Teledyne 212R - Manual

Teledyne 212R

Teledyne 212R – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
Page: / 28

Table of Contents:

  • Page 2 – Teledyne Analytical Instruments; Thermal Conductivity Analyzer Model 212R
  • Page 5 – INTRODUCTION
  • Page 6 – signal of 0.25 microvolts will be sensed by the analyzer.
  • Page 7 – electrical output signal into readable information.
  • Page 9 – vacuum tubes are firmly seated in their respective sockets.
  • Page 11 – Make sure to close the cylinder prior to bleeding the first stage
  • Page 12 – STARTUP
  • Page 13 – Turn the analyzer and recorder power switches to “ON”.
  • Page 14 – valve that is located downstream
  • Page 15 – NOTE: TAI recommends that some bypass flow be permitted
  • Page 17 – Due to the delicate balance of the thermal conductivity cell
  • Page 18 – Loss of Zero Control.
  • Page 21 – ) Sample gas with a moisture content of 10 ppm or greater. Again, the
  • Page 22 – CAUTION: Do not insert the tubing along the edges of the
  • Page 23 – Unless competent electronic technicians are available, TAI
  • Page 24 – CAUTION: Do not touch the thermistor probe with the iron. The
  • Page 26 – NOTE: Cylinder and sample stream pressure settings must
  • Page 27 – Orders should be sent to:; Drawing List; Orders for replacement parts should include the art
  • Page 28 – APPENDIX
Loading the manual

Teledyne Analytical Instruments

1

Thermal Conductivity Analyzer Model 212R

I

NSTRUCTION

M

ANUAL

M

ODEL

212R

T

HERMAL

C

ONDUCTIVITY

A

NALYZER

HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM.

PERSONAL PROTECTIVE EQUIPMENT MAY BE REQUIRED WHEN SERVICING THIS SYSTEM.

HAZARDOUS VOLTAGES EXIST ON CERTAIN COMPONENTS INTERNALLY WHICH MAY PERSIST FOR A
TIME EVEN AFTER THE POWER IS TURNED OFF AND DISCONNECTED.

ONLY AUTHORIZED PERSONNEL SHOULD CONDUCT MAINTENANCE AND/OR SERVICING. BEFORE
CONDUCTING ANY MAINTENANCE OR SERVICING CONSULT WITH AUTHORIZED SUPERVISOR/MANAGER.

DANGER

P/N M73212

11/29/07

ECO # 07-0182

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Teledyne Analytical Instruments; Thermal Conductivity Analyzer Model 212R

Teledyne Analytical Instruments 2 Thermal Conductivity Analyzer Model 212R All Rights Reserved. No part of this manual may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any other language or computerlanguage in whole or in part, in any form or by any means...

Page 5 - INTRODUCTION

Teledyne Analytical Instruments 5 Thermal Conductivity Analyzer Model 212R 1. INTRODUCTION 1.1 Method of Analysis. The Model 212R compares the thermal conductivity of a sample gas to that of a fixed composition reference gas and produces an electrical outputsignal that is calibrated to represent the...

Page 6 - signal of 0.25 microvolts will be sensed by the analyzer.

Teledyne Analytical Instruments 6 Thermal Conductivity Analyzer Model 212R 1.2 Sensitivity. Differences in thermal conductivity that produce a measuring bridge error signal of 0.25 microvolts will be sensed by the analyzer. 1.3 Stability. Internal variables, other than the sample gas, that could pro...

Other Teledyne Models

All Teledyne Other