Page 2 - Care and Maintenance; TABLE OF CONTENTS
2 Before Using the Monitor Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Operating the Device . . . . . . . . . . . . ....
Page 3 - INTRODUCTION; Fill in for future reference.; SAVE THESE INSTRUCTIONS; Before Using the Monitor
3 Thank you for purchasing the Omron ® Elite 7300IT IntelliSense ® Automatic Blood Pressure Monitor. INTRODUCTION Fill in for future reference. DATE PURCHASED: __________________ SERIAL NUMBER: ____________________ Staple your purchase receipt here Your new digital blood pressure monitor uses the os...
Page 4 - OPERATING THE DEVICE; The monitor is not intended to be a diagnostic device.; SAFETY INFORMATION
4 To assure the correct use of the product, basic safety measures shouldalways be followed including the warnings and cautions listed in thisinstruction manual. WARNING Indicates a potentially hazardous situationwhich, if not avoided, could result in death orserious injury. SAFETY SYMBOLS USED IN TH...
Page 6 - CARE AND MAINTENANCE; Do not submerge the device or any of the components in water.
CARE AND MAINTENANCE Do not subject the monitor to strong shocks, such as dropping the uniton the floor. Do not submerge the device or any of the components in water. Store the device and the components in a clean, safe location. Changes or modification not approved by Omron Healthcare will voidthe ...
Page 7 - BEFORE TAKING A MEASUREMENT
7 BEFORE TAKING A MEASUREMENT To ensure a reliable reading follow these recommendations: 1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 15 minutesbefore taking the measurement. 2. Stress raises blood pressure. Avoid t...
Page 8 - KNOW YOUR UNIT; Operating Instructions; Battery Compartment
8 KNOW YOUR UNIT Main Unit: Operating Instructions Battery Compartment Memory Button ( ) Display Date/Time SettingButton ( ) Air Jack Start/Stop Button USB Port
Page 9 - Air Tube
KNOW YOUR UNIT 9 Components: Air Tube Air Plug (Connects to Air Jack) Stylish Zipper Case Four “AAA” Alkaline Batteries Instruction Manual Ultra Premium Automatic Blood Pressure Monitor with Two Cuffs Model Elite 7300IT INSTRUCTION MANUAL ENGLISH ESP AÑOL Cuff Selection Guide The Omron Æ Elite 7300I...
Page 10 - UNIT DISPLAY; NOTES; • The backlight turns on when setting the date and time, setting
10 UNIT DISPLAY Movement Error Symbol Low Battery Indicator Deflation Symbol Heartbeat Symbol/Hypertension Indicator Irregular Heartbeat Symbol Average Value Symbol Memory Symbol Pulse Display Medication Reminder Alarm Symbol Date/Time Display Guest Symbol Systolic Blood Pressure Diastolic Blood Pre...
Page 11 - IRREGULAR HEARTBEAT SYMBOL; display with the measurement values.; MOVEMENT ERROR SYMBOL; The Movement Error Symbol; DISPLAY SYMBOLS
11 IRREGULAR HEARTBEAT SYMBOL ( ) When the monitor detects an irregular rhythm two or more times duringthe measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values. An irregular heartbeat rhythm is defined asa rhythm that is more than 25% slower or25% fa...
Page 12 - HEARTBEAT SYMBOL/HYPERTENSION INDICATOR; AVERAGE VALUE SYMBOL
HEARTBEAT SYMBOL/HYPERTENSION INDICATOR ( ) TAKING A MEASUREMENT The Heartbeat Symbol ( ) flashes on the display during the measurement. The Heartbeat Symbol ( ) flashes at every heartbeat. When the measurement is complete, the Heartbeat Symbol ( ) flashes on the display with your blood pressure and...
Page 13 - AHA Home Guideline for Upper Limit of Normal BP; Systolic Blood Pressure; WARNING; ) flashes on the display with your measurement
The American Heart Association recommends the following guideline forupper limit of normal for home blood pressure readings: AHA Home Guideline for Upper Limit of Normal BP Systolic Blood Pressure 135 mmHg Diastolic Blood Pressure 85 mmHg This is a general guideline because blood pressure depends on...
