Page 2 - TABLE OF CONTENTS; SECTION
24632-0-0508 Page 2 TABLE OF CONTENTS SECTION PAGE Included in the Box .................................................................................................. 3 Hardware Packets .................................................................................................... 4 Tools Ne...
Page 3 - INCLUDED IN THE BOX
24632-0-0508 Page 3 INCLUDED IN THE BOX DIRECT VENT HEATER (INSIDE WALL MOUNTING PLATE ATTACHED ON BACK) INLET & OUTLET TUBES INSTALLATION TEMPLATE (TEMPLATE FOR HWDV080 ON REVERSE SIDE) OUTSIDE WALL MOUNTING PLATE & VENT CAP VENT KIT HARDWARE PACKET VENT SHIELD HEATER HARDWARE PACKET
Page 6 - UNIT DIMENSIONS; MAKE SURE THAT APPLIANCE IS SUITABLE FOR THE GAS SUPPLY AVAILABLE:; NATURAL GAS; OR
24632-0-0508 Page 6 UNIT DIMENSIONS MAKE SURE THAT APPLIANCE IS SUITABLE FOR THE GAS SUPPLY AVAILABLE: NATURAL GAS OR PROPANE/LP.
Page 7 - IMPORTANT SAFETY INFORMATION; Follow State and Local codes for installation.
24632-0-0508 Page 7 IMPORTANT SAFETY INFORMATION Children and adults should be alerted to the haz- ards of high surface temperatures and should stay away to avoid burns or clothing ignition.Any safety screen or guard removed for servicing must be replaced prior to operating the heater.Do not use thi...
Page 8 - SAFETY INFORMATION FOR USERS OF LP-GAS
24632-0-0508 Page 8 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detec...
Page 9 - INTRODUCTION
24632-0-0508 Page 9 Qualified Installing Agency Installation and replacement of gas piping, gas utilization equip- ment or accessories and repair and servicing of equipment shall be performed by a qualified agency. The term “qualified agency” means any individual, firm, corporation or company which eith...
Page 10 - REQUIREMENTS FOR MASSACHUSETTS
24632-0-0508 Page 10 REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust v...
Page 11 - TERMINATION CLEARANCES
24632-0-0508 Page 11 TERMINATION CLEARANCES Description US Installations 1 A Clearance above grade, veranda, porch, deck, or balcony 12 inches (305 mm) B Clearance to window or door that may be open 6 inches (152 mm) for appliance ≤ 10,000 Btuh (3 kW), 9 inches (229 mm) for appliances > 10,000 Bt...
Page 12 - GAS SUPPLY
24632-0-0508 Page 12 Installing a New Main Gas Cock Each appliance should have its own manual gas cock.A manual main gas cock should be located in the vicinity of the unit. Where none exists, or where its size or location is not adequate, contact your local authorized installer for installation or r...
Page 13 - CLEARANCES
24632-0-0508 Page 13 WARNING: The nearest point of the vent cap should be a minimum horizontal distance of six (6) (1.83m) feet from any pressure regulator. In case of regulator malfunction, the six (6) foot (1.83m) distance will reduce the chance of gas entering the vent cap. CLEARANCES GAS SUPPLY ...
Page 14 - INSTALLATION INSTRUCTIONS OVERVIEW
24632-0-0508 Page 14 INSTALLATION INSTRUCTIONS OVERVIEW Figure 4 Figure 5 Figure 6 Location - All Models Select a location near the center of the space to be heated. Overflow heat will circulate through doorways into adjacent rooms. The furnace is to be located on an outside wall. Locate wall studs s...
Page 15 - INSTALLATION AND ASSEMBLY; accessibility for purposes of servicing and proper operation.
24632-0-0508 Page 15 1 Note: All references must be considered as if the observer is standing in front of the wall and/or appliance. HEATER TO BACK CASING MOUNTING SCREWS WALL MOUNTING TAB WALL MOUNTING SCREWS WALL MOUNTING PLATE Mark the venting system hole location (as indicated on page 18) and th...
Page 16 - INSTALLATION OF HOUSEWARMER PRODUCT
24632-0-0508 Page 16 2 SILICON-BASED SEALANT MOUNTING PLATE CAP FLUE OUTLET TUBE AIR INLET TUBE Failure to position these parts in accordance with diagram or failure to use only parts specifically approved with these appliances may result in property damage or personal injury. 3 INSTALLATION OF HOUSE...
