Page 2 - TABLE OF CONTENTS; Before using the Monitor; TABLE Of CONTENTS
2 TABLE OF CONTENTS Before using the Monitor Introduction ......................................................................................................... 3 Safety Information ................................................................................................ 4 Operating the De...
Page 3 - INTROdUCTION; Fill in for future reference.; SAVE THESE INSTRUCTIONS
3 INTROdUCTION Thank you for purchasing the OMRON ® BP652 IntelliSense ® Automatic Wrist Blood Pressure Monitor. The monitor is compact and easy-to-use at home, at work, and during travel. Perfect for people who frequently monitor their own blood pressure. Your new digital blood pressure monitor use...
Page 4 - SAfETY INfORMATION; SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL
4 SAfETY INfORMATION To assure the correct use of the product, basic safety measures should always be followed including the warnings and cautions listed in this instruction manual. SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL WARNING Indicates a potentially hazardous situation which, if not avoid...
Page 5 - CARE AND MAINTENANCE
5 SAfETY INfORMATION Do not use a cellular phone near the device. It may result in an operational failure. Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit. Use only 1.5 V “AAA” alkaline batteries with this device. Do not...
Page 6 - BEfORE TAKING A MEASUREMENT
6 BEfORE TAKING A MEASUREMENT To ensure a reliable reading follow these recommendations: 1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement. 2. Stress raises blood pressure. Avoid ...
Page 7 - KNOW YOUR UNIT; AAA
7 KNOW YOUR UNIT Main Unit: Components: 2 “ AAA ” Alkaline Batteries Instruction Manual Quick Start Guide Date/Time setting ( ) button Display Wrist cuff Memory (MEM) buttonSTART/STOP button User ID selection switchSET button Battery compartment Date/Time setting ( ) button INTRODUCTION Thank you fo...
Page 8 - UNIT dISPLAY
8 UNIT dISPLAY Positioning indicator Diastolic blood pressure Irregular heartbeat symbol Memory symbol (Displayed when viewing values stored in memory)Average value symbol (Refer to “Using the Memory Function” .) Movement error symbol (Displayed if you move your body during the measurement)User ID s...
Page 9 - dISPLAY SYMBOLS; IRREGULAR HEARTBEAT SYMBOL (; Home Guideline for Upper Limit of Normal BP
9 dISPLAY SYMBOLS IRREGULAR HEARTBEAT SYMBOL ( ) When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values. An irregular heartbeat rhythm is defined as a rhythm that varies by less ...
Page 11 - BATTERY INSTALLATION; CAUTION
11 BATTERY INSTALLATION CAUTION Use only 1.5V “AAA” alkaline batteries with this device. 1. Press the hook on the bottom of the battery cover and lift the cover off in the direction of the arrow. 2. Install 2 “AAA” size batteries so the + (positive) and - (negative) polarities match the polarities o...
Page 12 - BATTERY REPLACEMENT; WARNING
12 BATTERY REPLACEMENT Low Battery Indicator When the Low Battery Indicator appears on the display, turn the monitor off and remove all the batteries. Replace with 2 new batteries at the same time. Long-life alkaline batteries are recommended. WARNING If battery fluid should get in your eyes, immedi...
Page 13 - SETTING THE dATE ANd TIME; TO START THE SETTING; SETTING THE MONTH
13 SETTING THE dATE ANd TIME Set the monitor to the current date and time before taking a measurement for the first time. 1. TO START THE SETTING Press the Date/Time Setting button ( ) to adjust the date and time. The year flashes on the display. 2. SETTING THE YEAR Press the Date/Time Setting butto...
Page 14 - SETTING THE MINUTE; TO TURN THE MONITOR OFF
14 4. SETTING THE DAY Press the Date/Time Setting button ( ) to advance by increments of one day. Press the Date/Time Setting button ( ) to set the current day. The hour flashes on the display. 5. SETTING THE HOUR The time is set using AM or PM. Press the Date/Time Setting button ( ) to advance by i...
Page 15 - SETTING THE AdVANCEd POSITIONING SENSOR (APS); SETTING THE POSITIONING INDICATOR
15 SETTING THE AdVANCEd POSITIONING SENSOR (APS) You can change the options for various settings on your monitor. Pressing the SET button to change a setting. Press the MEM button to select the options for that setting. After selecting a setting, press the START/STOP button to confirm the setting an...
