Page 3 - Foreword; Return Authorization Number; This will aid in the prompt repair and return of the; Contact Information
Foreword This instruction manual is designed to help you gain a thorough understanding of theoperation of the equipment. Teledyne Isco recommends that you read this manualcompletely before placing the equipment in service. Although Teledyne Isco designs reliability into all equipment, there is alway...
Page 5 - iii; Table of Contents; Section 1 Introduction
iii 2103 Modem Module Table of Contents Section 1 Introduction 1.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11.2 Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 6 - iv; Appendix A Replacement Parts; List of Figures
2103 Modem ModuleTable of Contents iv 5.3.2 Reactivating the Desiccant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 5.4 Hydrophobic Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-35.5 O-Rings . . . . . ....
Page 7 - 1 0 3 c C e l l u l a r; Product Description; Flowlink
1-1 2103 Modem Module Section 1 Introduction 1.1 Introduction This instruction manual is designed to help you gain a thoroughunderstanding of the operation of the 2103 and 2103c ModemModules. Teledyne Isco recommends that you read this manualcompletely before placing the equipment into service. Info...
Page 8 - Figure 1-1 2103 Modem Components - Top View; Table 1-1 2103 Modem Module Components - Top View; Name
2103 Modem ModuleSection 1 Introduction 1-2 1.3 Identifying Module Components Figures 1-1 and 1-2 identify the key components of the 2103Modem. Figure 1-1 2103 Modem Components - Top View 1 3 4 5 6 2 Table 1-1 2103 Modem Module Components - Top View Item No. Name Description 1 Communication Connecto...
Page 9 - Table 1-2 2103 Modem Module Components - Bottom View
2103 Modem Module Section 1 Introduction 1-3 Figure 1-2 2103 Modem Components - Bottom View 2 1 3 4 5 Table 1-2 2103 Modem Module Components - Bottom View Item No. Name Description 1 Communication Connector This connects the 2103 Modem to other 2100 Series modules in the stack and is used to transfe...
Page 11 - Table 1-5 2103 Communication Connector Pins; Pin
2103 Modem Module Section 1 Introduction 1-5 Figure 1-3 2103 Communication Connector Pins A B C D E F G Table 1-5 2103 Communication Connector Pins (2103 only) Pin Name Description A LONA Neuron differential transceiver Data A B LONB Neuron differential transceiver Data B C VIN+ Positive power suppl...
Page 12 - CAUTION; Warnings indicate potentially hazardous conditions. If you
2103 Modem ModuleSection 1 Introduction 1-6 Figure 1-4 2103 Modem Cable Connector 1.4 Safety Symbols and Hazard Alerts This icon identifies a general hazard and is accompaniedwith details about the hazard. The instruction manualidentifies the hazardous condition and any steps nec- essary to correct ...
Page 13 - Section 1 Introduction; Technical Service
2103 Modem Module Section 1 Introduction 1-7 1.5 Technical Service A l t h o u g h Te l e d y n e I s c o d e s i g n s r e l i a b i l i t y i n t o a l l o f i t se q u i p m e n t , t h e r e i s a lway s t h e p o s s i b i l i t y o f a m a l fu nc t i o noccurring. You can use this manual to h...
Page 15 - Section 2 Installation and Operation; Instructions; If there is any evidence that any items may have been; WARNING; Avoid hazardous practices! If you use these instruments in; WARNING; The installation and use of this product may subject you
2-1 2103 Modem Module Section 2 Installation and Operation 2.1 Unpacking Instructions When the system arrives, inspect the contents for any damage. Ifthere is damage, contact the delivery company and Teledyne Isco(or its agent) immediately. WARNING If there is any evidence that any items may have be...
Page 16 - Follow the instructions below to install your 2103 Modem.; Unlocking; Latches will “click” when they are fully locked and unlocked.; Connectors; Caps; PUSH ON; and; PULL OFF; . Do not rotate the caps to; Note
2103 Modem ModuleSection 2 Installation and Operation 2-2 hazardous environments that can prove fatal for those unpre-pared. These spaces are governed by OSHA 1910.146 and requirea permit before entering. 2.3 Installation Follow the instructions below to install your 2103 Modem. 2.3.1 Latches - Lock...
Page 17 - Section 2 Installation and Operation
2103 Modem Module Section 2 Installation and Operation 2-3 2.3.3 Stacking Modules The 2103 Modem Module can be located anywhere within a stackof up to three 2100 Series networked modules. It will draw itspower from the battery module located in the stack. To connect the 2103 with a 2100 Series modul...
Page 18 - service is subject to state tariffs.; Changes in Attestation Procedure for Plugs and Jacks; If any of your telephone equipment is not
2103 Modem ModuleSection 2 Installation and Operation 2-4 service is subject to state tariffs. Changes in Attestation Procedure for Plugs and Jacks Isco Inc. attests that the network interface plugs or jacks usedon this equipment comply with and will continue to comply withthe mechanical requirement...
