Page 3 - Table of Contents; Safety
IP Camera 200 Series Table of Contents | en 3 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 Table of Contents 1 Safety 8 1.1 Safety precautions 8 1.2 Important safety instructions 9 1.3 FCC & ICES compliance 10 1.4 UL certification 11 1.5 CE certificatio...
Page 4 - Basic Mode
4 en | Table of Contents IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 5 Basic Mode 64 5.1 Basic Mode menu tree 64 5.2 Device Access 65 5.2.1 Camera name 65 5.2.2 Password 65 5.3 Date/Time 66 5.4 Network 67 5.5 Encoder 68 5.6 Audio 68 5....
Page 5 - Operation via the browser
IP Camera 200 Series Table of Contents | en 5 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 6.6.1 Alarm Connections 101 6.6.2 Video Content Analyses (VCA) 104 6.6.3 VCA configuration- Profiles 105 6.6.4 VCA configuration - Scheduled 111 6.6.5 VCA configurati...
Page 6 - Maintenance
6 en | Table of Contents IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 8.3 Customer service 141 9 Maintenance 142 9.1 Repairs 142 9.1.1 Transfer and disposal 142 10 Technical Data 143 10.1 Specifications 143 10.1.1 Dimensions 157 10.1.2 ...
Page 7 - Safety precautions
8 en | Safety IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 1 Safety 1.1 Safety precautions DANGER! High risk: This symbol indicates an imminently hazardous situation such as "Dangerous Voltage" inside the product. If not avoided...
Page 8 - Important safety instructions; Controls adjustment -
IP Camera 200 Series Safety | en 9 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 1.2 Important safety instructions Read, follow, and retain for future reference all of the following safety instructions. Heed all warnings on the unit and in the operating inst...
Page 9 - FCC & ICES compliance; FCC & ICES Information; FCC Rules; residential
10 en | Safety IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 1.3 FCC & ICES compliance FCC & ICES Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of...
Page 10 - How to Identify; FCC RF Radiation Exposure Statement; UL certification; Disclaimer; Circuit Television Equipment, UL 2044
IP Camera 200 Series Safety | en 11 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 The user may find the following booklet, prepared by the Federal Communications Commission, helpful: How to Identify and Resolve Radio-TV Interference Problems . This booklet i...
Page 11 - CE certification; More information; European
12 en | Safety IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 1.5 CE certification This indicates compliance with the R&TTE Directive 1999/5/EC and meets the relevant parts of following technical specifications: ETSI EN 300 328 V1.7.1...
Page 12 - Copyrights
IP Camera 200 Series Safety | en 13 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 1.7 Copyrights The firmware 4.1 uses the fonts "Adobe-Helvetica-Bold-R- Normal--24-240-75-75-P-138-ISO10646-1" and "Adobe- Helvetica-Bold-R-Normal--12-120-75-75-P-7...
Page 13 - Introduction; Features; SD/SDHC card slot supports edge recording up to 32 GB
14 en | Introduction IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 2 Introduction 2.1 Features This WLAN HD 720p IP camera is a ready-to-use, complete network video surveillance system inside a compact camera. The camera offers a cost-ef...
Page 14 - Unpacking
IP Camera 200 Series Introduction | en 15 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 2.2 Unpacking Unpack carefully and handle the equipment with care. The packaging contains: – IP camera with lens – Universal power supply with US, EU and UK plug – Camera...
Page 15 - Installation; Screw the antenna onto the screw connector on the rear of
18 en | Installation IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 3 Installation 3.1 Wireless antenna Figure 3.1 Wireless antenna 1. Screw the antenna onto the screw connector on the rear of the camera. 2. Straighten the antenna.
Page 16 - Unscrew the cover on the right side of the camera.
IP Camera 200 Series Installation | en 19 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 3.2 SD card Figure 3.2 SD card 1. Unscrew the cover on the right side of the camera. 2. Slide the SD card into the slot. 3. Close and secure the cover. The camera support...