Page 14 - BATTERY INSTALLATION
1. Press the ▼ indicator on the battery cover and slide the cover off in the direction ofthe arrow. 2. Install 4 “AAA” size batteries so the + (positive) and – (negative) polaritiesmatch the polarities of the batterycompartment as indicated. 3. Replace the battery cover. BATTERY INSTALLATION 14 Batt...
Page 15 - • Turn the unit off before replacing the batteries. If the batteries; CAUTION; Low Battery Indicator
BATTERY REPLACEMENT When the Low Battery Indicator appears on the display screen, turn themonitor off and remove all the batteries. Replace with four new 1.5Valkaline batteries at the same time. WARNING If battery fluid should get in your eyes, immediately rinse with plentyof clean water. Contact a ...
Page 16 - TO START THE SETTING; The year flashes on the display.; SETTING THE DATE AND TIME
16 Set the monitor to the current date and time before taking a measurementfor the first time. If the date and time are not set correctly, themeasurement values stored in the memory and the average values maynot be correct. The Blood Pressure Monitor automatically stores up to 84 individualmeasureme...
Page 18 - SETTING THE MINUTE
18 4. SETTING THE DAY Press the Memory button ( ) to advance by increments of one day. Press the Date/Time Setting button ( ) to set the current day. The hour flashes on the display. 5. SETTING THE HOUR The time is set using AM or PM. Press the Memory button ( ) to advance by increments of one hour....
Page 19 - RESETTING THE DATE AND TIME; on
RESETTING THE DATE AND TIME If the date and time is incorrect and needs to be changed, always resetbefore taking the next measurement. To adjust the date or time after the initial setting: Start with the monitor in the off position. 1. Press and hold the Date/Time Setting button ( ). The Medication ...
Page 20 - SETTING THE MEDICATION REMINDER ALARM
WARNING Do not rely solely on the Medication Reminder function to takemedicines throughout the day. The date and time must be set to the current date and time before theMedication Reminder Alarm is set. The Medication Reminder Alarm isset to “off” at the time of purchase. The Medication Reminder Ala...
Page 23 - SETTING THE SECOND MEDICATION REMINDER ALARM; iii. Press the Memory button to set the; TO TURN THE MONITOR OFF; Press the START/STOP button to turn the monitor off.
5. SETTING THE SECOND MEDICATION REMINDER ALARM i. Press Memory button (M) to select ON.Press the DATE/TIME Setting button. ii. Press Memory button (M) to set the hour. Press the Date/Time Setting button. iii. Press the Memory button to set the minutes. Press the Date/Time Settingbutton. Refer to “R...
Page 24 - Make a loop with the Cuff Guide by; APPLYING THE ARM CUFF
CAUTION Read all of the information in the instruction manual and any otherliterature in the box before operating the unit. CAUTION This device is intended for use in measuring blood pressure and pulserate in the adult population. Do not use this device on infants orpersons who cannot express their ...
Page 25 - APPLYING THE CUFF ON THE LEFT ARM; Make sure the air plug is securely inserted into the Air Jack.
2. Remove clothing from your upper arm and position the Cuff Guide on yourupper arm. 3. Tighten the Cuff Guide around your arm. 4. The cut-out arrow on the Cuff Guide indicates the correct cuff size for yourarm circumference.Orange use the Standard Adult Cuff, Purple use the Large Adult Cuff. APPLYI...
Page 27 - APPLYING THE CUFF ON THE RIGHT ARM; • Be careful not to rest your arm on the air tube. This will
27 APPLYING THE ARM CUFF APPLYING THE CUFF ON THE RIGHT ARM When taking a measurement using the right arm, use the instructionbelow in place of Step 3 on page 26. Apply the cuff to your right upper arm so the arrow and the air tube runsalong the inside of your elbow. The bottom of the cuff should be...
