Page 2 - Technical specifications; Oscilloscope mode
2 Fluke Corporation ScopeMeter 215C, 225C and 190C Series, 120 Series Fluke 225C Fluke 215C Fluke 192C Fluke 199C Fluke 196C Bandwidth 200 MHz 100 MHz 60 MHz Rise time 1.7 ns 3.5 ns 5.8 ns Bandwidth limiter: User selectable: 10 kHz, 20 MHz or off Number of inputs: Two plus external trigger. All inpu...
Page 4 - Accessories
Memory save and recall Scope memories: 15 memory locations that each can contain two waveforms plus corresponding setup. With each storage action, a user specified name (20 ASCII characters long) can be assigned to the stored data, for easier reference. Recorder memories: 2 memory locations that eac...
Page 5 - Vertical deflection; Horizontal; Number of digitizers:; Display and acquisition; Technical specifications 120 Series
Cursor measurements (125, 124) Sources: Input A, Input B Modes: Single or dual vertical cursor, dual horizontal cursor, risetime or falltime Measurements: Single vertical line: Average, min value, max value, time from start of recording in roll mode Dual vertical lines: ∆ V at markers, time between ...
Page 6 - Dual input meter
Recorder mode Trendplot recording Dual input electronic paperless chart recorder. Plots and displays the actual, minimum, maximum and average of any measurement. Source and display: Input A, input A and B Range: 15 s/div to 2 days per division (automatic) Recorded timespan: Up to 16 days with a reso...
Page 7 - FlukeView; Maximum input voltage:
System requirements • Pentium 90 or better • CD-ROM drive • Microsoft ® Windows ® (2000 and beyond) • One free RS232 port or USB port • PM9080 optically isolated RS232 adapter/cable, or: • OC4USB optically isolated USB interface adapter/ cable, available separately or included in SCC120/ SCC190 kit ...
Page 8 - Cable kits
Accessories Standard accessories Fluke 225C, 215C, 199C, 196C, 192C Fluke 125, Fluke 124, Fluke 123 Rechargeable battery pack (installed) BP190 BP120MH Line voltage adapter/ battery charger BP190 PM8907 Voltage probes and accessories 10:1 voltage probe (VPS210) including hook clip, ground lead with ...
Page 9 - International safety standards; Ordering information
Measurement voltage category Summary description CAT IV Three phase at utility connection, any outdoor conductors (under 1,000 V) • Outside and service entrance • Service drop from pole to building • Run between meter and panel • Overhead line to detached building • Underground line to well pump CAT...
Page 10 - Selection guide; Keeping your world
Selection guide Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A. Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (80...