Honeywell 1533 - Manuals

Honeywell 1533 – User Manual, Manual, Installation Manual in PDF format online.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10

Summary

Page 2 - INDEX; Save this manual and NEVER keep it inside the chest.; DO NOT RETURN SAFE TO STORE

INDEX WELCOME ................................................................................................ PAGE 1 PRODUCT OVERVIEW .......................................................................... PAGE 1 PROPER USE OF YOUR CHEST .........................................................P...

Page 4 - Before using your new chest it should be opened and aired out for; Fire Protection; For optimum performance, Waterproof Fire Chests should be; HOW TO STORE CHEST

For your chest to perform as specified, it must always be stored flat with the lid on top and closed. Never store the chest on any of the sides or upside-down. 2 WRONG RIGHT Honeywell Waterproof Fire Chests are designed to protect paper documents and files from heat and moisture damage due to exposu...

Page 5 - TO CLOSE THE CHEST; UNLOCKING AND OPENING THE CHEST

3 1. Insert key into lock cylinder (Figure 1.1).2. Turn the key counterclockwise to the left ¼ turn (Figure 1.2).3. With key lock in the unlocked position, turn the knob to the right to the unlatched position (Figure 1.3).4. While holding the knob in the unlatched position, lift the lid to open (Fig...

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8

Summary

Page 2 - Installation Instructions; Mounting Requirements; INSTALLATION; immersion; Protection; H O; duct; Ensure no stratification

2 T-PI PRT Insertion Temperature Sensor Installation Instructions TG201420 Issue 2, 19-Feb-2020. T-PI Installation Instructions 2 Mounting Requirements Proceed to step 4 2 INSTALLATION (continued) For immersion applications Ensure no stratification (e.g. downstream of mixing dampers, heating coils, ...

Page 3 - Installation Instructions T-PI; Install as Immersion Sensor; Install Sensor into Pocket; spring compression fi tting; Install Pocket; or fi ll pocket with thermally conducting oil to avoid the build up

T-PI PRT Insertion Temperature Sensor Installation Instructions TG201420 Issue 2, 19-Feb-2020 3 Installation Instructions T-PI 3 Install as Immersion Sensor Proceed to step 5 2 INSTALLATION (continued) Install Sensor into Pocket (if using compatible pocket) Drill hole for boss Fix threaded boss R½” ...

Page 4 - Install as Duct Sensor; compression fi tting

4 T-PI PRT Insertion Temperature Sensor Installation Instructions TG201420 Issue 2, 19-Feb-2020 . T-PI Installation Instructions 4 Install as Duct Sensor 2 INSTALLATION (continued) Either: Direct mount sensor on duct Drill hole in duct Ø 7 mm (0.28”) Drill 2 pilot holes 42.5 mm (1.67”) 85 mm (3.35”)...

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12

Summary

Page 2 - Installation Instructions; wire method; f u s e; : This apparatus must be earthed; holes

2 IQ246 Controller Installation Instructions TG200101 Issue 1/E 15/01/07 IQ246 Installation Instructions 5 Connecting Network R+ R- T+ T- 24 V d c 0 V AUX 24 V d c 0 V POW E R R+R-T+T- R+ R- T+ T- R R T T R+R-T+T- R+ R- T+ T- R R T T R R T T 4 wire method Connect to T &R of previousdevice, polar...

Page 3 - Analog Inputs; Use Trend Cables

3 IQ246 Controller Installation Instructions TG200101 Issue 1/E 15/01/07 Installation Instructions IQ246 6 Wire I/O Terminals Analog Inputs J3 37 Way 'D type' Male Analog Outputs J4 15 Way 'D type' Male Digital Inputs J2 37 Way 'D type' Female Analog Outputs J5 15 Way 'D type' Female 37 Way 'D type'...

Page 4 - Connect Auxiliary Output Supply; Relay; Connect Inputs; SIG; Connect Outputs; T h e w i r e s m a y b e c o n n e c t e d t o; I N

4 IQ246 Controller Installation Instructions TG200101 Issue 1/E 15/01/07 IQ246 Installation Instructions 9 Connect Auxiliary Output Supply R+ R- T+ T- 24 V d c 0 V AUX 24 V d c 0 V POW E R 24 Vdc Auxiliary Output Supply 0 V 24 V 0 V 24 Vdc I max = 500 mA For relays, NDPe . g . SRMV = 2SRM = 2RM = 3R...

Honeywell Manuals