Page 17 - Mounting the camera; The camera can be mounted either from the top or from the; Use three screws to secure the base of the mounting unit
20 en | Installation IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 3.3 Mounting the camera The camera can be mounted either from the top or from the bottom (1/4"-20 UNC thread). The mounting socket is isolated from ground to prevent ...
Page 18 - Adjust the ball-socket so that camera mount is correcrly
IP Camera 200 Series Installation | en 21 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 3. Adjust the ball-socket so that camera mount is correcrly aligned for the required angle. 4. Screw camera onto mount and, when in position, tighten the locking ring (1)...
Page 19 - Network connector; Use a shielded UTP Category 5e cable with RJ45
22 en | Installation IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 3.4 Network connector Figure 3.4 Network connection – Connect the camera to a 10/100 Base-T network. – Use a shielded UTP Category 5e cable with RJ45 connectors. 1 2 3 4 ...
Page 20 - Power connection
IP Camera 200 Series Installation | en 23 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 3.5 Power connection 3.5.1 DC power connection Figure 3.5 DC power connection 1. Slide the plug adapter that matches your outlet socket onto the supplied power supply. 2....
Page 21 - Function
24 en | Installation IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 3.6 I/O connector Figure 3.6 I/O connector pins – Max. wire diameter AWG 22-28 for both stranded and solid; cut back 5 mm (0.2 in) of insulation. – Relay output switching...
Page 22 - Connect audio devices to the; Line In; and; Line Out
IP Camera 200 Series Installation | en 25 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 3.7 Audio connectors Figure 3.7 Audio connectors Connect audio devices to the Line In and Line Out connectors. 1 2 3 4 DC12V Etherne t Line-out Rese t Line-in I/O Line - ...
Page 23 - Resetting the camera; If the camera cannot be connected because the IP address has
26 en | Installation IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 3.8 Resetting the camera If the camera cannot be connected because the IP address has changed, press and hold the reset button (7 seconds approximately) until the LED fla...
Page 24 - Browser connection; System requirements; Security
IP Camera 200 Series Browser connection | en 59 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 4 Browser connection A computer with Microsoft Internet Explorer can be used to receive live images from the camera, control cameras, and replay stored sequences. T...
Page 25 - Establishing the connection; Password protection in camera; OK; Protected network; Identity
60 en | Browser connection IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 4.2 Establishing the connection The camera must be assigned a valid IP address to operate on your network. The default address pre-set at the factory is 192.168.0.1...
Page 26 - Connection established; Livepage
IP Camera 200 Series Browser connection | en 61 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 4.4 Connection established When a connection is established, the LIVEPAGE is initially displayed. The application title bar displays the type number of the connecte...
Page 27 - Basic; Section 5 Basic Mode, page 64; Advanced Mode
62 en | Browser connection IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems the configuration menu is opened. All settings (except date/ time) are stored in the camera memory so that they are retained, even if the power is interrupted. Chan...
Page 28 - Basic Mode; Basic Mode menu tree
64 en | Basic Mode IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 5 Basic Mode 5.1 Basic Mode menu tree The basic mode configuration menu allows a set of basic camera parameters to be configured. To view the current settings: 1. If necess...
Page 29 - Device Access; Camera name
IP Camera 200 Series Basic Mode | en 65 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 5.2 Device Access 5.2.1 Camera name The camera can be assigned a name to assist in identifying it. The name simplifies the management of multiple devices in more extensive ...
Page 30 - Confirm password
66 en | Basic Mode IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems Confirm password Re-enter the new password to ensure that there are no typing mistakes. The new password is only saved after clicking Set . Therefore, click Set immediately...
Page 31 - Network
IP Camera 200 Series Basic Mode | en 67 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 5.4 Network Use the settings on this page to integrate the device into a network. Some changes only take effect after a reboot. In this case, the Set button changes to Set ...
