Table of Contents:
- Page 2 – Vertical; Specification; Impedance and Coupling
- Page 3 – Voltage Levels; Accuracy
- Page 6 – Horizontal; Sample Clock
- Page 8 – Trigger
- Page 12 – TClk Specifications
- Page 13 – Waveform Specifications
- Page 15 – Software
- Page 16 – Environment
- Page 18 – Safety; CE Compliance
- Page 19 – Environmental Management; Waste Electrical and Electronic Equipment (WEEE); Physical; Front Panel Connectors; ⬉ᄤֵᙃѻક∵ᵻࠊᄣ⧚ࡲ⊩ ˄Ё; RoHS
- Page 20 – Dimensions and Weight; NI PXI-5114 Front Panel Indicators
- Page 22 – Where to Go for Support
NI PXI/PCI-5114 Specifications
8-Bit 250 MS/s Digitizer
This document lists the specifications for the NI PXI/PCI-5114 (NI 5114)
high-speed digitizer. Unless otherwise noted, these specifications are valid
for the following conditions:
•
All filter settings
•
All impedance selections
•
Sample clock set to 250 MS/s
Typical values are representative of an average unit operating at room
temperature. Specifications are subject to change without notice. For the
most recent NI 5114 specifications, visit
ni.com/manuals
.
To access the NI 5114 documentation, including the
NI High-Speed
Digitizers Getting Started Guide
, which contains functional descriptions
of the NI 5114 signals, navigate to
Start»All Programs»National
Instruments»NI-SCOPE»Documentation
.
Hot Surface
If the NI 5114 has been in use, it may exceed safe handling temperatures and
cause burns. Allow the NI 5114 to cool before removing it from the PXI chassis or PC.
Refer to the
section for operating temperatures of this device.
Contents
Analog Input (Channel 0 and Channel 1) ........................................ 2
Sample Clock ................................................................................... 6
Phase-Locked Loop (PLL) Reference Clock ................................... 7
CLK IN (Sample Clock and Reference Clock Input,
Front Panel Connector) ................................................................. 8
Reference (Stop) Trigger ................................................................. 8
TRIG (External Trigger, Front Panel Connector) ............................ 10
PFI 0 and PFI 1 (Programmable Function Interface,
AUX Front Panel Connectors) ............................................................. 11
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
NI PXI/PCI-5114 Specifications 2 ni.com Waveform Specifications ........................................................................13Calibration ...............................................................................................14Power ..................................................
© National Instruments Corporation 3 NI PXI/PCI-5114 Specifications Voltage Levels Full Scale (FS) Input Range and Programmable Vertical Offset 50 Ω 1 M Ω — Range (V pk-pk ) Vertical Offset Range (V) Range (V pk-pk ) Vertical Offset Range (V) 0.04 ±0.8 0.04 ±0.8 0.1 ±0.8 0.1 ±0.8 0.2 ±0.8 0.2 ±0.8 0...
NI PXI/PCI-5114 Specifications 6 ni.com Horizontal Sample Clock Specification Value Comments Sources Internal, Onboard Clock (internal VCXO)* External, CLK IN (front panel SMB connector) * Internal Sample Clock is locked to the Reference Clock or derived from the onboard VCXO Onboard Clock (Internal...