Page 2 - Safety and General Information; SAVE THESE INSTRUCTIONS - This section contains important; Inventory
Back-UPS BC650-RSX761 2 Safety and General Information SAVE THESE INSTRUCTIONS - This section contains important instructions that should be followed during installation and maintenance of the UPS and batteries. • This UPS is intended for indoor use only.• Connect the Back-UPS power cable directly t...
Page 3 - Specifications
Back-UPS BC650-RSX761 3 Turn On the Back-UPS Press the Power ON button located on the front panel of the Back-UPS. The Power On/Replace Battery LED will illuminate and a single short beep will be audible to indicate that the Back-UPS is providing protection for connected equipment.The Back-UPS batte...
Page 4 - Connect the Equipment; Mi
Back-UPS BC650-RSX761 4 Connect the Equipment O N /O FF button Use to turn on/off the UPS. Battery connector Connect the internal battery before use. Circuit breaker Use to reset the system after an overload condition has occurred causing the circuit breaker to trip. Battery and surge protec...
Page 5 - Transfer Voltage and Sensitivity Settings; Voltage regulation; Voltage sensitivity adjustment
Back-UPS BC650-RSX761 5 Transfer Voltage and Sensitivity Settings Voltage regulation The Back-UPS will switch to battery power if the AC input voltage level becomes too low or too high, or if the AC power is experiencing voltage fluctuations. No-load shutdown The UPS will shut down to conserve energ...
Page 6 - Status Indicators
Back-UPS BC650-RSX761 6 Status Indicators LED Flashes Audible Indicato r Voltage Sensitivity Setting Input Voltage Range No-load Shutdown Recommended Use Once per second None Low 160-278 Disabled The Back-UPS will switch to battery power less often. Use this setting for equipment that is not sensiti...
Page 8 - Battery Replacement; CAUTION; RISK OF HYDROGEN SULPHIDE GAS AND EXCESSIVE SMOKE; Failure to follow these instructions could result in minor or
Back-UPS BC650-RSX761 8 Battery Replacement • The battery in the Back-UPS is not user-replaceable. Contact APC by Schneider Electric Sales and SEIT Technical Support for a list of authorized service centers near you. • Servicing of user replaceable batteries should be performed or supervised by pers...
Page 9 - Troubleshooting
Back-UPS BC650-RSX761 9 • CAUTION: A battery can present a risk of electrical shock and high short- circuit current. The following precautions should be observed when working on batteries: – Disconnect the charging source prior to connecting or disconnecting battery terminals. – Do not wear any meta...
Page 10 - Warranty
Back-UPS BC650-RSX761 10 Warranty The standard warranty is two (2) years from the date of purchase. Schneider Electric IT (SEIT) standard procedure is to replace the original unit with a factory reconditioned unit. Customers who must have the original unit back due to the assignment of asset tags an...
Page 11 - Service
Back-UPS BC650-RSX761 11 Service If the unit requires service, do not return it to the dealer. Follow these steps: 1. Review the Troubleshooting section of the manual to eliminate common problems. 2. If the problem persists, contact SEIT Customer Support through the Web site, www.apc.com. a. Note th...