Page 2 - INDEX; EN
2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS ..................................................................................................................... 3 CHARACTERISTICS .............................................................................................................................
Page 3 - RECOMMENDATIONS AND SUGGESTIONS; INSTALLATION; USE; MAINTENANCE
EN 3 3 RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance. INSTALLATION • The manufacturer will not be held liable for any damages resulting f...
Page 4 - CHARACTERISTICS; Components
EN 4 4 CHARACTERISTICS Components Ref. Q.ty Product components 1 1 Cooker hood with control unit, lights, blower unit, filters 2.1 1 Upper chimney 2.2 1 Lower chimney 8 1 Air outlet grid 9 1 Reducer flange Ø 150-120 10 1 Damper 16 1 Cover for recycling version Ref. Q.ty Installation components 7.2.1...
Page 5 - Dimensions
Page 6 - Wall drilling and bracket fixing
EN 6 6 INSTALLATION Wall drilling and bracket fixing 11a 1 1 11 12a 11 12a 3 292 292 960 X 1÷2 7.2.1 368 743 As a first step, proceed with the following drawings: • a vertical line up to the ceiling or up to the upper limit, at the centre of the area in which the hood is to be fitted; • a horizontal...
Page 7 - Hood body mounting; Attention: the upper panel stops if any barrier occurs in its; way during the panel opening or closing. To open the panel; Connections; DUCTED VERSION AIR EXHAUST SYSTEM
EN 7 7 Hood body mounting • Firstly, it is necessary to adjust the two Vr- screws of the 11a- brackets, at minimun ( B ). • Hang the hood body on the two brackets 11a . • Connect the hood to the mains supply by means of a bipolar switch with at least 3 mm contact gap. • Press the “ A ”-key for one s...
Page 8 - RECYCLING VERSION AIR OUTLET; ELECTRICAL CONNECTION; Chimney assembly; Upper exhaust Chimney
EN 8 8 RECYCLING VERSION AIR OUTLET To install the hood in recycling version, the optional charcoal filter kit must be purchased. • Remove the chimney angle bracket. • Screw the filter cover onto the air outlet, using four screws 12c (2.9 x 12.5). • Fix the air outlet grid 8 on the recirculation air...
Page 9 - Control panel
EN 9 9 USE Control panel B A D C E G F I H L Button Function Display A Door Closed: Press and hold for approximately 2 Sec-onds to open the door and turn the motor on at the last speed set. Door Open: Press briefly to turn the motor Off or On. Displays the set speed. B Decrease the working speed. Th...
Page 10 - REMOTE CONTROL; Courtesy light; Activates/deactivates
EN 1 10 REMOTE CONTROL The appliance can be controlled using a remote control powered by a 1.5 V carbon-zinc alkaline batteries of the standard LR03-AAA type (not included). • Do not place the remote control near to heat sources. • Used batteries must be disposed of in the proper manner. Remote cont...
Page 11 - Metal grease filters; Alarm reset
EN 1 11 MAINTENANCE Metal grease filters Filters can be washed in the dish machine. They need to be washed when Drop- sign appears on the display or in any case every 2 months, or even more frequently in case of particularly intensive use of the hood. Alarm reset • Press the G –key for at least 2 se...
Page 12 - Activation of the alarm signal; Lighting; LIGHT REPLACEMENT
EN 1 12 Charcoal filter (recycling version) This filter cannot be washed or regenerated. It must be replaced when the C appears on the display or at least once every 4 months. The filter saturation alarm has to be activated already before. Activation of the alarm signal • In the recycling version ho...
Page 13 - Replacing the fuser; • The fuser is placed up on the right side. Turn the
EN 1 13 Replacing the fuser • The fuser is placed up on the right side. Turn the fuser holder as indicated. Replace the fuser with one having the same features.