Teledyne Trace Oxygen Analyzer - Manual

Teledyne Trace Oxygen Analyzer

Teledyne Trace Oxygen Analyzer – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
Page: / 78

Table of Contents:

  • Page 2 – i i; Teledyne Analytical Instruments; Copyright © 1999 Teledyne Analytical Instruments
  • Page 3 – iii; Trace Oxygen Analyzer; Instrument configured for Vacuum Service
  • Page 4 – i v; Model 3000TA-XL-EU complies with all of the requirements of; GROUND
  • Page 5 – System
  • Page 6 – v i; Alarms; Maintenance
  • Page 7 – vii
  • Page 8 – viii; COMBUSTIBLE GAS USAGE WARNING; DANGER
  • Page 9 – Introduction; Typical Applications
  • Page 10 – Model Designations
  • Page 12 – Analyze
  • Page 13 – The rear panel, shown in Figure 1-2, contains the gas and electrical; Power Connection; Universal AC power source.; Gas Inlet and Outlet; One inlet and one exhaust out.; Analog Outputs
  • Page 14 – Note: If you require highly accurate Auto-Cal timing, use external
  • Page 15 – Operational Theory; The analyzer is composed of three subsystems:
  • Page 16 – The Micro-Fuel Cell is a cylinder only 11⁄4 inches in diameter and 11⁄4
  • Page 17 – Pb
  • Page 18 – (These reactions are specific to oxygen as long as no gaseous compo-
  • Page 19 – The Model 3000TA-XL sample system is designed and fabricated to
  • Page 20 – TOP
  • Page 22 – Electronics and Signal Processing; The Model 3000TA-XL Trace Oxygen Analyzer uses an 8031 micro-
  • Page 23 – Figure 2-7: Block Diagram of the Model 3000TA-XL Electronics; In the presence of oxygen the cell generates a current. A current to
  • Page 24 – Signals from the power supply are also monitored, and through the
  • Page 25 – Installation; Installation of the Model 3000TA-XL Analyzer includes:; Unpacking the Analyzer; The Model 3000TA-XL is for indoor use in a general purpose area. It
  • Page 26 – Figure 3-2: Required Front Door Clearance; Rear Panel Connections; Figure 3-3 shows the Model 3000TA-XL rear panel. There are ports
  • Page 27 – NOTE: Do not remove plastic caps on VCR fittings, unless you are; SAMPLE IN
  • Page 28 – CAUTION: Power is applied to the instrument's circuitry as; 0-Pin Equipment Interface Connector
  • Page 29 – Figure 3-4: Equipment Interface Connector Pin Arrangement; There are four DC output signal pins—two pins per; Pin; The nine alarm-circuit connector pins connect to the
  • Page 30 – Pin Contact; Remote Calibration Protocol
  • Page 31 – Span; Table 3-3: Remote Calibration Connections
  • Page 32 – Note: The Remote Valve connections (described below) provides
  • Page 35 – Testing the System
  • Page 37 – Operation; Enter
  • Page 38 – Using the Data Entry and Function; ΔΔΔΔΔ∇
  • Page 39 – Function; The subfuctions of the; PSWD; Security can be established by choosing a 5 digit; Figure 4-1: Hierarchy of Functions and Subfunctions
  • Page 40 – TETAI; Logout; More; Self–Test
  • Page 41 – tion
  • Page 42 – Auto—Cal
  • Page 44 – Entering the Password; Characters Available for Password Definition:
  • Page 46 – OK; Version Self—Test
  • Page 47 – Calibration of the Analyzer; Span Gas Calibration; The recommended span gas concentration is between 7.0 to 9.0 ppm; Air Calibration; The user may decide to eliminate the zero offset for improved accu-
  • Page 49 – Slope; Cell Failure
  • Page 50 – automatic
  • Page 51 – AUTO
  • Page 52 – automatically; Switching of Sample Streams
  • Page 54 – Alarm
  • Page 55 – Range
  • Page 56 – Front Panel
  • Page 57 – Rear Panel; Voltage Signal
  • Page 58 – The analog output signal has a voltage which depends on the oxygen; LO
  • Page 59 – Routine Maintenance; Calibration; Storing and Handling Replacement Cells; To have a replacement cell available when it is needed, TAI recom-
  • Page 60 – CAUTION: Do not disturb the integrity of the cell package until
  • Page 61 – Remove power to the instrument by unplugging the power cord
  • Page 62 – Before installing a new cell, check the O-ring in the base of the cell; Note: There is a small location hole drilled in the holder. This hole; With O-ring in place, align the guide pin with the hole on the cell; The B-2CXL cell is not designed for applications where CO; Note: Evidence of damage due to tampering or mishandling will
  • Page 63 – Place small screwdriver in notch, and pry cover off, as shown in; Figure 5-2: Removing Fuse Block from Housing; To change between American and European fuses, remove the
  • Page 64 – System Self Diagnostic Test; Power; Major Internal Components
  • Page 65 – Power Supply; See the drawings in the Drawings section in back of this manual; xxxxx
  • Page 66 – Possible Cause; Problem
  • Page 67 – Appendix; Packaging: General Purpose; • Flush panel mount (Standard
  • Page 71 – A usable flow rate for a 3000XL series analyzer is one which can be; CELL PRESSURE CONCERNS:
  • Page 72 – To improve the system response, a by-pass can be added to increase
  • Page 74 – A-6 Material Safety Data Sheet; Section I – Product Identification; Quantity
  • Page 75 – Section IV – Fire and Explosion Hazard Data; Section VI – Health Hazard Data
  • Page 76 – Section VII – Precautions for Safe Handling and Use
  • Page 77 – Section VIII – Control Measures; Section IX – Disposal; Section X – References
  • Page 78 – A7 - Installling and Replacing a new Insta-Trace; Read completely before beginning the procedure
Loading the manual

