Teledyne 311-D - Manual
Teledyne 311-D – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – TABLE OF CONTENTS
- Page 4 – The differential power and digital panel meter; BATTERY CHECK; The Model 311D provides monitoring accuracy
- Page 5 – WARNING; Caution should be exercised!; SUPPORTING EQUIPMENT AND SERVICES; The customer must provide a means of controlling the
- Page 6 – The Model 311D is delivered completely assembled and ready for
- Page 7 – DO NOT ATTEMPT TO ACTUALLY TAKE A READING
- Page 8 – Positive Pressure Sampling:; When connecting the instrument to a positive; IF A FLOWING SAMPLE WAS CONNECTED TO THE MANIFOLD; If the sample is at atmospheric pressure (or; Battery Power Supply Service.; The Model 311D is for use ONLY when it is
- Page 9 – Beyond adhering to a battery recharge schedule, no; Cell; The characteristics of the Micro-Fuel Cell are similar to
- Page 10 – The Class B-2C cell employed in the Model 311D is warranted; warranty null and void.; TRANSDUCTION AND TEMPERATURE COMPENSATION
- Page 13 – EFFECT OF CO2 ON B-2C CELL LIFE
- Page 15 – DRAWING LIST; DIAGRAM
INSTRUCTION MANUAL
FOR
TRACE OXYGEN ANALYZER
MODEL 311-D
RANGES: 0-100 PPM; 0-1000 PPM; 1% AND 100%
TELEDYNE ANALYTICAL INSTRUMENTS
16830 CHESTNUT STREET
CITY OF INDUSTRY, CALIF. 91749
TELEPHONE: (626) 934-1500
FAX: (626) 961-2538
TWX: (910) 584-1887 TDYANYL COID
EASYLINK: 628-31862
Web: www.teledyne-ai.com
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
TABLE OF CONTENTS MODEL 311D 1. INTRODUCTION 1 1.1 Description 1 1.2 Method of Analysis 1 1.3 Outstanding Features 1 1.3.1 Micro-Fuel Cell 1 1.3.2 Reliable Calibration 1 1.3.3 Integral Power Supply 2 1.3.4 Accuracy and Response 2 1.3.5 Compact Packaging 3 1.3.6 Circuit Description 3 2. SUPPORTING EQ...
After the electronics have been properly zeroed (a one-time factory operation), the instrument cannot produce an output indication in the absence of oxygen; therefore, the need for a “zero” standardization gas is obviated. 1.3.3 Integral Power Supply: The differential power and digital panel meter (...
Further disassembly may be accomplished by removing the backplate assembly from its four mounting standoffs, and laying the two separated assemblies out as illustrated on the “Analyzer Wiring Diagram”. The diagram is included among the drawings at the rear of the manual. 1.3.6 Circuit Description: A...