Page 3 - Table of Contents; Safety
Dinion2X IP Camera Table of Contents | en 3 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 Table of Contents 1 Safety 8 1.1 Safety precautions 8 1.2 Important safety instructions 9 1.3 Connection in applications 10 1.4 FCC & ICES compliance 11 1.5 UL certi...
Page 4 - Planning
4 en | Table of Contents Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 4 Planning 24 4.1 Unpacking 24 4.2 System requirements 25 4.3 Install players 26 5 Installation 27 5.1 Network (and power) connector 27 5.2 Power connector 28 5.3 Alarm ...
Page 5 - Basic Mode
Dinion2X IP Camera Table of Contents | en 5 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 7.3 Protected network 44 7.4 Connecting to a hardware decoder 45 7.4.1 Alarm connection 45 7.5 Connection established 46 7.5.1 LIVEPAGE 46 7.5.2 RECORDINGS 46 7.5.3 SETT...
Page 7 - Operation via the browser
Dinion2X IP Camera Table of Contents | en 7 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 9.11.3 System Overview 113 10 Operation via the browser 114 10.1 Livepage 114 10.1.1 Processor load 114 10.1.2 Image selection 115 10.1.3 View Control 115 10.1.4 Digital...
Page 8 - Safety precautions
8 en | Safety Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 1 Safety 1.1 Safety precautions DANGER! High risk: This symbol indicates an imminently hazardous situation such as "Dangerous Voltage" inside the product. If not avoided, t...
Page 9 - Important safety instructions
Dinion2X IP Camera Safety | en 9 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 1.2 Important safety instructions Read, follow, and retain for future reference all of the following safety instructions. Follow all warnings on the unit and in the operating instr...
Page 10 - Connection in applications
10 en | Safety Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 1.3 Connection in applications Power lines: An outdoor system should not be located in the vicinity of overhead power lines, electrical lights, or power circuits, or where it may ...
Page 11 - FCC & ICES compliance; FCC & ICES Information; residential
Dinion2X IP Camera Safety | en 11 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 1.4 FCC & ICES compliance FCC & ICES Information (U.S.A. and Canadian Models Only) This equipment has been tested and found to comply with the limits for a Class B digital...
Page 12 - Informations FCC et ICES; installation résidentielle
12 en | Safety Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems Informations FCC et ICES (modèles utilisés aux États-Unis et au Canada uniquement) Suite à différents tests, cet appareil s'est révélé conforme aux exigences imposées aux appareil...
Page 13 - UL certification; Disclaimer
Dinion2X IP Camera Safety | en 13 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 1.5 UL certification Disclaimer Underwriter Laboratories Inc. ("UL") has not tested the performance or reliability of the security or signaling aspects of this product. UL...
Page 14 - Bosch notices; Video loss
14 en | Safety Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 1.6 Bosch notices Video loss Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing vi...
Page 15 - Copyrights
Dinion2X IP Camera Safety | en 15 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 1.7 Copyrights The firmware 4.1 uses the fonts "Adobe-Helvetica-Bold-R- Normal--24-240-75-75-P-138-ISO10646-1" and "Adobe- Helvetica-Bold-R-Normal--12-120-75-75-P-70-I...
Page 16 - Introduction; Features
16 en | Introduction Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 2 Introduction 2.1 Features The Dinion2x IP Day/Night camera is a high-performance, smart surveillance color camera. It incorporates 20-bit digital signal processing and a w...
Page 18 - System Information; Overview of functions; Progressive scan
18 en | System Information Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 3 System Information 3.1 Overview of functions The camera incorporates a network video server. Its primary function is to encode video and control data for transmissio...
Page 19 - ONVIF (Open Network Video Interface Forum)
Dinion2X IP Camera System Information | en 19 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 3.1.4 Tri-streaming Tri-streaming allows the data stream to be encoded simultaneously according to three different, individually customized profiles. This creates two ...
