Page 2 - TABLE OF CONTENTS; Before using the Monitor; TABLE Of CONTENTS
2 TABLE OF CONTENTS Before using the Monitor Introduction ......................................................................................................... 3 Safety Information ................................................................................................ 4 Operating the De...
Page 3 - INTRODUCTION; Fill in for future reference.; SAVE THESE INSTRUCTIONS
3 INTRODUCTION Thank you for purchasing the OMRON ® BP710 IntelliSense ® Automatic Blood Pressure Monitor. Your new digital blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood’s movement through your brachial artery and conver...
Page 4 - SAfETY INfORMATION; SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL
4 SAfETY INfORMATION To assure the correct use of the product, basic safety measures should always be followed including the warnings and cautions listed in this instruction manual. SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL WARNING Indicates a potentially hazardous situation which, if not avoid...
Page 5 - CARE AND MAINTENANCE
5 Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit. Use only 1.5 V “AAA” alkaline batteries with this device. Do not use other types of batteries. This may damage the unit. CARE AND MAINTENANCE Do not subject the monitor ...
Page 6 - BEfORE TAKING A MEASUREMENT
6 BEfORE TAKING A MEASUREMENT To ensure a reliable reading follow these recommendations: 1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement. 2. Stress raises blood pressure. Avoid ...
Page 7 - KNOW YOUR UNIT; Standard Adult Arm Cuff
7 KNOW YOUR UNIT Main Unit: Components: Standard Adult Arm Cuff Instruction Manual Quick Start Guide Display Battery compartment Memory (M) button START/STOP button Air jack Air tube Air plug INSTRUCTION MANUAL Automatic Blood Pressure Monitor Model BP710 INTRODUCTION Thank you for purchasing the OM...
Page 8 - UNIT DISPLAY
8 UNIT DISPLAY Systolic blood pressure Diastolic blood pressure Irregular Heartbeat symbol Battery low indicator Deflation symbol Pulse display Heartbeat symbol Memory symbol (Displayed when viewing values stored in memory)
Page 9 - DISPLAY SYMBOLS; IRREGULAR HEARTBEAT SYMBOL (; TAKING A MEASUREMENT; USING THE MEMORY FUNCTION
9 DISPLAY SYMBOLS IRREGULAR HEARTBEAT SYMBOL ( ) When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values. An irregular heartbeat rhythm is defined as a rhythm that is more than 25...
Page 10 - AHA Home Guideline for Upper Limit of Normal BP; WARNING
10 DISPLAY SYMBOLS The American Heart Association recommends the following guideline for upper limit of normal for home blood pressure readings: AHA Home Guideline for Upper Limit of Normal BP Systolic Blood Pressure 135 mmHg Diastolic Blood Pressure 85 mmHg This is a general guideline because blood...
Page 11 - BATTERY INSTALLATION; CAUTION; BATTERY REPLACEMENT
11 BATTERY INSTALLATION CAUTION Use only 1.5V “AAA” alkaline batteries with this device. 1. Press the ▲ indicator on the battery cover and slide the cover off in the direction of the arrow. 2. Install 4 “AAA” size batteries so the + (positive) and - (negative) polarities match the polarities of the ...
Page 12 - APPLYING THE ARM CUff; Left Arm
12 APPLYING THE ARM CUff CAUTION Read all of the information in the instruction manual and any other literature in the box before operating the unit. CAUTION This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or perso...
Page 13 - APPLYING THE CUFF ON THE RIGHT ARM; Right Arm
13 APPLYING THE ARM CUff 4. Wrap the cuff firmly in place around your arm using the cloth fastening. APPLYING THE CUFF ON THE RIGHT ARM When taking a measurement using the right arm, use this instruction for Step 3. Apply the cuff to your right upper arm so the arrow and the air tube runs along the ...
Page 15 - SPECIAL CONDITIONS
15 TAKING A MEASUREMENT 5. Press the START/STOP button to turn the monitor off. NOTE: The monitor will automatically turn off after five minutes. SPECIAL CONDITIONS CAUTION Inflating to a higher pressure than necessary may result in bruising where the cuff is applied. If your systolic pressure is kn...
Page 16 - USING THE MEMORY fUNCTION; TO DELETE ALL THE VALUES STORED IN MEMORY
16 USING THE MEMORY fUNCTION Every time you complete a measurement the monitor stores the blood pressure and pulse rate in the memory. The monitor automatically stores up to 14 sets of measurement values (systolic pressure, diastolic pressure, and pulse rate). When 14 sets of measurement values are ...
Page 17 - Do not forcefully
17 CARE AND MAINTENANCE To keep your digital blood pressure monitor in the best condition and protect the unit from damage, follow the directions listed below: Do not forcefully bend the arm cuff or air tube. Do not fold tightly. Clean the monitor with a soft dry cloth. Do not use any abrasive or vo...
Page 18 - ERROR INDICATORS; SYMBOL
18 ERROR INDICATORS SYMBOL CAUSE CORRECTION Monitor could not detect pulse wave. Take another measurement and remain still until the measurement is complete. Cuff under-inflated. Cuff not applied correctly. Remove the arm cuff. Read “Taking a Measurement”. Wait 2-3 minutes. Take another measurement....
Page 19 - TROUBLESHOOTING TIPS; PROBLEM
19 TROUBLESHOOTING TIPS PROBLEM CAUSES AND SOLUTIONS No power. No display appears on the unit. Replace all four batteries with new ones. Check the battery installation for proper placement of the battery polarities. Measurement values appear too high or too low. Blood pressure varies constantly. Man...
Page 20 - fCC STATEMENT
20 fCC STATEMENT Note: POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only)This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules.These limits are designed to provide reasonable protection against harmful interfere...
Page 21 - LIMITED WARRANTIES
21 LIMITED WARRANTIES Your BP710 IntelliSense ® Automatic Blood Pressure Monitor, excluding the arm cuff, is warranted to be free from defects in materials and workmanship appearing within 2 years from the date of purchase, when used in accordance with the instructions provided with the monitor. The...
Page 22 - SPECIfICATIONS
22 SPECIfICATIONS Model: BP710 (HEM-7113-Z) Display: LCD Digital Display Measurement Range: Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min. Accuracy/Calibration: Pressure: ±3mmHg or 2% of reading Pulse: ±5% of reading Inflation: Automatic by electric pump Deflation: Automatic pressure release valve R...
Page 23 - NOTE: These specifications are subject to change without notice.
23 SPECIfICATIONS Memory: Up to 14 readings Contents: Main Unit, Standard Adult Arm Cuff, Instruction Manual, and Quick Start Guide Optional Accessories: Large Cuff 13" - 17" (320 mm - 420 mm) = Type B NOTE: These specifications are subject to change without notice.