Honeywell 24DX47 - User Manual

Honeywell 24DX47

Honeywell 24DX47 – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
Page: / 41

Table of Contents:

  • Page 3 – ABOUT THIS GUIDE; Waste Electrical and; EMF Statement
  • Page 4 – Professional installation Warning; WARNING; INTRODUCTION
  • Page 5 – DIMENSIONS
  • Page 6 – SPECIFICATIONS
  • Page 8 – SYSTEM ARCHITECTURE; Fig. 3 System Architecture
  • Page 9 – INSTALLATION; Important Safety Information and; CAUTION; Before Installation
  • Page 10 – Restricting Access to Network
  • Page 15 – GETTING STARTED; Home Screen - User Interface; Table 15 D1-529 Thermostat User Interface
  • Page 16 – D-X47 LED and Terminal
  • Page 17 – INITIAL CONFIGURATION; Set the Room ID
  • Page 18 – Room Copy
  • Page 19 – Setup Fan Speed
  • Page 20 – Deploy the Property Key
  • Page 21 – ADVANCED CONFIGURATION
  • Page 24 – Tune Energy Savings
  • Page 28 – Limited Energy Management Mode
  • Page 30 – Service Parameter SEr
  • Page 31 – Run Menu Parameters rUn
  • Page 32 – EEr – Read and Display NVRAM of D-
  • Page 37 – TROUBLESHOOTING; during initial installation or while
  • Page 38 – Up or Down; Changes done via RBM, does not
  • Page 40 – RESETTING AND REBOOTING
Loading the manual

® U.S. Registered Trademark

Copyright © 2024 Honeywell Inc. • All Rights Reserved

31-00722-01

INSTALLATION INSTRUCTIONS

LEGENDS

GREEN - NEED INPUTS

BLUE - NEED CONFIRMATION

RED - PLACEHOLDER

Draft 1.7 May 31, 2024

INNCOM DIRECT D1-529

THERMOSTAT & D-X47 HVAC

CONTROLLER

About this Guide .................................................................. 3

General safety information ............................................... 3

Certification and REGULATION ....................................... 3

Waste Electrical and Electronic Equipment (WEEE) . 3

FCC Part 15 compliant ........................................................... 3

Canadian Regulatory Statement........................................ 3

Professional installation Warning ..................................... 4

Power Supply Guidelines and Requirements ................ 4

Introduction .......................................................................... 4

D1-529 Thermostat................................................................. 4

D-X47 Relay ................................................................................ 4

Features.................................................................................. 4

D-X47 Relay ................................................................................ 4

Dimensions ............................................................................ 5

D1-529 Thermostat................................................................. 5

D-X47 Relay ................................................................................ 5

Specifications

(D1-529 Thermostat).......................................................... 6

General ......................................................................................... 6

Electrical ...................................................................................... 6

Sensors ......................................................................................... 6

Environmental Specifications ............................................. 6

Weight and Dimensions ........................................................ 6

Display .......................................................................................... 6

Communications ...................................................................... 6

Standards and Approvals ...................................................... 7

Specifications

(D-X47 Relay) ........................................................................ 7

General ......................................................................................... 7

Electrical ...................................................................................... 7

Environmental Specifications ............................................. 7

Weight and Dimensions ........................................................ 7

Standards and Approvals ...................................................... 7

System Architecture............................................................ 8

Installation ............................................................................ 9

Important Safety Information and Installation

Precautions ................................................................................. 9

Before Installation ................................................................... 9

Restricting Access to Network............................................. 10

Location (D1-529 Thermostat) ................................... 10

Location (D-X47 Relay) .......................................................... 10

Mounting (D1-529 Thermostat) ........................................ 11

Mounting (D-X47 Relay)........................................................ 12

Wiring Connections (D-X47 Relay) ................................... 13

Getting Started..................................................................... 15