Page 22 - Operation with external systems; Bosch Video Management System
22 en | System Information Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 3.2 Operation with external systems The camera can be used with a variety of Bosch software and hardware systems: – Bosch Video Management System – VIDOS video managem...
Page 24 - Unpacking
24 en | Planning Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 4 Planning 4.1 Unpacking Unpack carefully and handle the equipment with care. The packaging contains: – Dinion2X IP camera – CCD protection cap (mounted on camera) – Power conne...
Page 25 - System requirements
Dinion2X IP Camera Planning | en 25 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 4.2 System requirements – Computer with Windows XP/Vista operating system, network access, and Microsoft Internet Explorer web browser version 7.0 or later or – Computer with Wi...
Page 26 - Install players; Tools
26 en | Planning Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 4.3 Install players Play back saved-video sequences using the Player from Bosch Security Systems. This can be found on the DVD-ROM supplied. to play back saved sequences using t...
Page 27 - Installation; Install options
Dinion2X IP Camera Installation | en 27 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 5 Installation 5.1 Network (and power) connector Figure 5.1 Network connection – Connect the camera to a 10/100 Base-T network. – Use screened UTP Category 5e cable with RJ4...
Page 28 - Power connector; DC supply
28 en | Installation Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 5.2 Power connector Figure 5.2 Power connection Connect power from a 24 VAC or 12 VDC class 2 power supply as follows: – Use AWG16 to 22 stranded wire or AWG16 to 26 solid w...
Page 29 - Alarm and relay connector; Pin; Alarm
Dinion2X IP Camera Installation | en 29 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 5.3 Alarm and relay connector Figure 5.3 Alarm and relay connector pins – Max. wire diameter AWG 22-28 for both stranded and solid; cut back 5 mm (0.2 in) of insulation. – A...
Page 30 - Audio In
30 en | Installation Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 5.4 Audio connectors Figure 5.4 Audio connectors Connect audio devices to the Audio In and Audio Out connectors. The unit has full-duplex mono audio. The two-way communicati...
Page 31 - Video service monitor connector
Dinion2X IP Camera Installation | en 31 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 5.5 Video service monitor connector Figure 5.5 Video BNC connector 1. Connect a service monitor to the composite video BNC connector to aid installation. 2. Open the side pa...
Page 32 - Data connector; DATA
32 en | Installation Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 5.6 Data connector Figure 5.6 Data connector pins The data connector is used to connect the control data coming out of the camera to external devices. RS485, RS422, and RS23...
Page 33 - Lens mounting; Note
Dinion2X IP Camera Installation | en 33 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 5.7 Lens mounting The camera accepts CS-mount lenses. C-mount lenses can be mounted using a lens adapter ring. DC-iris lenses are recommended for best picture performance. T...
Page 34 - Mounting the camera
34 en | Installation Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 5.8 Mounting the camera The camera can be mounted either from the top or from the bottom (1/4" 20 UNC thread). Figure 5.9 Mounting a camera CAUTION! The CCD image sensor...
Page 35 - Using the camera install menu; Install; Back focus adjustment
Dinion2X IP Camera Installation | en 35 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 5.9 Using the camera install menu Five keys, located behind the side door panel, are used for accessing the camera menu. To open the install menu press and hold the center k...
Page 36 - Lens adjustment
36 en | Installation Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 3. Press and hold the center key for more than 2 seconds until the Install menu appears. 4. Select Len Wizard and move cursor to the Set Back Focus Now item. 5. Turn the bac...
Page 37 - Lens Wizard
Dinion2X IP Camera Installation | en 37 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 5.11.3 Video-iris lens 1. Unlock the back focus locking button. 2. Access the Lens Wizard menu. 3. Set Back Focus Now is highlighted in the menu. 4. Turn the back focus adju...
Page 38 - Camera menu navigation; Exit
38 en | Camera set-up Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 6 Camera set-up The camera normally provides an optimal picture without the need for further adjustments. Configuration of the camera is carried out remotely via the networ...