Page 32 - Encoder; Storage medium; System Overview
68 en | Basic Mode IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 5.5 Encoder Select a profile for encoding the video signal. Pre-programmed profiles are available that give priority to different parameters. When a profile is selected, it...
Page 33 - Advanced Mode menu tree
IP Camera 200 Series Advanced Mode | en 69 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 6 Advanced Mode 6.1 Advanced Mode menu tree The advanced mode configuration menu contains all camera parameters that can be configured. To view the current settings: 1. ...
Page 34 - General; Identification
70 en | Advanced Mode IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 6.2 General 6.2.1 Identification Camera ID Each camera should be assigned a unique identifier that can be entered here as an additional means of identification. Camera n...
Page 37 - Display Stamping
IP Camera 200 Series Advanced Mode | en 73 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 5. Click one of the entries in the table to make changes. The entry is highlighted. 6. Click Delete to remove the entry from the table. 7. Choose other values from the l...
Page 39 - Web Interface; Appearance; Website language
IP Camera 200 Series Advanced Mode | en 75 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 6.3 Web Interface 6.3.1 Appearance Adapt the appearance of the web interface and change the website language to meet your requirements. If necessary, replace the company...
Page 40 - LIVEPAGE Functions
76 en | Advanced Mode IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 6.3.2 LIVEPAGE Functions In this window, adapt the Livepage functions to meet your requirements. Choose from a variety of different options for displaying information an...
Page 41 - Logging
IP Camera 200 Series Advanced Mode | en 77 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 Allow snapshots Specify whether the icon for saving individual images should be displayed below the live image. Individual images can only be saved if this icon is visib...
Page 42 - Camera; Installer Menu
78 en | Advanced Mode IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 6.4 Camera 6.4.1 Installer Menu Camera LED Disable the Camera LED on the camera to switch it off. Mirror image Enable Mirror image to obtain a vertically flipped image (...
Page 43 - Picture Settings; White balance
IP Camera 200 Series Advanced Mode | en 79 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 Note: Shutter time is affected by frame rate in auto framerate mode. For example, if the frame rate is 30 IPS, the longest shutter time available is 1/30s. 6.4.2 Picture...
Page 44 - Click; Default; to set all video values to their factory setting.
80 en | Advanced Mode IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems Default Click Default to set all video values to their factory setting.
Page 45 - Encoder Streams
IP Camera 200 Series Advanced Mode | en 81 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 6.4.3 Encoder Streams Select H.264 Settings 1. The codec algorithm for stream 1 is always: – H.264 MP 720p25/30 fixed 2. Select the codec algorithm for stream 2. The fol...
Page 46 - Audio
82 en | Advanced Mode IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems Note: The M-JPEG resolution follows the highest resolution setting of either stream 1 or stream 2. For example, if stream 1 is VGA and stream 2 is QVGA, the JPEG resolut...
Page 47 - Recording; VRM
IP Camera 200 Series Advanced Mode | en 83 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 6.5 Recording Record the images from the camera to local storage media or to an appropriately configured iSCSI system. SDHC cards are the ideal solution for shorter stor...
Page 48 - Storage Management
84 en | Advanced Mode IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems further information, contact your local customer service at Bosch Security Systems. 6.5.1 Storage Management Device manager If the VRM option is activated, the VRM Video...
Page 51 - Recording Profiles
IP Camera 200 Series Advanced Mode | en 87 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 6.5.2 Recording Profiles Define up to ten different recording profiles here, then assign these to individual days or times of day on the Recording Scheduler page. Modify...
Page 53 - Retention Time; Recording 1
IP Camera 200 Series Advanced Mode | en 89 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 6.5.3 Retention Time Specify the retention times for recordings. If the available memory capacity of a medium has been used, older recordings are only overwritten if the...
Page 54 - Recording Scheduler
90 en | Advanced Mode IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 6.5.4 Recording Scheduler The recording scheduler allows you to link the created recording profiles to the days and times at which the camera's images are to be recorded...