Home Screen - User Interface

(D1-529) ...................................................................................... 15

D1-529 LCD ............................................................................... 15

D-X47 LED and Terminal ...................................................... 16

D1-529 Configuration Parameters................................... 16

Initial Configuration ........................................................... 17

Set the Room ID ........................................................................ 17

Connect the D1-529 with D-X47 ....................................... 18

Room Copy.................................................................................. 18

Setup HVAC Type...................................................................... 19

Setup Fan Speed ...................................................................... 19

Deploy the Property Key ........................................................ 20

Advanced Configuration .................................................... 21

Set the Room ID ........................................................................ 21

Room Copy.................................................................................. 22

Setup HVAC Type...................................................................... 22

Setup Fan Speed ...................................................................... 23

Tune Energy Savings .............................................................. 24

tt (Selectable target temperature range) ................. 24

dLt (UnOccupied Delta).................................................. 24

Uot (Unoccupied Time) ................................................... 25

UrS (Unrented Setback).................................................. 25

Urt (Unrented Time after Unoccupied)..................... 26

Pan ID (PAn) ............................................................................... 26

RF Channel (rF)......................................................................... 27

Ping Device (Pn6)..................................................................... 27

Contractor Mode (Ctr) ............................................................ 28

Limited Energy Management Mode LEn ....................... 28

PIR Motion Sensor Test (Plr)................................................ 29

Door Test (dor) ........................................................................... 29

Window Test (Uln) .................................................................... 29

Measured Room Humidity (rH) .......................................... 30

Service Parameter SEr ........................................................... 30

Local D1-529 Settings (LoC) .............................................. 31

Run Menu Parameters rUn .................................................. 31

EEr – Read and Display NVRAM of D-X47 ..................... 32

6r.A - CBL32 Registry Group 9 Thermo/HVAC Editor 33

Address Parameter (Adr) ....................................................... 33

IO Map Parameter (Io)............................................................ 34

Replacing D1-529 And D-X47 .......................................... 35

Replacing the D1-529............................................................ 35

Replacing the D-X47............................................................... 36

Troubleshooting ................................................................... 37

Cannot bind the D1-529 and D-X47 during initial

installation or while replacing a D1-529/D-X47......... 37

D1-529 thermostat is not controlling the D-X47

locally in a room........................................................................ 37

Changes done via RBM, does not appear in the

room D1-529 Thermostat..................................................... 38

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Honeywell 24DX47

Summary

Page 3 - ABOUT THIS GUIDE; Waste Electrical and; EMF Statement

INNCOM DIRECT D1-529 THERMOSTAT & D-X47 HVAC CONTROLLER INSTALLATION GUIDE 3 31-00722-01 LEGENDS GREEN - NEED INPUTS BLUE - NEED CONFIRMATION RED - PLACEHOLDER Draft 1.7 May 31, 2024 ABOUT THIS GUIDE This Guide provides information about the Installation details of the INNCOM direct D1-529 Therm...

Page 4 - Professional installation Warning; WARNING; INTRODUCTION

INNCOM DIRECT D1-529 THERMOSTAT & D-X47 HVAC CONTROLLER INSTALLATION GUIDE 31-00722-01 4 LEGENDS GREEN - NEED INPUTS BLUE - NEED CONFIRMATION RED - PLACEHOLDER Draft 1.7 May 31, 2024 Professional installation Warning • This device must be professionally installed, this should be noted on grantee...

Page 5 - DIMENSIONS

INNCOM DIRECT D1-529 THERMOSTAT & D-X47 HVAC CONTROLLER INSTALLATION GUIDE 5 31-00722-01 LEGENDS GREEN - NEED INPUTS BLUE - NEED CONFIRMATION RED - PLACEHOLDER Draft 1.7 May 31, 2024 DIMENSIONS D1-529 Thermostat Fig. 1 D1-529 Thermostat Dimensions D-X47 Relay Fig. 2 D-X47 Relay Dimensions 4.7 in...

Other Honeywell Models