Page 39 - Install menu; Traffic
Dinion2X IP Camera Camera set-up | en 39 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 6.2 Install menu When the Install menu is opened, the MAC address of the unit is shown. This is factory set and cannot be changed. (To ensure that the correct MAC address i...
Page 40 - Infrared; Lens Wizard submenu; Item
40 en | Camera set-up Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 6. Infrared Use this mode if the camera is viewing a scene lit by infrared light. 6.2.2 Lens Wizard submenu Item Selection Description Lens type Auto, Manual, DC- iris, Vid...
Page 41 - Network submenu
Dinion2X IP Camera Camera set-up | en 41 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 6.2.3 Network submenu To operate the camera in your network, a network-valid IP address must be assigned. The factory default IP address is 192.168.0.1 The new IP address, ...
Page 42 - Auto
42 en | Camera set-up Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 6.3 Day/Night switching The camera is equipped with a motorized IR filter. The mechanical IR filter can be removed in low-light or IR illuminated applications by software c...
Page 43 - Browser connection; Security
Dinion2X IP Camera Browser connection | en 43 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 7 Browser connection A computer with Microsoft Internet Explorer can be used to receive live images from the camera, control cameras, and replay stored sequences. The ...
Page 44 - Establishing the connection; Password protection in camera; OK; Protected network; Identity
44 en | Browser connection Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 7.2 Establishing the connection The camera must be assigned a valid IP address to operate on your network. The default address pre-set at the factory is 192.168.0.1 1....
Page 45 - Connecting to a hardware decoder; Alarm connection
Dinion2X IP Camera Browser connection | en 45 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 7.4 Connecting to a hardware decoder A compatible H.264 hardware decoder with a monitor can be connected to the camera using an Ethernet network connection. Cameras ar...
Page 46 - Connection established; LIVEPAGE; RECORDINGS; SETTINGS
46 en | Browser connection Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 7.5 Connection established When a connection is established, the LIVEPAGE is initially displayed. The application title bar displays three items: LIVEPAGE , RECORDINGS...
Page 47 - Basic; Advanced Mode
Dinion2X IP Camera Browser connection | en 47 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 the configuration menu is opened. All settings are stored in the camera memory so that they are retained, even if the power is interrupted. Changes that influence the ...
Page 48 - Basic Mode; Basic Mode menu tree; Saving changes
48 en | Basic Mode Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 8 Basic Mode 8.1 Basic Mode menu tree The basic mode configuration menu allows a set of basic camera parameters to be configured. To view the current settings: 1. If necessary...
Page 49 - Device Access; Camera name
Dinion2X IP Camera Basic Mode | en 49 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 8.2 Device Access 8.2.1 Camera name Assign a name to assist in identification. This name simplifies the management of multiple devices in more extensive systems. The name is u...
Page 51 - Network
Dinion2X IP Camera Basic Mode | en 51 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 8.4 Network Use the settings on this page to integrate the device into a network. Some changes only take effect after a reboot. In this case, the Set button changes to Set and...
Page 52 - Encoder Profile; On; Recording; Storage medium; Start; System Overview
52 en | Basic Mode Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 8.5 Encoder Profile Select a profile for encoding the video signal. Pre-programmed profiles are available that give priority to different parameters. When a profile is selecte...
Page 53 - Advanced Mode menu tree
Dinion2X IP Camera Advanced Mode | en 53 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 9 Advanced Mode 9.1 Advanced Mode menu tree The advanced mode configuration menu contains all camera parameters that can be configured. To view the current settings: 1. Cli...
Page 55 - General; Identification
Dinion2X IP Camera Advanced Mode | en 55 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 9.2 General 9.2.1 Identification Camera ID Each device should be assigned a unique identifier that can be entered here as an additional means of identification. Camera name...
Page 58 - Display Stamping
58 en | Advanced Mode Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 9. When finished, click OK to save and activate the table. Time server IP address The camera can receive the time signal from a time server using various time server protoc...