Page 19 - Connection; Figure 2-1 Connecting the Modem Cable; the Modem Cable
2103 Modem Module Section 2 Installation and Operation 2-5 2.4.1 Modem Cable Connection After you have installed the 2103 on the stack, you need to attachthe modem cable so the module can be connected to a phone line. Remove the connector cap from the 5-pin circular modem cableconnector on the right...
Page 20 - Figure 2-3 Flowlink Connect Screen
2103 Modem ModuleSection 2 Installation and Operation 2-6 2.5 Connecting to Flowlink After the 2103 is installed and the modem cable connected, youneed to configure the 2103 in Isco’s Flowlink software. Note The 2103 Modem requires Flowlink 4.13 or later. Earlier ver-sions do not support the Modem. ...
Page 21 - Capability
2103 Modem Module Section 2 Installation and Operation 2-7 2.6 Pushed Data Capability The module can automatically send data via the internet to adesignated server running Isco Flowlink Pro software, using1xRTT packet-switched data transmission (2103c) or landline(2103). The user-specified primary d...
Page 23 - Section 3 2103c Cellular Modem Module; Compatibility; • The; external, magnetic mount
3-1 2103 Modem Module Section 3 2103c Cellular Modem Module 3.1 Overview The 2103c Modem (part #68-2000-033 with whip antenna; part#68-2000-030 with buried antenna) is a portable data retrievalu n i t d e s i g n e d t o t r a n s m i t d a t a f r o m I s c o ’ s 2 1 0 0 S e r i e sOpen-Channel flo...
Page 27 - Section 4 Modbus Protocol; registers
4-1 2103 Modem Module Section 4 Modbus Protocol Sections 4.1 through 4.5 give an overview of the basic capabilitiesand operation of Modbus protocol as it applies to Isco 2100 Seriesflow modules. For a Glossary of Terms and Common Acronyms, see sections 4.4and 4.5. For Modbus technical specifications...
Page 28 - Communication; • The model numbers of the modules
2103 Modem ModuleSection 4 Modbus Protocol 4-2 By accessing these registers you can obtain the current value ofwhatever parameter you desire. The reading(s) can then be dis-played or stored wherever you designate as a destination; forexample, a process control computer. Note Level, flow, velocity, a...
Page 29 - Section 4 Modbus Protocol; The user requests data through Process Control.
2103 Modem Module Section 4 Modbus Protocol 4-3 4.3 Configurations A variety of configurations can be made with Modbus, eitherthrough direct connection or through a modem. In the example shown in Figure 4-1, you are direct-connecting aserver PC to two individual 2150s through Modbus, using theCOM po...
Page 30 - Glossary of Terms
2103 Modem ModuleSection 4 Modbus Protocol 4-4 5. OPC connects to the 2150 stack through the cable (direct connection), takes register data from the specified 2150, and populates the OPC server's holding index. 6. Process Control takes data from the OPC server's holding index and gives data to the u...
Page 32 - Register Specifications; The Modbus ASCII address is used to index the data by modules.; Table 4-1 Modbus ASCII Address 1 Register Definitions; Register
2103 Modem ModuleSection 4 Modbus Protocol 4-6 4.6 Register Specifications All numbers in the Modbus registers are stored most significantbyte first. If the polling device has a byte ordering of least signif-icant byte first (an Intel-based PC, for example), the bytes willneed to be reversed after t...
Page 35 - Table 4-3 Measurement Parameters by Model Number*
2103 Modem Module Section 4 Modbus Protocol 4-9 238-243 Analog channel 5 time record Time Read 250,251 Analog channel 6 4-byte float 0-100 percent Read 252 Analog channel 6 status code 16-bit integer Read 253-258 Analog channel 6 time record Time Read 265,266 Analog channel 7 4-byte float 0-100 perc...
Page 37 - Section 5 Maintenance; Overview; E x p e r i e n c e
5-1 2103 Modem Module Section 5 Maintenance 5.1 Maintenance Overview This section explains the maintenance requirements of the 2103Modem. The 2103 Modem is designed to perform reliably in adverse con-ditions with a minimal amount of routine service requirements.To keep your system working properly, ...
Page 38 - Use a vented oven in a well ventilated room.
2103 Modem ModuleSection 5 Maintenance 5-2 5.3 Desiccant The 2103 Modem uses desiccant to protect the internal compo-nents from moisture damage. The cartridge is filled with indi-c a t i n g s i l i c a g e l , w h i c h i s b l u e o r y e l l o w w h e n d r y. A s t h edesiccant becomes saturated...
Page 39 - Hydrophobic Filter; How to Obtain Service
2103 Modem Module Section 5 Maintenance 5-3 Silica gel To reactivate the silica gel desiccant, pour the spent desiccanti n t o a h e a t r e s i s t a n t c o n t a i n e r. N e v e r h e a t t h e c a r t r i d g eassembly; it will melt. Heat the silica gel in a vented convection oven at 212° to 35...
