Page 2 - Note; Safety Guidelines
NI 9217 Operating Instructions and Specifications 2 ni.com This doc u ment describes how to u se the National Instr u ments 9217 and incl u des specifications and terminal assignments for the NI 9217. Visit ni.com/info and enter rd s oftwarever s ion to determine which software yo u need for the mod...
Page 3 - Hot Surface; Safety Guidelines for Hazardous Voltages; Caution; Caution; not
© National Instruments Corp. 3 NI 9217 Operating Instructions and Specifications Hot Surface This icon denotes that the component may be hot. To u ching this component may res u lt in bodily inj u ry. Safety Guidelines for Hazardous Voltages If hazardo u s voltages are connected to the mod u le, tak...
Page 4 - Safety Guidelines for Hazardous Locations
NI 9217 Operating Instructions and Specifications 4 ni.com Fig u re 1 shows the NI 9939 connector backshell. Figure 1. NI 9939 Connector Backshell Safety Guidelines for Hazardous Locations The NI 9217 is s u itable for u se in Class I, Division 2, Gro u ps A, B, C, D, T4 hazardo u s locations; Class...
Page 6 - Special Conditions for Hazardous Locations Use in Europe
NI 9217 Operating Instructions and Specifications 6 ni.com Special Conditions for Hazardous Locations Use in Europe This eq u ipment has been eval u ated as EEx nC IIC T4 eq u ipment u nder DEMKO Certificate No. 03 ATEX 0324020X. Each mod u le is marked II 3G and is s u itable for u se in Zone 2 haz...
Page 10 - Specifications
NI 9217 Operating Instructions and Specifications 10 ni.com If yo u are u sing a 4-wire RTD, connect EX to the positive lead of the RTD. If yo u are u sing a 3-wire RTD, do not connect the RTD to the EX terminal. For the best meas u rement res u lts when u sing the NI 9217 with a 3-wire RTD, u se eq...
Page 11 - Wiring for High-Vibration Applications
© National Instruments Corp. 11 NI 9217 Operating Instructions and Specifications Wiring for High-Vibration Applications If an application is s u bject to high vibration, National Instr u ments recommends that yo u either u se ferr u les to terminate wires to the detachable screw-terminal connector ...
Page 12 - Sleep Mode
NI 9217 Operating Instructions and Specifications 12 ni.com Sleep Mode This mod u le s u pports a low-power sleep mode. S u pport for sleep mode at the system level depends on the chassis that the mod u le is pl u gged into. Refer to the chassis man u al for information abo u t s u pport for sleep m...
Page 13 - Input Characteristics
© National Instruments Corp. 13 NI 9217 Operating Instructions and Specifications Specifications The following specifications are typical for the range – 40 to 70 °C u nless otherwise noted. All voltages are relative to COM u nless otherwise noted. All specifications given in °C are specific to 100 ...
Page 14 - Measured Value
NI 9217 Operating Instructions and Specifications 14 ni.com Conversion time High-resol u tion mode................. 200 ms per channel, 800 ms total for all channels High-speed mode........................ 2.5 ms per channel, 10 ms total for all channels Temperat u re acc u racy (incl u ding noise) ...
Page 16 - tion filter response
NI 9217 Operating Instructions and Specifications 16 ni.com High-resol u tion filter response 1,2 1 This image is provided co u rtesy of Linear Technology Corp. 2 High-speed filter response has the same characteristics as the high-resol u tion filter response except that the first notch is at 14 kHz...
Page 17 - Power Requirements
© National Instruments Corp. 17 NI 9217 Operating Instructions and Specifications Overvoltage protection ..................... ±30 V between inp u ts MTBF ............................................... 891,597 ho u rs at 25 °C; Bellcore Iss u e 2, Method 1, Case 3, Limited Part Stress Method Note C...
Page 18 - Physical Characteristics
NI 9217 Operating Instructions and Specifications 18 ni.com Physical Characteristics If yo u need to clean the mod u le, wipe it with a dry towel. Screw-terminal wiring ...................... 16 to 28 AWG copper cond u ctor wire with 7 mm (0.28 in.) of ins u lation stripped from the end Torq u e for...
Page 19 - Safety; Maximum Voltage
© National Instruments Corp. 19 NI 9217 Operating Instructions and Specifications Safety Maximum Voltage 1 Connect only voltages that are within the following limits. All terminals-to-COM.........................±30 V Isolation Voltages Channel-to-channel...........................None Channel-to-ea...
Page 20 - Safety Standards
NI 9217 Operating Instructions and Specifications 20 ni.com Caution Do not connect the NI 9217 to signals or u se for meas u rements within Meas u rement Categories III or IV. Safety Standards This prod u ct is designed to meet the req u irements of the following standards of safety for electrical e...
Page 21 - Hazardous Locations; Environmental
© National Instruments Corp. 21 NI 9217 Operating Instructions and Specifications Hazardous Locations U.S. (UL) .......................................... Class I, Division 2, Gro u ps A, B, C, D, T4; Class I, Zone 2,AEx nC IIC T4 Canada (C-UL) ................................. Class I, Division 2, ...
Page 22 - Shock and Vibration
NI 9217 Operating Instructions and Specifications 22 ni.com Operating h u midity (IEC 60068-2-56).............................. 10 to 90% RH, noncondensing Storage h u midity (IEC 60068-2-56).............................. 5 to 95% RH, noncondensing Maxim u m altit u de............................. 2...
Page 23 - Electromagnetic Compatibility; CE Compliance
© National Instruments Corp. 23 NI 9217 Operating Instructions and Specifications Electromagnetic Compatibility This prod u ct is designed to meet the req u irements of the following standards of EMC for electrical eq u ipment for meas u rement, control, and laboratory u se: • EN 61326 EMC req u ire...
Page 24 - Environmental Management; NI and the; Waste Electrical and Electronic Equipment (WEEE); EU Customers; must
NI 9217 Operating Instructions and Specifications 24 ni.com ni.com/certification , search by mod u le n u mber or prod u ct line, and click the appropriate link in the Certification col u mn. Environmental Management National Instr u ments is committed to designing and man u fact u ring prod u cts i...
Page 25 - Calibration; Yo; RoHS; National Instruments; about China RoHS compliance, go to
© National Instruments Corp. 25 NI 9217 Operating Instructions and Specifications Calibration Yo u can obtain the calibration certificate and information abo u t calibration services for the NI 9217 at ni.com/calibration . Calibration interval ........................... 1 year ⬉ᄤֵᙃѻક∵ᶧࠊㅵ⧚ࡲ⊩ ˄Ё Ro...
Page 26 - Where to Go for Support
NI 9217 Operating Instructions and Specifications 26 ni.com Where to Go for Support The National Instr u ments Web site is yo u r complete reso u rce for technical s u pport. At ni.com/ s upport yo u have access to everything from tro u bleshooting and application development self-help reso u rces t...