Manual: 153-082010_HPM 4-6 Vacuum Gauge Page 2 of 12 Manual Print History The print history shown below lists the printing dates of all revisions and addenda created for this manual. The revision level letter increases alphabetically as the manual undergoes subsequent updates. Addenda, which are rel...
Page 3 - Table of Contents
Manual: 153-082010_HPM 4-6 Vacuum Gauge Page 3 of 12 Table of Contents 1.0 QUICK START INSTRUCTIONS................................................................................................................... 4 2.0 SPECIFICATIONS ...................................................................
Page 4 - Quick Start Instructions
Manual: 153-082010_HPM 4-6 Vacuum Gauge Page 4 of 12 1. Unpack unit and insure battery is installed 2. Connect thermocouple tube. 3. Slide switch to DV4 or DV6 position according to tube type 4. Indicated pressure is displayed on LCD display. 5. Slide switch to center/off position when not in use. 1...
Page 5 - Specifications
Manual: 153-082010_HPM 4-6 Vacuum Gauge Page 5 of 12 Operating Range .................................................................... DV-4 - 0.01 - 20 Torr (.01 to 20 mbar) ........................................................................................... DV-6 - 0.001 – 1 Torr (.001 to ...
Manual: 153-082010_HPM 4-6 Vacuum Gauge Page 6 of 12 3.1. Receiving Inspection Unpack unit and inspect all items for obvious signs of damage. Immediately advise Teledyne Hastings and the carrier of any suspected damage. In the unlikely event that items need to be returned, first obtain an RMA (Retur...
Page 7 - General Information
Manual: 153-082010_HPM 4-6 Vacuum Gauge Page 7 of 12 Operation of the Hastings gauge sensor (DV-4 or DV-6) is based on a low voltage AC bridge that heats a noble metal thermopile. A change in pressure in the gauge tube alters the molecular collision rate and therefore the thermal conduction of the g...
Page 9 - Calibration in a Vacuum System; Calibration with a Reference Tube; Calibration
Manual: 153-082010_HPM 4-6 Vacuum Gauge Page 9 of 12 5.1. Calibration in a Vacuum System 1 Install a DV-4 or DV-6 sensor in your vacuum system and evacuate vacuum chamber to a pressure less than 1.00E-04 Torr. NOTE: Refer to Fig 3 for locations of calibration pots. Adjust only the pot that correspon...
Page 11 - Authorized Maintenance; Maintenance
Manual: 153-082010_HPM 4-6 Vacuum Gauge Page 11 of 12 6.1. Authorized Maintenance The HPM 4/6 Power Supply/Display does not require maintenance other than routine battery replacement and calibration. Note: A low battery will be indicated by “LOBAT” appearing in lower left corner of LCD display. In t...
Manual: 153-082010_HPM 4-6 Vacuum Gauge Page 12 of 12 7.1. Warranty Repair Policy Hastings Instruments warrants this product for a period of one year from the date of shipment to be free from defects in material and workmanship. This warranty does not apply to defects or failures resulting from unau...