Page 60 - Web Interface; Appearance; Website language
60 en | Advanced Mode Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 9.3 Web Interface 9.3.1 Appearance Adapt the appearance of the web interface and change the website language to meet your requirements. If necessary, replace the company's ...
Page 61 - LIVEPAGE Functions
Dinion2X IP Camera Advanced Mode | en 61 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 9.3.2 LIVEPAGE Functions In this window, adapt the Livepage functions to meet your requirements. Choose from a variety of different options for displaying information and c...
Page 62 - Logging
62 en | Advanced Mode Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems Show system log The system messages are displayed with the date and time in a field next to the video image and provide information about the establishment and termination ...
Page 63 - Encoder; Privacy Masks; Define profiles
Dinion2X IP Camera Advanced Mode | en 63 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 9.4 Encoder 9.4.1 Privacy Masks Four privacy mask areas can be defined. The activated masked areas are filled with the selected pattern in live view. 1. Select the pattern ...
Page 66 - Default
66 en | Advanced Mode Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems The value 9 represents the best image quality with, if necessary, a lower frame refresh rate depending on the settings for the maximum data rate. A value of 51 results in a...
Page 67 - Encoder Streams; Select H.264 Settings
Dinion2X IP Camera Advanced Mode | en 67 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 9.4.3 Encoder Streams Select H.264 Settings 1. Select the codec algorithm for streams 1 and 2. The following algorithms are available – H.264 BP+ (HW decoder) – H.264 MP Lo...
Page 68 - Audio
68 en | Advanced Mode Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems JPEG stream Set the parmeters for the M-JPEG stream. – Select the Max. frame rate in images per second (IPS). – The Picture quality slider allows adjustment of the M-JPEG i...
Page 69 - Camera; Mode
Dinion2X IP Camera Advanced Mode | en 69 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 9.6 Camera If the camera is in monochrome mode, all color-related menu items are disabled and cannot be accessed. 9.6.1 Mode Pre-defined modes The camera has six pre-progra...
Page 70 - ALC
70 en | Advanced Mode Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 5. Low noise Enhancements are set to reduce picture noise. Useful for conditional refresh DVR and IP storage systems because reducing noise reduces the amount of storage re...
Page 73 - Enhance
Dinion2X IP Camera Advanced Mode | en 73 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 A low (negative) value means that the camera switches to monochrome at a lower light level. A high (positive) value means that the camera switches to monochrome at a higher...
Page 74 - Color
74 en | Advanced Mode Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems from each exposure are mixed to give a more detailed image (use 2X Dynamic when SmartBLC is not required). – Smart BLC : BLC window and weighting factor are automatically d...
Page 75 - Installer Options
Dinion2X IP Camera Advanced Mode | en 75 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 – In Manual mode the Red, Green, and Blue gain can be manually set to a desired position. Speed Adjust the speed ( Fast , Medium or Slow ) of the white balance control loop...
Page 77 - Storage Management
Dinion2X IP Camera Advanced Mode | en 77 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 9.7 Recording Record the images from the camera to an appropriately configured iSCSI system. For long-term authoritative images use an appropriately sized iSCSI system. A V...
Page 80 - Recording Profiles
80 en | Advanced Mode Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 9.7.2 Recording Profiles Define up to ten different recording profiles here, then assign these to individual days or times of day on the Recording Scheduler page. Modify th...
Page 81 - Retention Time
Dinion2X IP Camera Advanced Mode | en 81 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 Stream Select the data stream to be used for standard recordings. (You can select the data stream for alarm recordings separately and independently of this setting.) Alarm ...
Page 82 - Recording Scheduler
82 en | Advanced Mode Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 9.7.4 Recording Scheduler The recording scheduler allows you to link the created recording profiles to the days and times at which the camera's images are to be recorded in...
Page 83 - Recording Status
Dinion2X IP Camera Advanced Mode | en 83 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 Profile names Change the names of the recording profiles listed in the Time periods box. 1. Click a profile. 2. Click Rename . 3. Enter the new name and click Rename again....
