National Instruments NI PXI-5621 - Manual

National Instruments NI PXI-5621

National Instruments NI PXI-5621 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
Page: / 9

Table of Contents:

  • Page 2 – VSWR; Frequency; Internal sample clock; Offset
  • Page 3 – Amplitude
  • Page 6 – Phase; DDC
  • Page 7 – Triggering; nominal; Calibration
  • Page 8 – Environmental Specifications; Operating environment; Power Requirements
  • Page 9 – Electromagnetic Compatibility; Note; Declaration of Conformity; at; Dimensions; CE Mark Compliance; Conductive Immunity; , the spurious response
Loading the manual

©

2002 National Instruments Corp. All rights reserved.

National Instruments™, NI™, and ni.com™ are trademarks of National Instruments Corporation. Product and company
names mentioned herein are trademarks or trade names of their respective companies. For patents covering
National Instruments products, refer to the appropriate location:

Help»Patents

in your software, the

patents.txt

file

on your CD, or

ni.com/patents

.

October 2002

323398B-01

NI PXI-5621 S

PECIFICATIONS

High-Speed Digitizer

The NI PXI-5621 is a DC-coupled 64 MS/s 14-bit high-speed digitizer.
Except for its DC coupling, the PXI-5621 is functionally identical to the
PXI-5620. Refer to the

NI PXI-562x User Manual

for instructions on

installing and using your NI PXI-5621.

The NI PXI-5621 specifications are warranted at 0–50

°

C ambient unless

otherwise specified, and include a 10 minute warm-up time from ambient
conditions.

General Specifications

Number of channels ............................... 1

Resolution .............................................. 14 bits

Sample rate range ................................... 1 kS/s to 64 MS/s

Onboard memory

Not using DDC ............................... 32 MS

Using DDC (complex data) ............ 16 MS

Input

Signal level

Nominal .......................................... 0 dBm (±0.316 V

p

)

Full-scale ......................................... +10 dBm (±1.000 V

p

)

Max with dither enabled ................. +8 dBm (±0.794 V

p

)

Non-operating

Max input level ........................ +20 dBm (±3.16 V

p

)

Max DC input voltage ............. ±3.0 V

Input impedance ..................................... 50

nominal

Coupling ................................................. DC

ni.com

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - VSWR; Frequency; Internal sample clock; Offset

NI PXI-5621 Specifications 2 ni.com DC offset.................................................±1 mV (calibrated) Analog bandwidth (–3 dB range) ...........0 Hz to 36 MHz Amplitude accuracy ................................±0.5 dB VSWR 0–25 MHz ........................................<1.5:1 25–32 M...

Page 3 - Amplitude

© National Instruments Corporation 3 NI PXI-5621 Specifications Amplitude Figure 1. Noise Density (Dither Disabled, Input Terminated) Average noise density(dither off) .............................................. < –129 dBm/Hz Signal-to-noise ratio 9 dBm signal, full bandwidth .......... >62...

Page 6 - Phase; DDC

NI PXI-5621 Specifications 6 ni.com Phase Figure 4. Group Delay versus Frequency Group delay variation(5–25 MHz) ............................................9 ns pk–pk Group delay variation(0.5–30 MHz) .........................................26 ns pk–pk DDC Decimation rate.............................