Page 28 - TAKING A MEASUREMENT
1. Sit in a chair with your feet flat on the floor. Place your arm with the cuff on a table so the cuff is level with your heart. 2. Press the START/STOP button. All symbols appear on the display. The cuff starts to inflate automatically. As the cuff inflates, the monitorautomatically determines you...
Page 30 - USING THE GUEST MODE; Press and hold the START/STOP button for
The monitor stores measurement values for one user in the memory.The guest mode can be used to take a single measurement for anotheruser. USING THE GUEST MODE No measurement values are stored in the memory when the guest modeis selected. 1. Press and hold the START/STOP button for 3 seconds. The Gue...
Page 31 - AVERAGING FUNCTION; • If two sets of measurement values are stored in the memory; USING THE MEMORY FUNCTION
Every time you complete a measurement the monitor stores the bloodpressure and pulse rate in the memory. The monitor automatically stores up to 84 sets of measurement values(blood pressure and pulse rate). When 84 sets of measurement values arestored, the oldest record is deleted to save the most re...
Page 32 - TO DISPLAY THE MEASUREMENT VALUES; ) appears on the display when the average
TO DISPLAY THE MEASUREMENT VALUES 1. Press the Memory button ( ). The Average Symbol ( ) appears on the display when the average reading is shown. 2. Press the Memory button ( ) to display the most recent set of measurement values on the screen. The values are displayed from themost recent to the ol...
Page 33 - TO DELETE ALL VALUES STORED IN THE MEMORY; You cannot partially delete values stored in the memory.
TO DELETE ALL VALUES STORED IN THE MEMORY You cannot partially delete values stored in the memory. 1. Press the Memory button ( ) to turn the monitor on. 2. Press the Memory button ( ) again. While holding the Memorybutton ( ), press theStart/Stop button down forapproximately 5 seconds untilthe digi...
Page 34 - OMRON HEALTH MANAGEMENT SOFTWARE; This software is exclusive to Omron blood pressure monitors and; Refer to the enclosed Software Installation Guide for details.; USING THE SOFTWARE
OMRON HEALTH MANAGEMENT SOFTWARE Omron Health Management Software allows you to view, track and printdata about blood pressure measured by Omron blood pressure monitorsand pedometers with PC download. NOTE: This software is exclusive to Omron blood pressure monitors and pedometers with PC download. ...
Page 36 - Select the blood pressure
4. Click [Download Data] icon to import the data. 5. The Confirm dialog appears. Make sure your cable isconnected then click [Yes]. 6. Select the blood pressure monitor being used and click[OK]. 7. Start importing data. Click [Cancel] if you want tocancel. USING THE SOFTWARE 36
Page 38 - Do not forcefully bend; the arm cuff or air tube. Do not fold tightly.; Clean the monitor with a soft dry cloth.; Do not use any abrasive; Store the device and the components in a clean, safe location.; if the unit will not be used for three months or; CARE AND MAINTENANCE
38 To keep your digital blood pressure monitor in the best condition and to protect the unit from damage, follow the directions listed below: Store the monitor in the Stylish ZipperCase when not in use. Do not forcefully bend the arm cuff or air tube. Do not fold tightly. Clean the monitor with a so...
Page 40 - Batteries are worn; ERROR INDICATORS; ERROR INDICATORS AND TROUBLESHOOTING TIPS
Contact Consumer Support at800-634-4350. A malfunction hasoccurred. 40 SYMBOL CAUSE CORRECTION Remove the arm cuff. Refer to“Taking a Measurement”. Cuff over-inflated Take another measurement andremain still until themeasurement is complete. Monitor could notdetect pulse wave. Air plug is notconnect...
Page 41 - PROBLEM; No display appears on the unit.; TROUBLESHOOTING TIPS
41 ERROR INDICATORS AND TROUBLESHOOTING TIPS PROBLEM CAUSES AND SOLUTIONS No power. No display appears on the unit. Replace all four batteries with newones.Check the battery installation for proper placement of the battery polarities. Measurement values appeartoo high or too low. Blood pressure vari...
