Configuration The two main heaters for the convection oven area of the M300EU are AC heaters. A jumper, located in line on the power connection between the relay PCA and the heaters, set the heaters in...
THEORY OF OPERATION M300EU Addendum to M300E/EM Manual P/N 04288 10.3.2.3. Status LED’s This information replaces that found in Sections 10.4.5.5 of the M300E/EM Operators Manual. • Eight LED’s are located on the analyzer’s relay board to show the current status on the various control functions perf...
M300EU THEORY OF OPERATION (Addendum to M300EU Manual - P/N 04145) 10.3.4. POWER DISTRIBUTION The information found in Section 10.4.5 of the M300E/EM Operators Manual (P/N 04288) is applicable to the M300EU with the following exception(s): • This Figure replaces Figure 10-15 of the M300E/EM Operator...
M300EU TROUBLESHOOTING & REPAIR (Addendum to M300EU Manual - P/N 04145) 11. TROUBLESHOOTING & REPAIR 11.1. GENERAL NOTES CAUTION THE OPERATIONS OUTLINED IN THIS CHAPTER MUST BE PERFORMED BY QUALIFIED MAINTENANCE PERSONNEL ONLY. PLEASE READ CHAPTER 11 OF THE M300E/EM MANUAL (P/N 04288) BEFORE...
TROUBLESHOOTING & REPAIR M300EU Addendum to M300E/EM Manual P/N 04288 11.2. FAULT DIAGNOSIS WITH WARNING MESSAGES The following Table replaces Table 11-1; of the M300E/EM Operators Manual. Table 11-1: Warning Messages - Indicated Failures WARNING MESSAGE FAULT CONDITION POSSIBLE CAUSES BENCH TEM...
TROUBLESHOOTING & REPAIR M300EU Addendum to M300E/EM Manual P/N 04288 11.2.1. FAULT DIAGNOSIS WITH TEST FUNCTIONS The following table supersedes Table 11.2 of the M300E/EM Operators Manual (P/N 04288). Table 11-2: Test Functions - Indicated Failures TEST FUNCTIONS ( As Displayed) INDICATED FAILU...
TROUBLESHOOTING & REPAIR M300EU Addendum to M300E/EM Manual P/N 04288 11.2.2. RELAY BOARD STATUS LED’S The information found in Section 11.1.4.3 of the M300E/EM Operators Manual (P/N 04288) is applicable to the M300EU with the following exception: • The following table replaces Table 11-5 of the...
M300EU TROUBLESHOOTING & REPAIR (Addendum to M300EU Manual - P/N 04145) 11.3. GAS FLOW PROBLEMS Along with the information found in Section 11.2 of the M300E/EM Operators Manual (P/N 04288), also be aware that problems with the flow of gas through the Nafion ® dryer could also be a cause of pres...
TROUBLESHOOTING & REPAIR M300EU Addendum to M300E/EM Manual P/N 04288 11.5. SUBSYSTEM CHECHOUT 11.5.1. RELAY BOARD The information found in Section 11.5.5 of the M300E/EM Operators Manual (P/N 04288) is applicable to the M300EU with the following exception: • The following table replaces Table 1...
M300EU TROUBLESHOOTING & REPAIR (Addendum to M300EU Manual - P/N 04145) 11.6. TECHNICAL ASSISTANCE If this addendum and its trouble-shooting / repair sections do not solve your problems, technical assistance may be obtained from Teledyne Instruments, Customer Service, 9480 Carroll Park Drive, Sa...
M300EU Addendum to M300E/EM Manual APPENDIX A - Version Specific Software Documentation APPENDIX A - Version Specific Software Documentation APPENDIX A-1: M300EU Software Menu Trees APPENDIX A-2: M300EU Setup Variables Available Via Serial I/O APPENDIX A-3: M300EU Warnings and Test Measurements Via ...
APPENDIX A-1: M300EU Software Menu Trees, Revision K.6 M300EU Addendum to M300E/EM Manual APPENDIX A-1: M300EU Software Menu Trees, Revision K.6 RANGE=[Value] PPM RANGE1=[Value] PPM 2 RANGE2=[Value] PPM 2 STABIL=[Value] PPM CO MEAS=[Value] MV CO REF=[Value] MV MR RATIO=[Value] AZERO RATIO=[Value]PRE...
APPENDIX A-1: M300EU Software Menu Trees, Revision K.6 M300EU Addendum to M300E/EM Manual Figure A-3: Primary Setup Menu Æ iDAS Submenu A-4 05924 Rev K.6
M300EU Addendum to M300E/EM Manual APPENDIX A-1: M300EU Software Menu Trees, Revision K.6 Figure A-4: Secondary Setup Menu Æ COMM and VARS Submenus 05924 Rev K.6 A-5
APPENDIX A-1: M300EU Software Menu Trees, Revision K.6 M300EU Addendum to M300E/EM Manual Figure A-5: Secondary Setup Menu Æ Hessen Protocol Submenu A-6 05924 Rev K.6
APPENDIX A-2: Setup Variables For Serial I/O, Revision K.6 M300EU Addendum to M300E/EM Manual APPENDIX A-2: Setup Variables For Serial I/O, Revision K.6 Table A-1: Additional or Changed Setup Variables Relevant to the M300EU, Revision K.6 SETUP VARIABLE NUMERIC UNITS DEFAULT VALUE VALUE RANGE DESCRI...
M300EU Addendum to M300E/EM Manual APPENDIX A-3: Warnings and Test Functions, Revision K.6 APPENDIX A-3: Warnings and Test Functions, Revision K.6 Table A-3: Additional or Changed Relevant to the M300EU Warning Messages, Revision K.6 NAME MESSAGE TEXT DESCRIPTION WAUTOZERO AZERO WARN 1.001 Auto-refe...
APPENDIX A-5: M300EU iDAS Parameters Revision K.6 M300EU Addendum to M300E/EM Manual APPENDIX A-5: M300EU iDAS Parameters Revision K.6 Table A-9: Additional or Changed iDAS Trigger Events for M300EU, Revision K.6 NAME DESCRIPTION AZEROW Auto-zero warning OVTMPW Internal box temperature #2/oven warni...
M300EU Addendum to M300E/EM Manual APPENDIX B - M300EU SPARE PARTS & EXPENDABLES 05925 Rev A B-1 APPENDIX B - M300EU SPARE PARTS & EXPENDABLES NOTE Use of replacement parts other than those supplied by API may result in non-compliance with European standard EN 61010-1. • 04832 – Spare Parts ...
APPENDIX B - M300EU SPARE PARTS & EXPENDABLES M300EU Addendum to M300E/EM Manual B-2 05925 Rev A USER NOTES
Teledyne Manuals
-
Teledyne 4220
Manual
-
Teledyne 311-D
Manual
-
Teledyne HPM 4/6
Manual
-
Teledyne T802
Manual
-
Teledyne 318R
Manual
-
Teledyne 9700
Manual
-
Teledyne BDS-3960
Manual
-
Teledyne C-2000
Manual
-
Teledyne GFC 7001EM
Manual
-
Teledyne 2103
Manual
-
Teledyne 6400E
Manual
-
Teledyne AX300-I
Manual
-
Teledyne 6600
Manual
-
Teledyne 9950
Manual
-
Teledyne PEM 9002
Manual
-
Teledyne HPM-2002-OBE
Manual
-
Teledyne Infrared Gas Analyzer
Manual
-
Teledyne 102E
Manual
-
Teledyne OT-3
Manual
-
Teledyne LLG
Manual