National Instruments NI TB-2708 - Manual

National Instruments NI TB-2708

National Instruments NI TB-2708 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – Caution; What You Need to Get Started; Cautions
  • Page 3 – not; Installation
  • Page 4 – DAQ Getting Started Guide; Signal Descriptions
  • Page 5 – S Series User
  • Page 6 – Measuring Floating Signals; resistor in parallel with a 0.1; Measuring Ground-Referenced Signals; S Series User Manual; Configuration; Floating Source
  • Page 7 – Cabling Options; Pin Number; Black
  • Page 9 – Specifications; Physical
  • Page 10 – Environment; The NI TB-2708 is intended for indoor use only.; Safety; Note; in the Certification column.; Waste Electrical and Electronic Equipment (WEEE); EU Customers; Where to Go for Support; you have access to everything from
  • Page 11 – and follow the calling
Loading the manual

INSTALLATION GUIDE

NI TB-2708

PXI Terminal Block for S Series Devices

This installation guide describes how to install and connect signals to the
NI TB-2708 terminal block for use with PXI-6115/6120 S Series devices.

Caution

The connectors of the TB-2708 are sensitive to electrostatic discharge (ESD). The

user should ground themselves and/or design watchdog timing into their application prior
to connecting or disconnecting signals.

Introduction

The TB-2708 is a terminal block assembly consisting of nine SMB
connectors and a 14-pin I/O connector. The terminal block assembly
connects directly to the front panel of National Instruments PXI-6115
and PXI-6120 devices, eliminating the need for an external cable.

Figure 1.

TB-2708 Device View

1

Access Door to Configuration Switches

2

14-Pin I/O Connector (Digital Signals)

3

SMB Connectors (Analog Signals)

AI 0

AI 1

AI 2

AI

3

AO

0

AO 1

AI

S

TAR

T

TRIG

AI

S

AMP

CLK

CTR 0

OUT

I

1

2

3

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Caution; What You Need to Get Started; Cautions

NI TB-2708 Installation Guide 2 ni.com The nine SMB connectors on the TB-2708 allow you to easily connect analog input and analog output signals to your National Instruments device. The 14-pin I/O connector located on the bottom of the TB-2708 allows access to digital signals. Caution The TB-2708 is...

Page 3 - not; Installation

© National Instruments Corporation 3 NI TB-2708 Installation Guide Do not substitute parts or modify equipment. Because of the danger of introducing additional hazards, do not install unauthorized parts or modify the device. Return the device to National Instruments for service and repair to ensure ...

Page 4 - DAQ Getting Started Guide; Signal Descriptions

NI TB-2708 Installation Guide 4 ni.com To connect the terminal block to the PXI module I/O connector, refer to Figure 2 as you complete the following steps: 1. Install the PXI module into the chassis and tighten the two module screws. You must install the PXI device before connecting the TB-2708. Re...

Other National Instruments Models

All National Instruments Other