Page 42 - FCC STATEMENT
42 FCC STATEMENT NOTE: POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class Bdigital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmfulinterfere...
Page 43 - WARRANTY
WARRANTY 43 Your Omron ® Elite 7300IT IntelliSense ® Automatic Blood Pressure Monitor, excluding the arm cuffs and batteries, is warranted to be free from defects in materialsand workmanship appearing within 5 years from the date of purchase, when usedin accordance with the instructions provided wit...
Page 44 - SPECIFICATIONS
44 Model: Elite 7300IT Display: LCD Digital Display Measurement Range: Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min. Accuracy/Calibration: Pressure: ±3mmHg or 2% of readingPulse: ±5% of reading Inflation: Automatic by electric pump Deflation: Automatic rapid deflation pressure Rapid Air Release: Au...
Page 45 - These specifications are subject to change without notice.
Memory: Up to 84 measurement values Contents: Main Unit, Standard and Large Adult Cuffs, Instruction Manual, 4 “AAA” Alkaline batteries, CD-ROM, USB Cable, Stylish Zipper Case, Cuff Selection Guide, Warranty Card, Cuff Guide andSoftware Installation Guide UPC Code: 0 73796 73090 1 NOTE: These specif...
Page 47 - Modelo; MANUAL DE INSTRUCCIONES; ESP
Monitor de presión arterial automático Ultra Premium con dos brazaletes Modelo Elite 7300IT MANUAL DE INSTRUCCIONES ESP AÑOL
Page 48 - Cuidado y mantenimiento; CONTENIDO
E2 Antes de usar el monitor Introducción . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E3Información de seguridad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E4 Cómo operar el dispositivo . . . . . . . . . . . . . . ...
Page 49 - INTRODUCCIÓN; Completar para una referencia futura.; GUARDE ESTAS INSTRUCCIONES; Antes de usar el monitor
E3 Gracias por comprar el monitor de presión arterial automático de Omron ® Elite 7300IT IntelliSense ® . INTRODUCCIÓN Completar para una referencia futura. FECHA DE LA COMPRA: ______________ NÚMERO DE SERIE: __________________ Abroche aquí su comprobante de compra. Su nuevo monitor de presión arter...
Page 50 - ADVERTENCIA; PRECAUCIÓN; CÓMO OPERAR EL DISPOSITIVO; INFORMACIÓN DE SEGURIDAD
E4 Para asegurar el uso correcto del producto, siempre deberían seguirsemedidas de seguridad básicas incluyendo las advertencias yprecauciones enumeradas en el presente manual de instrucciones. ADVERTENCIA Indica una situación potencialmente peligrosaque, si no se evitara, podría dar como resultadol...
Page 51 - CÓMO OPERAR EL DISPOSITIVO (continuación)
CÓMO OPERAR EL DISPOSITIVO (continuación) Este dispositivo está diseñado para realizar tomas de presión arterial yritmo cardíaco en adultos. No utilice este dispositivo en niños opersonas que no pueden expresar sus intenciones. Opere el dispositivo sólo con el fin para el que fue diseñado. Noutilice...
Page 52 - CUIDADO Y MANTENIMIENTO; No sumerja el dispositivo ni ninguno de sus componentes en agua.
CUIDADO Y MANTENIMIENTO No someta el monitor a golpes fuertes, como por ejemplo, dejar caerla unidad al suelo. No sumerja el dispositivo ni ninguno de sus componentes en agua. Guarde el dispositivo y los componentes en un lugar limpio y seguro. Los cambios o las modificaciones que no hayan sido apro...
Page 53 - ANTES DE TOMAR UNA MEDICIÓN; El estrés eleva la presión arterial. Evite tomar mediciones en
E7 ANTES DE TOMAR UNA MEDICIÓN A fin de garantizar una lectura confiable, siga las recomendaciones quese enumeran a continuación: 1. Evite comer, tomar bebidas alcohólicas, fumar, hacer ejercicio y bañarse durante 30 minutos antes de tomar una medición. Descansedurante al menos 15 minutos antes de t...
