- Page 3 – ABOUT THIS GUIDE; Waste Electrical and; EMF Statement
- Page 4 – Professional installation Warning; WARNING; INTRODUCTION
- Page 5 – DIMENSIONS
- Page 6 – SPECIFICATIONS
- Page 8 – SYSTEM ARCHITECTURE; Fig. 3 System Architecture
- Page 9 – INSTALLATION; Important Safety Information and; CAUTION; Before Installation
- Page 10 – Restricting Access to Network
- Page 15 – GETTING STARTED; Home Screen - User Interface; Table 15 D1-529 Thermostat User Interface
- Page 16 – D-X47 LED and Terminal
- Page 17 – INITIAL CONFIGURATION; Set the Room ID
- Page 18 – Room Copy
- Page 19 – Setup Fan Speed
- Page 20 – Deploy the Property Key
- Page 21 – ADVANCED CONFIGURATION
- Page 24 – Tune Energy Savings
- Page 28 – Limited Energy Management Mode
- Page 30 – Service Parameter SEr
- Page 31 – Run Menu Parameters rUn
- Page 32 – EEr – Read and Display NVRAM of D-
- Page 37 – TROUBLESHOOTING; during initial installation or while
- Page 38 – Up or Down; Changes done via RBM, does not
- Page 40 – RESETTING AND REBOOTING
® U.S. Registered Trademark
Copyright © 2024 Honeywell Inc. • All Rights Reserved
31-00722-01
INSTALLATION INSTRUCTIONS
LEGENDS
GREEN - NEED INPUTS
BLUE - NEED CONFIRMATION
RED - PLACEHOLDER
Draft 1.7 May 31, 2024
INNCOM DIRECT D1-529
THERMOSTAT & D-X47 HVAC
CONTROLLER
About this Guide .................................................................. 3
General safety information ............................................... 3
Certification and REGULATION ....................................... 3
Waste Electrical and Electronic Equipment (WEEE) . 3
FCC Part 15 compliant ........................................................... 3
Canadian Regulatory Statement........................................ 3
Professional installation Warning ..................................... 4
Power Supply Guidelines and Requirements ................ 4
Introduction .......................................................................... 4
D1-529 Thermostat................................................................. 4
D-X47 Relay ................................................................................ 4
Features.................................................................................. 4
D-X47 Relay ................................................................................ 4
Dimensions ............................................................................ 5
D1-529 Thermostat................................................................. 5
D-X47 Relay ................................................................................ 5
(D1-529 Thermostat).......................................................... 6
General ......................................................................................... 6
Electrical ...................................................................................... 6
Sensors ......................................................................................... 6
Environmental Specifications ............................................. 6
Weight and Dimensions ........................................................ 6
Display .......................................................................................... 6
Communications ...................................................................... 6
Standards and Approvals ...................................................... 7
(D-X47 Relay) ........................................................................ 7
General ......................................................................................... 7
Electrical ...................................................................................... 7
Environmental Specifications ............................................. 7
Weight and Dimensions ........................................................ 7
Standards and Approvals ...................................................... 7
System Architecture............................................................ 8
Installation ............................................................................ 9
Important Safety Information and Installation
Precautions ................................................................................. 9
Before Installation ................................................................... 9
Restricting Access to Network............................................. 10
Location (D1-529 Thermostat) ................................... 10
Location (D-X47 Relay) .......................................................... 10
Mounting (D1-529 Thermostat) ........................................ 11
Mounting (D-X47 Relay)........................................................ 12
Wiring Connections (D-X47 Relay) ................................... 13
Getting Started..................................................................... 15
(D1-529) ...................................................................................... 15
D1-529 LCD ............................................................................... 15
D-X47 LED and Terminal ...................................................... 16
D1-529 Configuration Parameters................................... 16
Initial Configuration ........................................................... 17
Set the Room ID ........................................................................ 17
Connect the D1-529 with D-X47 ....................................... 18
Room Copy.................................................................................. 18
Setup HVAC Type...................................................................... 19
Setup Fan Speed ...................................................................... 19
Deploy the Property Key ........................................................ 20
Advanced Configuration .................................................... 21
Set the Room ID ........................................................................ 21
Room Copy.................................................................................. 22
Setup HVAC Type...................................................................... 22
Setup Fan Speed ...................................................................... 23
Tune Energy Savings .............................................................. 24
tt (Selectable target temperature range) ................. 24
dLt (UnOccupied Delta).................................................. 24
Uot (Unoccupied Time) ................................................... 25
UrS (Unrented Setback).................................................. 25
Urt (Unrented Time after Unoccupied)..................... 26
Pan ID (PAn) ............................................................................... 26
RF Channel (rF)......................................................................... 27
Ping Device (Pn6)..................................................................... 27
Contractor Mode (Ctr) ............................................................ 28
Limited Energy Management Mode LEn ....................... 28
PIR Motion Sensor Test (Plr)................................................ 29
Door Test (dor) ........................................................................... 29
Window Test (Uln) .................................................................... 29
Measured Room Humidity (rH) .......................................... 30
Service Parameter SEr ........................................................... 30
Local D1-529 Settings (LoC) .............................................. 31
Run Menu Parameters rUn .................................................. 31
EEr – Read and Display NVRAM of D-X47 ..................... 32
6r.A - CBL32 Registry Group 9 Thermo/HVAC Editor 33
Address Parameter (Adr) ....................................................... 33
IO Map Parameter (Io)............................................................ 34
Replacing D1-529 And D-X47 .......................................... 35
Replacing the D1-529............................................................ 35
Replacing the D-X47............................................................... 36
Troubleshooting ................................................................... 37
Cannot bind the D1-529 and D-X47 during initial
installation or while replacing a D1-529/D-X47......... 37
D1-529 thermostat is not controlling the D-X47
locally in a room........................................................................ 37
Changes done via RBM, does not appear in the
room D1-529 Thermostat..................................................... 38
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Honeywell 24DX47
Summary
INNCOM DIRECT D1-529 THERMOSTAT & D-X47 HVAC CONTROLLER INSTALLATION GUIDE 3 31-00722-01 LEGENDS GREEN - NEED INPUTS BLUE - NEED CONFIRMATION RED - PLACEHOLDER Draft 1.7 May 31, 2024 ABOUT THIS GUIDE This Guide provides information about the Installation details of the INNCOM direct D1-529 Therm...
INNCOM DIRECT D1-529 THERMOSTAT & D-X47 HVAC CONTROLLER INSTALLATION GUIDE 31-00722-01 4 LEGENDS GREEN - NEED INPUTS BLUE - NEED CONFIRMATION RED - PLACEHOLDER Draft 1.7 May 31, 2024 Professional installation Warning • This device must be professionally installed, this should be noted on grantee...
INNCOM DIRECT D1-529 THERMOSTAT & D-X47 HVAC CONTROLLER INSTALLATION GUIDE 5 31-00722-01 LEGENDS GREEN - NEED INPUTS BLUE - NEED CONFIRMATION RED - PLACEHOLDER Draft 1.7 May 31, 2024 DIMENSIONS D1-529 Thermostat Fig. 1 D1-529 Thermostat Dimensions D-X47 Relay Fig. 2 D-X47 Relay Dimensions 4.7 in...