Teledyne OT-3 - Manual

Teledyne OT-3

Teledyne OT-3 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
Page: / 50

Table of Contents:

  • Page 2 – Teledyne Analytical Instruments; Copyright © 2000 Teledyne Analytical Instruments
  • Page 3 – Specific Model Information; The instrument for which this manual was supplied may; Instrument Serial Number:
  • Page 4 – Important Notice; Symbol
  • Page 5 – This manual provides information designed to guide you through
  • Page 6 – Table of Contents
  • Page 8 – List of Figures
  • Page 9 – Introduction; Main Features of the Analyzer
  • Page 10 – Front Panel Description; Operation
  • Page 12 – Rear Panel Description; Installation; Power Connection AC version:; Maintenance
  • Page 14 – Operational Theory
  • Page 15 – The Micro-fuel Cell is made of extremely inert plastic (which can
  • Page 17 – In order to state the amount of oxygen present in the sample as a
  • Page 18 – The signal processing uses an Intel
  • Page 19 – Figure 2-3 is a block diagram of the signal processing electronics
  • Page 21 – Unpacking the Analyzer
  • Page 22 – Location and Mounting; MUST ALLWAYS FACE; Electrical Connections
  • Page 23 – Figure 3-1: Electrical Connectors for AC Control Unit
  • Page 24 – The alarm relay circuits are designed for failsafe operation. In
  • Page 27 – Vent connection
  • Page 28 – Note: Check the front of this manual for any additional
  • Page 29 – Installation Checklist
  • Page 31 – Once the analyzer has been mounted, the gas lines connected and
  • Page 32 – Using the Function and Data Entry Buttons; Note: The HI Range setpoint MUST be set at a higher
  • Page 33 – Setting the Alarm Setpoints
  • Page 36 – Selecting a Fixed Range or Autoranging; Note: If the concentration exceeds 9999 ppm oxygen, the; Preliminary—If not already done:; Note: This procedure requires a suitable span gas with pressure
  • Page 37 – Note: If the analyzer output goes above the high alarm setpoint; Displaying Percent & PPM on the LED Display
  • Page 39 – Aside from normal cleaning and checking for leaks at the gas; Replacing the Fuse; When a fuse blows, check first to determine the cause, then replace; AC Units; The fuse receptacle is located in the power cord receptacle
  • Page 40 – Sensor Installation or Replacement
  • Page 41 – READ THE SECTION; CELL WARRANTY; After replacing the Micro-fuel Cell, the analyzer must be
  • Page 42 – The cell should come out
  • Page 43 – Note that the warranty period begins on the date of shipment. The
  • Page 44 – Appendix; Specifications; : Two user selectable ranges can be set
  • Page 45 – Spare Parts List; QTY; Regulator; Orders for replacement parts should include the part; TELEDYNE ELECTRONIC TECHNOLOGIES; Analytical Instruments
  • Page 46 – Reference Drawing
  • Page 47 – Index
Loading the manual

Trace Oxygen Analyzer

Teledyne Analytical Instruments

i

OPERATING INSTRUCTIONS FOR

MODEL OT-3

MODEL OT-3

Trace Oxygen Analyzer

DANGER

Toxic gases and or flammable liquids may be present in this monitoring system.

Personal protective equipment may be required when servicing this instrument.

Hazardous voltages exist on certain components internally which may persist
for a time even after the power is turned off and disconnected.

Only authorized personnel should conduct maintenance and/or servicing.
Before conducting any maintenance or servicing, consult with authorized
supervisor/manager.

P/N M74173
10/28/2001
ECO#

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Teledyne Analytical Instruments; Copyright © 2000 Teledyne Analytical Instruments

Model OT-3 Teledyne Analytical Instruments ii Copyright © 2000 Teledyne Analytical Instruments All Rights Reserved. No part of this manual may be reproduced, transmitted, transcribed,stored in a retrieval system, or translated into any other language or computer language inwhole or in part, in any f...

Page 3 - Specific Model Information; The instrument for which this manual was supplied may; Instrument Serial Number:

Trace Oxygen Analyzer Teledyne Analytical Instruments iii Specific Model Information The instrument for which this manual was supplied may incorporate one or more options not supplied in the standard instrument.Commonly available options are listed below, with check boxes. Anythat are incorporated i...

Page 4 - Important Notice; Symbol

Model OT-3 Teledyne Analytical Instruments iv Important Notice Model OT-3 complies with all of the requirements of the Commonwealth of Europe (CE) for Radio Frequency Interference,Electromagnetic Interference (RFI/EMI), and Low Voltage Directive(LVD). The following International Symbols are used thr...

Other Teledyne Models

All Teledyne Other