Page 54 - CONOZCA LA UNIDAD; Instrucciones de funcionamiento; Pantalla
E8 CONOZCA LA UNIDAD Unidad principal: Instrucciones de funcionamiento Compartimiento de las pilas Botón de memoria ( ) Pantalla Botón deConfiguración de la fecha/hora ( ) Enchufe hembra del aire Botón START/STOP(Inicio/Detener) Puerto USB
Page 56 - PANTALLA DE LA UNIDAD; • La luz trasera se enciende cuando se configura la fecha y la
E10 PANTALLA DE LA UNIDAD Símbolo de error de movimiento Indicador de batería baja Símbolo de desinflado Símbolo de latido/Indicador de hipertensión Símbolo de latido irregular Símbolo de valor promedio Símbolo de memoria Pantalla de visualización del pulso Símbolo de Alarma del Recordatorio de Medi...
Page 57 - SÍMBOLO DE LATIDO IRREGULAR (; con los valores de medición.; SÍMBOLO DE ERROR DE MOVIMIENTO (; El Símbolo de error de movimiento; SÍMBOLOS DE LA PANTALLA
E11 SÍMBOLO DE LATIDO IRREGULAR ( ) Cuando el monitor detecta un ritmo irregular dos o más veces durante lamedición, aparecerá en la pantalla el Símbolo de latido irregular ( ) con los valores de medición. El latido irregular se define como un ritmoque es más del 25% más lento o más del25% más rápid...
Page 58 - SÍMBOLO DE LATIDO/INDICADOR DE HIPERTENSIÓN; SÍMBOLO DE VALOR PROMEDIO
SÍMBOLO DE LATIDO/INDICADOR DE HIPERTENSIÓN ( ) CÓMO TOMAR UNA MEDICIÓN El símbolo de latido parpadea ( ) en la pantalla durante la medición. El símbolo de latido ( ) parpadea ante cada latido del corazón. Una vez que se completa la medición, el Símbolo de latido ( ) parpadea en la pantalla junto co...
Page 59 - Presión arterial sistólica; Si el Símbolo de latido (
La Asociación Estadounidense del Corazón (AHA, por sus siglas eninglés) recomienda los siguientes valores como límite máximo de unalectura normal de presión arterial tomada en el hogar: Pautas de la AHA para la medición de la presión arterial normal máxima en el hogar Presión arterial sistólica 135 ...
Page 60 - COLOCACIÓN DE LAS PILAS
1. Presione el indicador ▼ que aparece en la cubierta del compartimiento de las pilas ydeslice la cubierta en la dirección queindica la flecha. 2. Coloque 4 pilas “AAA” de modo que las polaridades + (positiva) y – (negativa)concuerden con las polaridades que seindican en el compartimiento de las pil...
Page 61 - • Apague la unidad antes de cambiar las pilas. Si las pilas se; Indicador de batería baja
CAMBIO DE LA BATERÍA Cuando el Indicador de Batería Baja aparezca en la pantalla, apague elmonitor y retire todas las pilas. Coloque las cuatro pilas nuevas 1.5V almismo tiempo. ADVERTENCIA En caso de que el fluido de las pilas entre en contacto con los ojos,enjuague de inmediato con abundante agua ...
Page 62 - PARA INICIAR LA CONFIGURACIÓN; CONFIGURACIÓN DE LA FECHA Y HORA
E16 Configure el monitor con la fecha y hora actuales antes de tomar unamedición por primera vez. Si no se configuran la fecha y horacorrectamente, es posible que los valores de medición y los valorespromedio no se guarden correctamente en la memoria. El monitor de presión arterial guarda automática...
Page 63 - CONFIGURACIÓN DEL AÑO; para avanzar aumentando por años.; CONFIGURACIÓN DEL MES; para avanzar aumentando por meses.