i

Trace Oxygen Analyzer

Teledyne Analytical Instruments

OPERATING INSTRUCTIONS FOR

Model 3000TA-XL-EU

Trace Oxygen Analyzer

HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING
SYSTEM.
PERSONAL PROTECTIVE EQUIPMENT MAY BE REQUIRED WHEN SERVICING THIS SYSTEM.
HAZARDOUS VOLTAGES EXIST ON CERTAIN COMPONENTS INTERNALLY WHICH MAY PERSIST
FOR A TIME EVEN AFTER THE POWER IS TURNED OFF AND DISCONNECTED.
ONLY AUTHORIZED PERSONNEL SHOULD CONDUCT MAINTENANCE AND/OR SERVICING. BEFORE
CONDUCTING ANY MAINTENANCE OR SERVICING CONSULT WITH AUTHORIZED SUPERVISOR/
MANAGER.

DANGER

P/N M69603

11/24/04

ECO # 03-0126

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - i i; Teledyne Analytical Instruments; Copyright © 1999 Teledyne Analytical Instruments

i i Model 3000TA-XL-EU Teledyne Analytical Instruments Copyright © 1999 Teledyne Analytical Instruments All Rights Reserved. No part of this manual may be reproduced, transmitted, tran- scribed, stored in a retrieval system, or translated into any other language or computerlanguage in whole or in pa...

Page 3 - iii; Trace Oxygen Analyzer; Instrument configured for Vacuum Service

iii Trace Oxygen Analyzer Teledyne Analytical Instruments Specific Model Information The instrument for which this manual was supplied may incorporate one or more options not supplied in the standard instrument. Commonly availableoptions are listed below, with check boxes. Any that are incorporated ...

Page 4 - i v; Model 3000TA-XL-EU complies with all of the requirements of; GROUND

i v Model 3000TA-XL-EU Teledyne Analytical Instruments Model 3000TA-XL-EU complies with all of the requirements of the Commonwealth of Europe (CE) for Radio Frequency Interfer-ence, Electromagnetic Interference (RFI/EMI), and Low VoltageDirective (LVD). The following International Symbols are used t...

Other Teledyne Models

All Teledyne Other