Page 84 - Alarm Connections
84 en | Advanced Mode Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 9.8 Alarm 9.8.1 Alarm Connections Select the response of the camera when an alarm occurs. In the event of an alarm, the device can automatically connect to a pre-defined IP...
Page 88 - VCA configuration- Profiles
88 en | Advanced Mode Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 9.8.3 VCA configuration- Profiles Configure two profiles with different VCA configurations. Save profiles on your computer's hard drive and load saved profiles from there. ...
Page 89 - Motion detector
Dinion2X IP Camera Advanced Mode | en 89 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 Metadata is always created for a video content analysis, unless this was explicitly excluded. Depending on the analysis type selected and the relevant configuration, additi...
Page 94 - VCA configuration - Scheduled
94 en | Advanced Mode Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 9.8.4 VCA configuration - Scheduled A scheduled configuration allows you to link a VCA profile with the days and times at which the video content analysis is to be active. ...
Page 96 - VCA configuration - Event triggered; Trigger
96 en | Advanced Mode Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 9.8.5 VCA configuration - Event triggered This configuration allows you to stipulate that the video content analysis is only to be activated when triggered by an event. As ...
Page 97 - Audio Alarm
Dinion2X IP Camera Advanced Mode | en 97 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 9.8.6 Audio Alarm Create alarms based on audio signals. Configure signal strengths and frequency ranges so that false alarms, for example, machine noise or background noise...
Page 99 - Destination address; Sender name; Send Now
Dinion2X IP Camera Advanced Mode | en 99 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 Destination address Enter the e-mail address for alarm e-mails here. The maximum address length is 49 characters. Sender name Enter a unique name for the e-mail sender, for...
Page 100 - Alarm Task Editor
100 en | Advanced Mode Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 9.8.8 Alarm Task Editor Editing scripts on this page overwrites all settings and entries on the other alarm pages. This procedure cannot be reversed. To edit this page, yo...
Page 101 - Interfaces; Alarm input
Dinion2X IP Camera Advanced Mode | en 101 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 9.9 Interfaces 9.9.1 Alarm input Configure the alarm triggers for the camera. Select N.C. (Normally Closed) if the alarm is to be triggered by closing the contact. Select ...
Page 103 - Set
Dinion2X IP Camera Advanced Mode | en 103 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 9.10 Network 9.10.1 Network The settings on this page are used to integrate the device into a network. Some changes only take effect after a reboot. In this case Set chang...
Page 107 - Advanced
Dinion2X IP Camera Advanced Mode | en 107 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 9.10.2 Advanced The settings on this page are used to set advanced settings the network. Some changes only take effect after a reboot. In this case Set changes to Set and ...
Page 108 - RTSP port; Multicasting; Enable
108 en | Advanced Mode Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems RTSP port If necessary, select a different port for the exchange of the RTSP data from the list. The standard RTSP port is 554. Select Off to deactivate the RTSP function....
Page 109 - JPEG Posting
Dinion2X IP Camera Advanced Mode | en 109 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 setting 0.0.0.0 the encoder for the stream operates in multi- unicast mode (copying of data stream in device). The camera supports multi-unicast connections for up to five...
Page 110 - Posting interval; Encryption
110 en | Advanced Mode Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems correctly . For eample, the file snap011005_114530.jpg was stored on October 1, 2005 at 11.45 and 30 seconds. Posting interval Enter the interval in seconds at which the i...
Page 111 - Service; Maintenance; Firmware
Dinion2X IP Camera Advanced Mode | en 111 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 9.11 Service 9.11.1 Maintenance Firmware The camera functions and parameters can be updated by uploading new firmware. To do this, the latest firmware package is transferr...
Page 113 - Maintenance log; Licenses
Dinion2X IP Camera Advanced Mode | en 113 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 Once all files have been successfully uploaded, the device must be rebooted. In the address field of the browser, enter /reset after the camera's IP address, for example: ...