CONFIGURACIÓN DE LA FECHA Y HORA 2. CONFIGURACIÓN DEL AÑO El año se puede configurar entre 2008 y 2030.Cuando la pantalla llega a 2030, vuelve a 2008. Presione el botón Memoria [Memory] ( ) para avanzar aumentando por años. Presione el botón de Configuración de lafecha/hora ( ) para configurar el añ...
Page 65 - RECONFIGURACIÓN DE LA FECHA Y HORA
RECONFIGURACIÓN DE LA FECHA Y HORA Si la fecha y hora son incorrectas y deben modificarse, reconfiguresiempre el dispositivo antes de realizar la próxima medición. Para ajustar la fecha y hora después de la configuración inicial: Comience con el monitor en la posición apagado. 1. Presione y mantenga...
Page 67 - ) para alternar entre; La hora parpadeará en la pantalla.; CONFIGURACIÓN DE LA ALARMA DE RECORDATORIO DE MEDICAMENTO
1. PARA INICIAR LA CONFIGURACIÓN Presione y mantenga presionado el botón deConfiguración de la fecha/hora ( ). El símbolo de Alarma de Recordatorio deMedicamento ( ) No.1 y la configuración oFF (apagado) aparecen en la pantalla. 2. CONFIGURACIÓN EN ON U OFF (Encendido/Apagado) Presione el botón Memo...
Page 68 - CONFIGURACIÓN DE LA HORA; La hora se configura en AM o PM.; CONFIGURACIÓN DE LOS MINUTOS; ) para avanzar aumentando; oFF
3. CONFIGURACIÓN DE LA HORA La hora se configura en AM o PM. Presione el botón Memoria [Memory] ( ) para avanzar aumentando por horas. Presione el botón de Configuración de lafecha/hora ( ) para configurar la hora. Los minutos parpadearán en la pantalla. 4. CONFIGURACIÓN DE LOS MINUTOS Presione el b...
Page 70 - Haga un bucle con la Guía del; COLOCACIÓN DEL BRAZALETE EN EL BRAZO
PRECAUCIÓN Lea toda la información del manual de instrucciones y cualquier otromaterial impreso incluido en la caja antes de comenzar a usar la unidad. PRECAUCIÓN Este dispositivo está diseñado para medir la presión arterial y el pulsoen pacientes adultos. Este dispositivo no debe utilizarse con beb...
Page 71 - COLOCACIÓN DEL BRAZALETE EN EL BRAZO IZQUIERDO; COLOCACIÓN DEL BRAZALETE PARA EL BRAZO; Naranja
2. Retire la ropa de la parte superior de su brazo y coloque allí la Guía del brazalete. 3. Ajuste la Guía del brazalete alrededor de su brazo. 4. La flecha recortada de la Guía del brazalete indica el tamaño correcto del brazalete parala circunferencia de su brazo.La naranja utiliza el brazalete es...
Page 73 - • Tenga cuidado de no apoyar el brazo sobre el tubo de aire.
E27 COLOCACIÓN DEL BRAZALETE PARA EL BRAZO COLOCACIÓN DEL BRAZALETE PARA EL BRAZO EN ELBRAZO DERECHO Cuando se toma una medición en el brazo derecho, use estasinstrucciones para el paso 3 de la página 26. Coloque el brazalete en la parte superior del brazo derecho de modo quela flecha y el tubo de a...
Page 77 - FUNCIÓN DE PROMEDIO; • Si se guardan dos conjuntos de valores de medición en la; USO DE LA FUNCIÓN MEMORIA
Cada vez que complete una medición, el monitor guarda la presiónarterial y el pulso en la memoria. El monitor almacena automáticamente hasta 84 valores de medición(presión arterial y pulso). Una vez almacenados 84 valores de mediciónen la memoria, el registro más antiguo se borrará para guardar los ...
Page 78 - PARA MOSTRAR LOS VALORES DE MEDICIÓN; El símbolo de promedio (
PARA MOSTRAR LOS VALORES DE MEDICIÓN 1. Presione el botón Memoria [Memory] ( ). El símbolo de promedio ( ) aparece en la pantalla cuando se muestra la lectura promedio. 2. Presione el botón Memoria [Memory] ( ) para mostrar el conjunto de valores de medición más reciente en la pantalla. Los valores ...