Page 55 - Recording Status
IP Camera 200 Series Advanced Mode | en 91 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 Profile names To change the names of the recording profiles listed in the Time periods box: 1. Click a profile. 2. Click Rename . 3. Enter the new name and click Rename ...
Page 56 - Alarm; Alarm Connections
92 en | Advanced Mode IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 6.6 Alarm 6.6.1 Alarm Connections Select the response of the camera when an alarm occurs. In the event of an alarm, the device can automatically connect to a pre-defined...
Page 60 - VCA configuration- Profiles
96 en | Advanced Mode IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 6.6.3 VCA configuration- Profiles Configure two profiles with different VCA configurations. Save profiles on your computer's hard drive and load saved profiles from ther...
Page 61 - Analysis type
IP Camera 200 Series Advanced Mode | en 97 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 Analysis type Select the required analysis algorithm. By default, only Motion+ is available — this offers a motion detector and essential recognition of tampering. Metad...
Page 66 - VCA configuration - Scheduled
102 en | Advanced Mode IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 6.6.4 VCA configuration - Scheduled A scheduled configuration allows you to link a VCA profile with the days and times at which the video content analysis is to be acti...
Page 67 - . The item is deleted from the table and the
IP Camera 200 Series Advanced Mode | en 103 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 3. Click OK . The item is deleted from the table and the window closes. 4. The process must be repeated for deleting additional days.
Page 68 - VCA configuration - Event triggered; Trigger
104 en | Advanced Mode IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 6.6.5 VCA configuration - Event triggered This configuration allows you to stipulate that the video content analysis is only to be activated when triggered by an event....
Page 69 - Audio Alarm
IP Camera 200 Series Advanced Mode | en 105 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 6.6.6 Audio Alarm Create alarms based on audio signals. Configure signal strengths and frequency ranges so that false alarms, for example, machine noise or background n...
Page 71 - Destination address; Enter the e-mail address for alarm e-mails here. The maximum; Sender name; location of the device. This makes it easier to identify the origin; Send Now; immediately created and sent.
IP Camera 200 Series Advanced Mode | en 107 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 Destination address Enter the e-mail address for alarm e-mails here. The maximum address length is 49 characters. Sender name Enter a unique name for the e-mail sender,...
Page 72 - Interfaces; Alarm input
108 en | Advanced Mode IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 6.7 Interfaces 6.7.1 Alarm input Configure the alarm trigger for the camera. Select N.C. (Normally Closed) if the alarm is to be triggered by opening the contact. Selec...
Page 74 - Network Access
110 en | Advanced Mode IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 6.8 Network 6.8.1 Network Access The settings on this page are used to integrate the device into a network. Some changes only take effect after a reboot. In this case S...
Page 78 - Advanced
114 en | Advanced Mode IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 6.8.2 Advanced The settings on this page are used to set advanced settings the network. Some changes only take effect after a reboot. In this case Set changes to Set an...
Page 79 - WLAN; . Reboot and remove Ethernet cable immediately
IP Camera 200 Series Advanced Mode | en 115 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 RTSP port If necessary, select a different port for the exchange of the RTSP data from the list. The standard RTSP port is 554. Select Off to deactivate the RTSP functi...
Page 80 - Multicast; Enable
116 en | Advanced Mode IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 6.8.4 Multicast In addition to a one-to-one connection between a camera and a single receiver (unicast), the camera can enable multiple receivers to receive the video s...
Page 81 - FTP Posting
IP Camera 200 Series Advanced Mode | en 117 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 Duplication of data places a heavy demand on the CPU and can lead to impairment of the image quality under certain circumstances. Port Enter the port address for the st...
Page 82 - FTP server IP address; Enter the IP address of the FTP server on which to save the; FTP server login; Enter your login name for the FTP server.; FTP server password; Enter the password that gives access to the FTP server.; Path on FTP server; Enter an exact path to post the images on the FTP server.
