- Page 2 – Installation Instructions; wire method; f u s e; : This apparatus must be earthed; holes
- Page 3 – Analog Inputs; Use Trend Cables
- Page 4 – Connect Auxiliary Output Supply; Relay; Connect Inputs; SIG; Connect Outputs; T h e w i r e s m a y b e c o n n e c t e d t o; I N
- Page 5 – Set Network Address
- Page 6 – Replace Board; tighten 4 screws; Plug in Main Controller Unit; screw in thumb knobs; Set Analogue Input Channel Links; board; Plug in Ribbon Cable
- Page 7 – Check Controller; Configure; Check Network
- Page 8 – Backup; OR; Close Panel; Test Analogue Inputs; Test Outputs; V B
- Page 9 – SET; Opening the panel; WARNING; The connecting
- Page 10 – Replace Battery; REPLACING THE BATTERY; Warning
- Page 12 – Trend Control Systems Limited; Download Strategy; Set Network Baud Rate; Baud Rate; DISPOSAL
1
IQ246 Controller Installation Instructions TG200101 Issue 1/E 15/01/07
Important: Retain these instructions
Installation Instructions
IQ246
Controller
CONTENTS
1
Unpacking
1
2
Storing
1
3
Installation Instructions
1
TX
RX
OK
I Q 2 4 6
1
2
3
4
16
32
64
19K2
9K2
1K2
R+
R-
T+
T-
24
V
d
c
0 V
AUX
24
V
d
c
0 V
PO
WER
Dimensions
Requirements
TX
RX
OK
I Q 2 4 6
TX
RX
OK
I Q 2 4 6
a
b
c
H O
2
0 °C
(32 °F)
+45 °C
(113 °F)
0 %RH
90 %RH
d
1
2
It is recommended that the installation should
comply with the HSE Memorandum of Guidance
on Electricity at Work Regulations 1989.
For USA install equipment in accordance with
National Electric Code.
H O
2
+50 °C
(122 °F)
0
-10 °C
(14 °F)
90 %RH
TX
RX
OK
I Q 2 4 6
Installation
Instructions
TG200101
TX
RX
OK
I Q 2 4 6
e
TX
RX
OK
I Q 2 4 6
R+
R-
T+
T-
24 Vdc
0 V
AU
X
24 Vdc
0 V
POW
E
R
3.1 Installation - Mounting
1
3.2 Installation - Configuration
5
4
Replacing the Battery
9
5
Disposal
12
1 UNPACKING
2 STORING
3 INSTALLATION INSTRUCTIONS
3.1 Installation - Mounting
40 mm
(1.57”)
155 mm (6.1”)
20 mm
(0.79”)
300 mm (11.81”)
210 mm (8.27”)
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Honeywell 1533
Summary
2 IQ246 Controller Installation Instructions TG200101 Issue 1/E 15/01/07 IQ246 Installation Instructions 5 Connecting Network R+ R- T+ T- 24 V d c 0 V AUX 24 V d c 0 V POW E R R+R-T+T- R+ R- T+ T- R R T T R+R-T+T- R+ R- T+ T- R R T T R R T T 4 wire method Connect to T &R of previousdevice, polar...
3 IQ246 Controller Installation Instructions TG200101 Issue 1/E 15/01/07 Installation Instructions IQ246 6 Wire I/O Terminals Analog Inputs J3 37 Way 'D type' Male Analog Outputs J4 15 Way 'D type' Male Digital Inputs J2 37 Way 'D type' Female Analog Outputs J5 15 Way 'D type' Female 37 Way 'D type'...
4 IQ246 Controller Installation Instructions TG200101 Issue 1/E 15/01/07 IQ246 Installation Instructions 9 Connect Auxiliary Output Supply R+ R- T+ T- 24 V d c 0 V AUX 24 V d c 0 V POW E R 24 Vdc Auxiliary Output Supply 0 V 24 V 0 V 24 Vdc I max = 500 mA For relays, NDPe . g . SRMV = 2SRM = 2RM = 3R...