Table of Contents:

  • Page 2 – TABLE OF CONTENTS
  • Page 4 – The differential power and digital panel meter; BATTERY CHECK; The Model 311D provides monitoring accuracy
  • Page 5 – WARNING; Caution should be exercised!; SUPPORTING EQUIPMENT AND SERVICES; The customer must provide a means of controlling the
  • Page 6 – The Model 311D is delivered completely assembled and ready for
  • Page 7 – DO NOT ATTEMPT TO ACTUALLY TAKE A READING
  • Page 8 – Positive Pressure Sampling:; When connecting the instrument to a positive; IF A FLOWING SAMPLE WAS CONNECTED TO THE MANIFOLD; If the sample is at atmospheric pressure (or; Battery Power Supply Service.; The Model 311D is for use ONLY when it is
  • Page 9 – Beyond adhering to a battery recharge schedule, no; Cell; The characteristics of the Micro-Fuel Cell are similar to
  • Page 10 – The Class B-2C cell employed in the Model 311D is warranted; warranty null and void.; TRANSDUCTION AND TEMPERATURE COMPENSATION
  • Page 13 – EFFECT OF CO2 ON B-2C CELL LIFE
  • Page 15 – DRAWING LIST; DIAGRAM
Loading the manual

INSTRUCTION MANUAL

FOR

TRACE OXYGEN ANALYZER

MODEL 311-D






RANGES: 0-100 PPM; 0-1000 PPM; 1% AND 100%











TELEDYNE ANALYTICAL INSTRUMENTS

16830 CHESTNUT STREET

CITY OF INDUSTRY, CALIF. 91749

TELEPHONE: (626) 934-1500

FAX: (626) 961-2538

TWX: (910) 584-1887 TDYANYL COID

EASYLINK: 628-31862

Web: www.teledyne-ai.com

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TABLE OF CONTENTS

TABLE OF CONTENTS MODEL 311D 1. INTRODUCTION 1 1.1 Description 1 1.2 Method of Analysis 1 1.3 Outstanding Features 1 1.3.1 Micro-Fuel Cell 1 1.3.2 Reliable Calibration 1 1.3.3 Integral Power Supply 2 1.3.4 Accuracy and Response 2 1.3.5 Compact Packaging 3 1.3.6 Circuit Description 3 2. SUPPORTING EQ...

Page 4 - The differential power and digital panel meter; BATTERY CHECK; The Model 311D provides monitoring accuracy

After the electronics have been properly zeroed (a one-time factory operation), the instrument cannot produce an output indication in the absence of oxygen; therefore, the need for a “zero” standardization gas is obviated. 1.3.3 Integral Power Supply: The differential power and digital panel meter (...

Page 5 - WARNING; Caution should be exercised!; SUPPORTING EQUIPMENT AND SERVICES; The customer must provide a means of controlling the

Further disassembly may be accomplished by removing the backplate assembly from its four mounting standoffs, and laying the two separated assemblies out as illustrated on the “Analyzer Wiring Diagram”. The diagram is included among the drawings at the rear of the manual. 1.3.6 Circuit Description: A...