Page 80 - SOFTWARE PARA EL CUIDADO DE LA SALUD DE OMRON; Este software es exclusivo para los monitores de medición de; USO DEL SOFTWARE
SOFTWARE PARA EL CUIDADO DE LA SALUD DE OMRON El software para el cuidado de la salud de Omron le permitirá visualizar,procesar e imprimir información acerca de la presión arterial y de lascaminatas medidas con el monitor de presión arterial y pedómetro deOmron. NOTA: Este software es exclusivo para...
Page 81 - No permita que los objetos
USO DEL SOFTWARE E35 Utilice sólo el cable USB autorizado por Omron, Modelo HHX-CABLE-USB2, incluido con esta unidad. PRECAUCIÓN Use sólo las piezas y accesorios autorizados por Omron. Las piezas yaccesorios que no hayan sido aprobados para el uso con el dispositivopueden causar daños en la unidad. ...
Page 84 - CUIDADO Y MANTENIMIENTO; Cuidado y Mantenimiento
E38 Para mantener el monitor de presión arterial digital en las mejores condicionesy proteger la unidad de modo que no se dañe, siga estas instrucciones: Guarde el monitor en el eleganteestuche con cierre hermético cuando no lo esté utilizando. No doble el brazalete ni el tubo de aire por la fuerza....
Page 86 - INDICADORES DE ERROR Y RESOLUCIÓN DE PROBLEMAS
Contacte al Servicio de Atención alCliente llamando al 800-634-4350. Ha ocurrido undesperfecto técnico. E40 SÍMBOLO CAUSA CORRECCIÓN Retire el brazalete para el brazo.Consulte “Cómo tomar unamedición”. El brazalete estáinflado en exceso Tome otra medición y quédesequieto hasta que se complete lamedi...
Page 87 - PROBLEMA; No hay alimentación eléctrica.
E41 INDICADORES DE ERROR Y RESOLUCIÓN DE PROBLEMAS PROBLEMA CAUSAS Y SOLUCIONES No hay alimentación eléctrica. No aparece ningún símbolo enla pantalla de la unidad. Cambie las cuatro pilas por pilas nuevas.Verifique la colocación de las pilas para asegurarse de que las polaridades están correctament...
Page 88 - DECLARACIÓN DE FCC
E42 DECLARACIÓN DE FCC NOTA: POTENCIAL DE INTERFERENCIA DE RADIO/TELEVISÓN (para EE.UU. solamente) Este producto ha sido probado y cumple con los límites de un dispositivo digitalde Clase B, de acuerdo con la sección 15 de las normas de la FCC. Estos límites fueron diseñados para proporcionar una pr...
Page 89 - GARANTÍA
GARANTÍA E43 El monitor automático de presión arterial de Omron ® Elite 7300IT IntelliSense ® , salvo los brazaletes para el brazo y las pilas, está garantizado como libre de defectosmateriales y de mano de obra que se presenten dentro de los 5 años a partir de la fechade compra, si se lo usa de acu...
Page 90 - ESPECIFICACIONES
E44 Modelo: Elite 7300IT Pantalla: Pantalla digital LCD Rango de medición: Presión: 0 a 299 mmHg, Pulso: 40 a 180/min. Precisión/Calibración: Presión: ±3mmHg o 2% de lecturaPulso: ±5% de lectura Inflado: Automático por bomba eléctrica Desinflado: Presión automática de desinflado rápido Liberación rá...
Page 91 - Estas especificaciones están sujetas a modificaciones sin
Memoria: Hasta 84 valores de medición Contenido: Unidad principal, brazaletes estándar y grande paraadultos, manual de instrucciones, 4 pilas alcalinas“AAA”, CD-ROM, cable USB, elegante estuche concierre hermético, guía de selección del brazalete, tarjetade garantía, guía del brazalete y guía para l...