Page 114 - Processor load
114 en | Operation via the browser Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 10 Operation via the browser 10.1 Livepage After the connection is established, the Livepage is initially displayed. It shows the live video image on the right...
Page 115 - Image selection; Stream 1; View Control; System Log; Saving snapshots
Dinion2X IP Camera Operation via the browser | en 115 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 10.1.2 Image selection View the image on a full screen. – Click the Stream 1 , Stream 2 or M-JPEG tab below the video image to switch between the different dis...
Page 116 - Recording video sequences; Running recording program; Audio communication
116 en | Operation via the browser Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems – Click the camera icon to save single images. The storage location depends on the configuration of the camera. 10.1.7 Recording video sequences Sections of th...
Page 117 - Recordings page; Controlling playback
Dinion2X IP Camera Operation via the browser | en 117 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 10.2 Recordings page Access the Recordings page for playing back recorded video sequences from the Livepage as well as from the Settings menu. The Recordings l...
Page 118 - Slide control
118 en | Operation via the browser Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems Control playback by means of the buttons below the video image. The buttons have the following functions: Start/Pause playback Jump to start of active sequence...
Page 119 - Troubleshooting; Function test
Dinion2X IP Camera Troubleshooting | en 119 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 11 Troubleshooting 11.1 Function test The camera offers a variety of configuration options. Therefore, check that it works properly after installation and configuration....
Page 120 - Resolving problems; Malfunction
120 en | Troubleshooting Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 11.2 Resolving problems The following table is intended to help identify the causes of malfunctions and correct them where possible. Malfunction Possible causes Solution...
Page 122 - Customer service; POWER
122 en | Troubleshooting Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 11.3 Customer service If a fault cannot be resolved, please contact your supplier or system integrator, or go directly to Bosch Security Systems Customer Service. The ve...
Page 123 - Testing the network connection; Data Terminal
Dinion2X IP Camera Maintenance | en 123 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 12 Maintenance 12.1 Testing the network connection The ping command can be used to check the connection between two IP addresses. This allows testing whether a device is act...
Page 124 - Configuring the Terminal
124 en | Maintenance Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems Configuring the Terminal Before the terminal program can communicate with the camera, the transmission parameters must be matched. Make the following settings for the termin...
Page 125 - Reboot; Repairs; Transfer and disposal
Dinion2X IP Camera Maintenance | en 125 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 Note: You must reboot to activate the new IP address, a new subnet mask or a gateway IP address. Reboot Briefly interrupt the power supply to the camera for a reboot (discon...
Page 126 - Technical Data; Specifications; Type number
126 en | Technical Data Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 13 Technical Data 13.1 Specifications Type number NBN-498 Imager 1/3-inch CCD sensor Active pixels (PAL) 752x582 Active pixels (NTSC) 768x494 Rated supply voltage 12 VDC,...
Page 129 - Dimensions
Dinion2X IP Camera Technical Data | en 129 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 13.1.1 Dimensions Figure 13.1 Side and front dimensions (2.283)58 (1.339) 34 (3.346) 85 (4.646) 118 (4.803) 122 (1.889) 48 (2.598) 66 1/4"-20 UNC 1/4"-20 UNC mm (...
Page 130 - Accessories; Recommended lenses
130 en | Technical Data Dinion2X IP Camera AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems 13.1.2 Accessories Recommended lenses LTC 3364/21 Varifocal Lens IR corrected – 1/3-inch, 2.8 – 6 mm, DC-iris, CS-mount F1.4-200, 4-pin LTC 3664/30 Varifocal Lens IR corr...
Page 131 - Glossary
Dinion2X IP Camera Glossary | en 131 Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06 Glossary 0…9 10/100Base-TIEEE-802.3 specification for 10 or 100 Mbps Ethernet. 802.1x The IEEE 802.1x standard provides a general method for authentication and authorization in...