Page 17 - INTERIOR PREPARATION AND INSTALLATION OF THE BACK OF THE UNIT
24632-0-0508 Page 17 2 INTERIOR PREPARATION AND INSTALLATION OF THE BACK OF THE UNIT Locate the wall mounting plate template included in your kit and remove the perforated sections. Use painters tape to secure the wall mounting plate template onto the interior wall where the heater will be located. ...
Page 20 - INTERIOR INSTALLATION OF THE FRONT OF THE UNIT
24632-0-0508 Page 20 INTERIOR INSTALLATION OF THE FRONT OF THE UNIT 1 2 3 Line up the two (2) tabs on the top of the wall mounting plate with the holes in the back of the unit. Slide the back of the unit onto the tabs of the wall mounting plate. After the back of the unit is attached to the wall, br...
Page 21 - CUTTING THE VENT TUBES
24632-0-0508 Page 21 CUTTING THE VENT TUBES 1 2 4 1/2” to 12” THICK WALL This unit is to be installed on wall from 4 1/2" to 12" (114.3 mm to 304.8 mm) thick. FLUE OUTLET TUBE AIR INLET TUBE MOUNTING PLATE SCREWS (3X) LONG SCREWS (4X) CAP NOTE: Flue outlet tube and air inlet tube should be m...
Page 23 - EXTERIOR INSTALLATION OF THE VENTING
24632-0-0508 Page 23 3 1 2 EXTERIOR INSTALLATION OF THE VENTING Attach 5" (127 mm) diameter air inlet tube onto the collar of air drop assembly. Attach caulked, outside wall mounting plate into the 5" (127 mm) diameter air inlet tube. Flue outlet tube must be tightly sealed against the heate...
Page 26 - REASSEMBLY AND RESEALING VENT-AIR INTAKE SYSTEM
24632-0-0508 Page 26 1 2 3 REASSEMBLY AND RESEALING VENT-AIR INTAKE SYSTEM When vent-air intake system is removed for servicing the furnace, the following steps will assure proper reassembly and resealing of the vent-air intake assembly. Remove old furnace cement from flue outlet collar on combustion...
Page 29 - INSTALLATION OF OPTIONAL BLOWER KIT HW125SCB
24632-0-0508 Page 29 INSTALLATION OF OPTIONAL BLOWER KIT HW125SCB 1 Remove front panel of heater by opening, then lifting one side out then the other. 2 Disconnect the power cord from the blower assembly. 3 Remove ground screw from blower mounting bracket.
Page 33 - BEFORE OPERATING APPLIANCE; CHECK THE FOLLOWING BEFORE OPERATING APPLIANCE; ATTENTION INSTALLER: INSTRUCT YOUR CUSTOMER ABOUT THE CORRECT
24632-0-0508 Page 33 WARNING Improper installation, adjustments, alterations, service or maintenance can cause property damage, personal injury or loss of life. Installation and service must be conducted by a Qualified Service Person. Under no circumstances should these heaters be modified.In case of ...
Page 37 - OPERATING INSTRUCTIONS; FOR YOUR SAFETY READ BEFORE LIGHTING
24632-0-0508 Page 37 OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury, or loss of life. Installation and service must be performed by a qualified installer, service age...
Page 40 - MAINTENANCE INSTRUCTIONS; CLEANING BURNER AND PILOT
24632-0-0508 Page 40 MAINTENANCE INSTRUCTIONS WARNING: • Prior to any maintenance operation, it will be necessary to close the gas supply. • Only qualified personnel are allowed to operate these appliances without the front cabinet installed. OPERATION FREQUENCY FAULTS TO BE PREVENTED REMARKS Externa...
Page 42 - PARTS LIST
24632-0-0508 Page 42 USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. PARTS LIST INDEX NO. PART NO. DESCRIPTION HWDV080 HWDV181 1 24622 24623 WALL M...
Page 44 - PARTS VIEW
24632-0-0508 Page 44 PARTS VIEW 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41
Page 45 - SERVICE NOTES
Page 48 - EMPIRE
24632-0-0508 Page 48 HOUSEWARMER is a registered trademark of Empire Comfort Systems Inc. www.housewarmerproducts.com EMPIRE EMPIRE Comfort Systems Manufactured for: Empire Comfort Systems Inc. 918 Freeburg Ave. Belleville, IL 62220 PH:877-459-1583 FAX: 877-459-0514