Teledyne 3000ZA - Manual

Teledyne 3000ZA

Teledyne 3000ZA – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
Page: / 81

Table of Contents:

  • Page 2 – Teledyne Analytical Instruments; ii; Copyright © 2003 Teledyne Analytical Instruments
  • Page 3 – iii; Specific Model Information; The instrument for which this manual was supplied may
  • Page 4 – iv; Important Notice
  • Page 5 – Safety Messages; Your safety and the safety of others is very important. We have; GENERAL WARNING/CAUTION; This warning is; Symbol
  • Page 6 – This manual provides information designed to guide you through
  • Page 7 – vii
  • Page 8 – Table of Contents
  • Page 9 – System
  • Page 10 – Fuse Replacement
  • Page 11 – List of Figures
  • Page 12 – xii; List of Tables; Table 3-3: Remote Calibration Connections
  • Page 13 – Introduction; Typical Applications
  • Page 14 – Model Designations
  • Page 15 – The standard 3000ZA is housed in a rugged metal case with all
  • Page 16 – Analyze
  • Page 17 – Standby Button
  • Page 18 – Note: If you require highly accurate Auto-Cal timing, use external
  • Page 20 – Operational Theory; Sensor
  • Page 21 – The sample system delivers gases to the ZrO
  • Page 22 – Zirconium Oxide Sensor Application Notes; Dust and oil should be filtered from the sample gas.; Electronics and Signal Processing
  • Page 23 – In the presence of oxygen the cell generates a current. A current to
  • Page 26 – Installation; Unpacking the Analyzer
  • Page 27 – All operator controls, except the flow control needle valve, are
  • Page 28 – Rear Panel Connections; Figure 3-3 shows the Model 3000ZA rear panel. There are ports for; Gas Connections
  • Page 29 – AWAY; CAUTION: OPERATING THE UNIT WITHOUT RESTRICTORS CAN; SAMPLE IN
  • Page 30 – If greater sample flow is required for improved response time,
  • Page 31 – The fuse block, at the right of the power cord; Figure 3-4 shows the pin layout of the Equipment Interface
  • Page 32 – Pin; The nine alarm-circuit connector pins connect to the
  • Page 33 – Digital Remote Cal Inputs:
  • Page 34 – Span; – Remote Zero; Remote Calibration Protocol:
  • Page 35 – When the CRC closes, remove the span command.; A serial digital input/output for local network protocol.
  • Page 36 – The voltage from these outputs is nominally 0 V for the OFF and
  • Page 37 – The digital signal output is a standard, full duplex RS-232 serial; Immediately starts an autospan.
  • Page 38 – Parity; Installing the Zirconium Oxide Sensor
  • Page 40 – Operation; Enter
  • Page 41 – Using the Data Entry and Function Buttons
  • Page 42 – Figure 4-1: Hierarchy of Available Functions; Ariel Narrow Bold; type style. Pushbutton names are printed in
  • Page 43 – Function
  • Page 45 – Setting up an Auto-Cal; Auto—Cal
  • Page 46 – Password Protection; PSWD
  • Page 47 – Changing the; Entering the Password; A A A A A
  • Page 49 – Note: If you log off the system using the logout function in the
  • Page 50 – More; Version Self—Test; Maintenance and Troubleshooting; Version
  • Page 51 – The Zero and Span Functions; A span gas with a known oxygen concentration in the range of
  • Page 52 – Zero; AUTO
  • Page 54 – Maintenance
  • Page 56 – FCAL
  • Page 57 – Alarms
  • Page 58 – Alarm; LO
  • Page 59 – Dft–; Range; Front Panel
  • Page 60 – Fixed Range Analysis
  • Page 61 – The Analyze Function; Escape; Voltage Signal
  • Page 62 – The analog output signal has a voltage which depends on the; In the event of loss of flow through the analyzer, if the
  • Page 64 – Routine Maintenance; Aside from normal cleaning and checking for leaks at the gas; Cell Replacement; The ZrO
  • Page 65 – Figure 5-2: Removing Fuse Block from Housing
  • Page 66 – System Self Diagnostic Test; Power; Analog; OK
  • Page 67 – Preamp; Major Internal Components; The zirconium sensor is accessed by unlatching and swinging open
  • Page 68 – Problem; Press
  • Page 70 – Appendix
  • Page 71 – Operating Temperature:
  • Page 72 – Part Number Description; TELEDYNE Analytical Instruments
  • Page 74 – A.5 Application Notes; APPLICATION NOTES ON RESTRICTORS,
  • Page 75 – The standard restrictor (BLUE DOT) is recommended for pressures
  • Page 76 – OPERATION WITHOUT A RESTRICTOR DEVICE:
  • Page 78 – Index
Loading the manual

Trace Oxygen Analyzer

Teledyne Analytical Instruments

i

OPERATING INSTRUCTIONS FOR

MODEL 3000ZA

Trace Oxygen Analyzer

DANGER

Toxic gases and or flammable liquids may be present in this monitoring system.

Personal protective equipment may be required when servicing this instrument.

Hazardous voltages exist on certain components internally which may persist
for a time even after the power is turned off and disconnected.

Only authorized personnel should conduct maintenance and/or servicing.
Before conducting any maintenance or servicing, consult with authorized
supervisor/manager.

P/N M75739

4/10/04

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Teledyne Analytical Instruments; ii; Copyright © 2003 Teledyne Analytical Instruments

3000ZA Teledyne Analytical Instruments ii Copyright © 2003 Teledyne Analytical Instruments All Rights Reserved. No part of this manual may be reproduced, transmitted, transcribed,stored in a retrieval system, or translated into any other language or computer language inwhole or in part, in any form ...

Page 3 - iii; Specific Model Information; The instrument for which this manual was supplied may

Trace Oxygen Analyzer Teledyne Analytical Instruments iii Specific Model Information The instrument for which this manual was supplied may incorporate one or more options not supplied in the standard instrument.Commonly available options are listed below, with check boxes. Anythat are incorporated i...

Page 4 - iv; Important Notice

3000ZA Teledyne Analytical Instruments iv Important Notice Model 3000ZA complies with all of the requirements of the Commonwealth of Europe (CE) for Radio Frequency Interference,Electromagnetic Interference (RFI/EMI), and Low Voltage Directive(LVD). The following International Symbols are used throu...

Other Teledyne Models

All Teledyne Other