Page 2 - Caution; What You Need to Get Started; Cautions
NI TB-2709 Installation Guide 2 ni.com The nine SMB connectors on the TB-2709 allow you to easily connect analog input signals to your National Instruments device. The 14-pin I/O connector located on the bottom of the TB-2709 allows access to digital signals. Caution The TB-2709 is not designed for ...
Page 3 - not; Installation
© National Instruments Corporation 3 NI TB-2709 Installation Guide Do not substitute parts or modify equipment. Because of the danger of introducing additional hazards, do not install unauthorized parts or modify the device. Return the device to National Instruments for service and repair to ensure ...
Page 4 - DAQ Getting Started Guide; Signal Descriptions
NI TB-2709 Installation Guide 4 ni.com To connect the terminal block to the PXI module I/O connector, refer to Figure 2 as you complete the following steps: 1. Install the PXI module into the chassis and tighten the two module screws. You must install the PXI device before connecting the TB-2709. Re...
Page 5 - S Series User; Measuring Floating Signals
© National Instruments Corporation 5 NI TB-2709 Installation Guide Figure 4. NI TB-2709 Block Diagram For more detailed descriptions of these signals, refer to the S Series User Manual . Additional signal configuration information is available in Measurement & Automation Explorer (MAX). To acces...
Page 6 - Measuring Ground-Referenced Signals; S Series User Manual; Cabling Options; Configuration; Floating Source
NI TB-2709 Installation Guide 6 ni.com Measuring Ground-Referenced Signals It is possible to set the switch on the TB-2709 to either the floating or ground-referenced source position to measure ground-referenced signals. However, for best results, use the OFF (ground-referenced source) switch positi...
Page 7 - Pin Number
© National Instruments Corporation 7 NI TB-2709 Installation Guide conductors on the other end. The pigtail conductors on the cable assembly can be used to terminate digital signals to the connector(s) your application requires. Figure 5 and Table 3 list the pin assignments and wiring information ne...
Page 8 - Specifications
NI TB-2709 Installation Guide 8 ni.com Table 4 lists the National Instruments cables available for connecting the TB-2709 to both analog and digital user signals. Specifications This section lists the specifications of the TB-2709. These specifications are typical at 25 °C unless otherwise specified...
Page 9 - Physical; Dimensions; Shock and Vibration; Random vibration; Environment; The NI TB-2709 is intended for indoor use only.
© National Instruments Corporation 9 NI TB-2709 Installation Guide Physical Dimensions Height.............................................. 10.7 × 8.6 × 2.0 cm (4.2 × 3.4 × 0.8 in.) Weight ............................................. 144.6 g (5.1 oz) I/O connectors 68-position SCSI-II type ...........
Page 10 - Safety; Note; in the Certification column.; Waste Electrical and Electronic Equipment (WEEE); EU Customers; Where to Go for Support; you have access to everything from
NI TB-2709 Installation Guide 10 ni.com Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1, CSA 61010-1 Note For UL and other safety certifications...