Page 41 - Appendix A Replacement Parts; A.1 Replacement Parts
A-1 2103 Modem Module Appendix A Replacement Parts A.1 Replacement Parts Replacement parts are called out in the following pages. Refer tothe call-out in the adjacent table to determine the part numberfor the item. Replacement parts can be purchased by contacting TeledyneIsco’s Customer Service Depa...
Page 42 - Parts
2103 Modem ModuleAppendix A Replacement Parts A-2 A.1.1 2103 Replacement Parts
Page 53 - Appendix B Accessories; B.2 General Accessories
B-1 2103 Modem Module Appendix B Accessories B.1 How to Order Accessories can be purchased by contacting Teledyne Isco’s Cus-tomer Service Department. Teledyne Isco, Inc. Customer Service Dept.P.O. Box 82531Lincoln, NE 68501 USA Phone: (800) 228-4373 (402) 464-0231 FAX: (402) 465-3022 E-mail: IscoIn...
Page 55 - Appendix C Material Safety Data Sheets
C-1 2103 Modem Module Appendix C Material Safety Data Sheets C.1 Overview This appendix to the manual provides Material Safety DataSheets for the desiccant used by the 2103 Modem. Teledyne Isco cannot guarantee the accuracy of the data. Specificquestions regarding the use and handling of the product...
Page 56 - Material Safety Data Sheet; Section 1 - Material Identification and Information; Section 2 - Physical/Chemical Characteristics; Section 4 - Reactivity Hazard Data
2103 Modem ModuleAppendix C Material Safety Data Sheets C-2 *Optional Indicating Silica Gel Material Safety Data Sheet Indicating Silica Gel Identity (Trade Name as Used on Label) Manufacturer: MULTISORB TECHNOLOGIES, INC. (formerly Multiform Desiccants, Inc.) MSDS Number* : M75 Address: 325 Harlem ...
Page 57 - Section 5 - Health Hazard Data
2103 Modem Module Appendix C Material Safety Data Sheets C-3 *Optional Indicating Silica Gel Page 2 Section 5 - Health Hazard Data PRIMARY ROUTES I nhalation Ingestion OF ENTRY Skin Absorption Not Hazardous CARCINOGEN NTP OSHA LISTED IN IARC Monograph Not Listed HEALTH HAZARDS Acute May cause eye, s...
Page 58 - MATERIAL SAFETY DATA SHEET; Section 1 – Product and Company Information; Section 3 – Hazard Identification
2103 Modem ModuleAppendix C Material Safety Data Sheets C-4 MATERIAL SAFETY DATA SHEET Effective Date March 8, 2005 MSDS Number M163 Section 1 – Product and Company Information Product Name: Silica gel, indicating, yellow Product Use: Desiccant, absorbent Grades: Silica gel, indicating Synonyms: Amo...
Page 59 - Section 4 – First Aid Measures
2103 Modem Module Appendix C Material Safety Data Sheets C-5 Section 4 – First Aid Measures Eyes: Rinse the eyes well with water while lifting the eye lids. If irritation persists, consult a physician. Skin: Wash affected area with soap and water. Ingestion: Ingestion is unlikely, this material will...
Page 60 - Section 8 – Exposure Controls/Personal Protection; Section 9 – Physical and Chemical Properties
2103 Modem ModuleAppendix C Material Safety Data Sheets C-6 Section 8 – Exposure Controls/Personal Protection Engineering Controls: Use exhaust ventilation to keep the airborne concentrations below the exposure limits. Respiratory Protection: Use NIOSH approved respirator when the air quality levels...
Page 61 - Section 11 – Toxicological Information; Section 12 – Ecological Information; Section 14 – Transportation Information
2103 Modem Module Appendix C Material Safety Data Sheets C-7 Section 11 – Toxicological Information This product and its components are not listed on the NTP or OSHA Carcinogen lists. Animal Toxicology Tests for DOT Hazard classification ( Tests Conducted on finely ground silica gel) 1 - hour LC 50 ...
Page 62 - Section 16 – Other Information
2103 Modem ModuleAppendix C Material Safety Data Sheets C-8 Section 16 – Other Information HMIS – Hazardous Materials Identification System HMIS Rating HealthFlammabilityReactivity 000 0 - minimal hazard, 1 - slight hazard, 2 - moderate hazard, 3 - serious hazard, 4 - severe hazard This MSDS was pre...
Page 63 - CE Declar; DECLARATION OF CONFORMITY; Standard Description
Compliance Statements CE Declar ati on of Conf orm ity DECLARATION OF CONFORMITY Application of Council Directive: 89/336/EEC – The EMC Directive 73/23/EEC – The Low Voltage Directive Manufacturer's Name: Teledyne Isco, Inc. Manufacturer's Address: 4700 Superior, Lincoln, Nebraska 68504 USA Mailing ...
Page 67 - Return Authorization
Teledyne Isco One Year Limited Factory Service Warranty * Teledyne Isco warrants covered products against failure due to faulty parts or workmanship for a period of one year (365 days) from their shipping date, or from the date of installation by an authorized Teledyne Isco Service Engineer, as may ...