Page 16 - SETTING FOR RIGHT OR LEFT WRIST MEASUREMENT; SETTING THE BUZZER
16 SETTING FOR RIGHT OR LEFT WRIST MEASUREMENT 1. While in the setting mode, press the SET button until the wrist symbol ( or ) appears on the display. NOTES: • The default setting is “ ”. • After you choose “oFF” for the Positioning indicator, the monitor skips this process. 2. Press the MEM button...
Page 17 - RESETTING TO THE DEFAULT SETTING
17 If the Positioning indicator is “on1” or “on2”: on1: The buzzer sounds only when the monitor is in proper position. on2: The buzzer sounds a series of two short blips if your wrist is too far away from the measuring position, and beeps when your wrist is in the proper position. oFF: The buzzer wi...
Page 18 - APPLYING THE WRIST CUff
18 CAUTION Read all of the information in the instruction manual and any other literature in the box before operating the unit. CAUTION This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express ...
Page 19 - APPLYING THE CUFF ON THE RIGHT WRIST
19 5. Fold the remaining part of the wrist cuff back out of the way. APPLYING THE CUFF ON THE RIGHT WRIST When taking a measurement using the right wrist position the cuff as shown in the illustration. Refer to “Setting for Right or Left Wrist for Measurement”. APPLYING THE WRIST CUff
Page 20 - TAKING A MEASUREMENT
20 The monitor is designed to take measurements and store the measurement values in memory for two people using USER ID A and USER ID B. The monitor can be used to take a single measurement using the GUEST mode are not stored in the memory. 1. Sit comfortably in a chair with your feet flat on the fl...
Page 22 - USING THE MEMORY fUNCTION; AVERAGING FUNCTION
22 USING THE MEMORY fUNCTION Every time you complete a measurement the monitor stores the blood pressure and pulse rate for each user (A and B) in the memory. The monitor automatically stores up to 100 sets of measurement values (blood pressure and pulse rate) for each user (A and B). When 100 sets ...
Page 23 - TO DELETE ALL VALUES STORED IN THE MEMORY
23 USING THE MEMORY fUNCTION NOTES: • The date and time are alternately displayed with the measurement values. • Press the MEM button repeatedly to display the next values. • Press and hold the MEM button to display the values faster. 3. Press the START/STOP button to turn the monitor off. TO DELETE...
Page 24 - CARE ANd MAINTENANCE; Do not forcefully
24 CARE ANd MAINTENANCE To keep your digital blood pressure monitor in the best condition and protect the unit from damage, follow the directions listed below: Do not forcefully bend the cuff. Do not fold tightly. Clean the monitor with a soft dry cloth. Do not use any abrasive or volatile cleaners....
Page 25 - ERROR INdICATORS; SYMBOL
25 ERROR INdICATORS SYMBOL CAUSE CORRECTION Monitor could not detect pulse wave. Take another measurement and remain still until the measurement is complete. Cuff under-inflated. Cuff not applied correctly. Remove the monitor from your wrist. Read “Taking a Measurement”. Wait 2-3 minutes. Take anoth...
Page 26 - TROUBLESHOOTING TIPS; PROBLEM
26 TROUBLESHOOTING TIPS PROBLEM CAUSES AND SOLUTIONS No power. No display appears on the unit. Replace both batteries with new ones at the same time. Check the battery installation for proper placement of the battery polarities. Measurement values appear too high or too low. Blood pressure varies co...
Page 27 - fCC STATEMENT
27 fCC STATEMENT Note: POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules.These limits are designed to provide reasonable protection against harmful interfer...
Page 28 - LIMITEd WARRANTY
28 Your BP652 IntelliSense ® Automatic Wrist Blood Pressure Monitor, excluding the wrist cuff and batteries, is warranted to be free from defects in materials and workmanship appearing within 5 years from the date of purchase, when used in accordance with the instructions provided with the monitor. ...
Page 29 - SPECIfICATIONS; NOTE: These specifications are subject to change without notice.
29 SPECIfICATIONS Model: BP652 (HEM-6052-Z) Display: LCD Digital Display Measurement Range: Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min. Accuracy/Calibration: Pressure: ±3mmHg or 2% of reading Pulse: ±5% of reading Inflation: Automatic by electric pump Deflation: Automatic pressure release valve R...