Teledyne 3300PA - Manual

Teledyne 3300PA

Teledyne 3300PA – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
Page: / 36

Table of Contents:

  • Page 2 – Copyright © 1999 Teledyne Analytical Instruments
  • Page 3 – Contents; Introduction
  • Page 4 – Maintenance
  • Page 5 – Teledyne Analytical Instruments; COMBUSTIBLE GAS USAGE WARNING; DANGER
  • Page 6 – This page left intentionally blank
  • Page 7 – The main features of the analyzer include:
  • Page 8 – Introduction; Front Panel Description; the function performed by the analyzer:; Set Alarm 1; Sets Alarm 1 Hi or Low, and the concentration
  • Page 9 – Rear Panel Description; Figure 1-2 Rear Panel
  • Page 10 – Power Connection
  • Page 11 – Operational Theory; The analyzer is composed of two subsystems:; Micro-Fuel Cell Sensor; The oxygen sensor used in the Model 3300PA is a Micro-Fuel Cell
  • Page 12 – Operational Theory
  • Page 15 – Electronics; The signal processing uses an Intel
  • Page 17 – Unpacking the Analyzer
  • Page 18 – Installation; Location and Mounting; Figure 3-1 Electrical Connectors for AC Control Unit
  • Page 19 – Primary Input Power: The power cord receptacle, fuse block and; input receptacle assembly.; Analog Outputs: There are three DC output signal connectors with; Alarm 1 and Alarm 2 can both be configured as either HI or LO. A HI
  • Page 20 – Figure 3-2: Contact ID for FAILSAFE Relay Operation; The specific descriptions for each type of alarm are as follows:; Sensor Fail; Gas Connections; assist in setting the flow of the gas.
  • Page 21 – (standard piping diagram for positive pressure service)
  • Page 22 – Figure 3-3: Piping Diagram for Vacuum Service Option; Installation Checklist
  • Page 23 – Operation; Once the analyzer has been mounted, the gas lines connected and the; Figure 4-1: Front Panel Controls and Indicators
  • Page 24 – Operation; Setting the Analysis Ranges
  • Page 25 – Setting the Alarm Setpoints
  • Page 27 – Selecting a Fixed Range or Autoranging; Preliminary—If not already done: Power up the Analyzer and
  • Page 28 – Supplementary Information; If, during the Span Procedure, you pressed the SPAN button by mis-; CAUTION: TET/AI considers the action of pressing the ALARM or
  • Page 29 – Remove Power to Unit before replacing the fuse.
  • Page 30 – Maintenance; Sensor Installation or Replacement; Ordering and Handling of Spare Sensors; To have a replacement cell available when it is needed, TBE/AI recom-
  • Page 31 – Disconnect the Power Source from the Unit.; Open Sensor Housing door on the front panel.
  • Page 32 – Remove the new Micro-Fuel Cell from its protective bag, being
  • Page 33 – Appendix; –10 V dc, negative ground; System Operating Temp:
  • Page 34 – Spare Parts List; DESCRIPTION; or your local representative.
  • Page 35 – Reference Drawing; Final Assembly (and interconnection diagram); Miscellaneous; The symbol: ~ is used on the rear panel of the model 3300PA to signify
Loading the manual

i

Teledyne Analytical Instruments

OPERATING INSTRUCTIONS

FOR

Model 3300PA

Percent Oxygen Analyzer

HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING
SYSTEM.

PERSONAL PROTECTIVE EQUIPMENT MAY BE REQUIRED WHEN SERVICING THIS SYSTEM.

HAZARDOUS VOLTAGES EXIST ON CERTAIN COMPONENTS INTERNALLY WHICH MAY PERSIST
FOR A TIME EVEN AFTER THE POWER IS TURNED OFF AND DISCONNECTED.

ONLY AUTHORIZED PERSONNEL SHOULD CONDUCT MAINTENANCE AND/OR SERVICING. BEFORE
CONDUCTING ANY MAINTENANCE OR SERVICING CONSULT WITH AUTHORIZED SUPERVISOR/
MANAGER.

DANGER

P/N M69127

08/06/99

ECO # 99-0323

SERIES 3300 PERCENT OXYGEN

SAMPLE

SPAN

Te ledy ne Analytical Ins tr um ents

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Copyright © 1999 Teledyne Analytical Instruments

ii Teledyne Analytical Instruments Copyright © 1999 Teledyne Analytical Instruments All Rights Reserved. No part of this manual may be reproduced, transmitted, tran- scribed, stored in a retrieval system, or translated into any other language or computerlanguage in whole or in part, in any form or b...

Page 3 - Contents; Introduction

iii Teledyne Analytical Instruments Contents Introduction 1.1 Overview ........................................................................ 1-11.2 Main Features of the Analyzer ....................................... 1-11.3 Front Panel Description ...................................................

Page 4 - Maintenance

iv Teledyne Analytical Instruments 4.4.1 Alarm 1 .................................................................. 4-3 4.4.2 Alarm 2 .................................................................. 4-3 4.4.3 Sensor Fail Alarm .................................................. 4-4 4.5 Selecting a ...