118 en | Advanced Mode IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems FTP server IP address Enter the IP address of the FTP server on which to save the JPEG images. FTP server login Enter your login name for the FTP server. FTP server pas...
Page 83 - Service; Firmware
IP Camera 200 Series Advanced Mode | en 119 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 6.9 Service 6.9.1 Maintenance Firmware The camera functions and parameters can be updated by uploading new firmware. To do this, the latest firmware package is transfer...
Page 85 - Maintenance log
IP Camera 200 Series Advanced Mode | en 121 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 Maintenance log Download an internal maintenance log from the device to send it to Customer Service for support purposes. Click Download and select a storage location f...
Page 86 - Processor load
132 en | Operation via the browser IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 7 Operation via the browser 7.1 Livepage After the connection is established, the Livepage is initially displayed. It shows the live video image on the righ...
Page 87 - Image selection
IP Camera 200 Series Operation via the browser | en 133 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 7.1.2 Image selection View the image on a full screen. – Click the Stream 1 , Stream 2 or M-JPEG tab below the video image to switch between the different d...
Page 88 - System Log / Event Log; System Log
134 en | Operation via the browser IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 7.1.3 Digital I/O Depending on the configuration of the unit, the alarm input and the relay output are displayed next to the camera image. The alarm symbol ...
Page 89 - Saving snapshots; Recording video sequences; Running recording program; Audio communication
IP Camera 200 Series Operation via the browser | en 135 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 7.1.5 Saving snapshots Individual images from the video sequence that is currently being shown on the Livepage can be saved in JPEG format on the computer's...
Page 90 - All connected users receive audio signals sent from the camera
136 en | Operation via the browser IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems All connected users receive audio signals sent from the camera but only the user who first pressed the F12 key can send audio signals; others must wait for ...
Page 91 - Recordings page; Controlling playback
IP Camera 200 Series Operation via the browser | en 137 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 7.2 Recordings page Click Recordings to access the Recordings page from the Livepage or Settings page (the Recordings link is only visible if a storage medi...
Page 92 - Slide control
138 en | Operation via the browser IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems – If required, drag the green arrow to the point in time at which the playback should begin. – Red bars indicate the points in time where alarms were trigge...
Page 93 - Troubleshooting; LED indicators; Power LED; Resolving problems; Malfunction
140 en | Troubleshooting IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 8 Troubleshooting 8.1 LED indicators The camera has LEDs on the front and the rear panel that show the operating status and can indicate possible malfunctions. Power ...
Page 94 - version numbers of the firmware and other status information; menu. Note down this information and the information found
IP Camera 200 Series Troubleshooting | en 141 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 version numbers of the firmware and other status information can be seen when the unit starts or by opening the Service menu. Note down this information and the infor...
Page 95 - Repairs; Transfer and disposal
142 en | Maintenance IP Camera 200 Series AR18-10-B012 | v1.54 | 2011.08 Installation and Operation Manual Bosch Security Systems 9 Maintenance 9.1 Repairs 9.1.1 Transfer and disposal The camera should only be passed-on together with this installation guide. The unit contains environmentally hazardo...
Page 96 - Technical Data; Specifications
IP Camera 200 Series Technical Data | en 143 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 10 Technical Data 10.1 Specifications Input voltage +12 VDC Power consumption 4.6 W (max) Sensor type ¼-inch CMOS Sensor pixels 1280 x 800 Sensitivity 0.3 lux Video re...
Page 98 - Accessories; Contact a Bosch representative in your area for the latest
IP Camera 200 Series Technical Data | en 145 Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.54 | 2011.08 10.1.1 Dimensions Figure 10.1 Dimensions 10.1.2 Accessories LTC 9348/00 Series Indoor Dome – housings for cameras/lens to 216 mm (8.5 in), ceiling mount, tinted, metal...