National Instruments NI TB-2706 - Manual

National Instruments NI TB-2706

National Instruments NI TB-2706 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – Safety Information; Cautions
  • Page 3 – Connecting the Signals; TB-2706 Parts Locator Diagram; S Series User Manual
  • Page 4 – Pinout Label for M Series
  • Page 5 – Installing the Terminal Block; Connecting the TB-2706 to an M Series or PXI-6143 Device; Caution; not
  • Page 6 – Specifications; The TB-2706 is not designed for input voltages greater than 42 V; Physical; Screw terminals; Environment; certification; Certification column.; Electromagnetic Compatibility; EN 61326 EMC requirements Minimum Immunity; Note
  • Page 7 – CE Compliance; compliance information. To obtain the DoC for this product, visit; Waste Electrical and Electronic Equipment (WEEE); EU Customers; At the end of their life cycle, all products; Where to Go for Support; support; United States, contact your local branch office:
Loading the manual

INSTALLATION GUIDE

NI TB-2706

PXI/PXIe Terminal Block for M Series and NI 6143 Devices

This installation guide describes how to install and connect signals to the NI TB-2706 terminal block
for use with PXI/PXIe M Series, NI PXI-6143, and other PXI/PXIe devices with a 68-pin VHDCI
connector.

Contents

Introduction.......................................................................................................................................... 1
What You Need to Get Started ............................................................................................................ 1
Safety Information ............................................................................................................................... 2
Connecting the Signals ........................................................................................................................ 3
Installing the Terminal Block .............................................................................................................. 5
Specifications ....................................................................................................................................... 6
Where to Go for Support ..................................................................................................................... 7

Introduction

The TB-2706 is a terminal block assembly consisting of a printed circuit board, 70 screw terminals, and
a metal enclosure with strain relief hardware. The terminal block assembly connects directly to the front
panel of National Instruments PXI-622

x

, PXI-625

x

, PXIe-625

x

, PXI-628

x

, and PXI-6143 devices,

eliminating the need for an external cable.

The TB-2706 allows you to easily connect analog input, analog output, counter/timer, and digital I/O
signals to your National Instruments device. The 70 screw terminals allow access to every pin on the
connector, plus two shield screw terminals for use with a shielded cable. For M Series devices with
two connectors, this terminal block allows access to every pin on Connector 0, plus two shield screw
terminals for use with a shielded cable, but makes Connector 1 inaccessible.

Caution

The TB-2706 is not designed for input voltages greater than 42 V

pk

/60 VDC, even if you

install a voltage divider that reduces the voltage to within the input range of the DAQ device. Input
voltages greater than 42 V

pk

/60 VDC can damage the TB-2706, any device connected to it, and the

host computer. Overvoltage also can cause an electric shock hazard for the operator. National
Instruments is

not

liable for damage or injury resulting from such misuse.

What You Need to Get Started

You need the following to set up and use your terminal block:

NI TB-2706 Terminal Block Assembly

NI TB-2706 Installation Guide

NI PXI/PXIe M Series device, NI PXI-6143, or other PXI/PXIe device with a 68-pin VHDCI
connector

M Series User Manual

,

S Series User Manual

, or other PXI/PXIe DAQ device documentation

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Safety Information; Cautions

NI TB-2706 Installation Guide 2 ni.com ❑ 0.10 in. slotted screwdriver ❑ Pinout label for M Series (adhered to cover of TB-2706) or pinout list for NI PXI-6143 ❑ Number 1 Phillips screwdriver ❑ 26–16 AWG wire ❑ Wire cutters ❑ Wire insulation stripper Safety Information Cautions Do not operate the dev...

Page 3 - Connecting the Signals; TB-2706 Parts Locator Diagram; S Series User Manual

© National Instruments Corporation 3 NI TB-2706 Installation Guide Connecting the Signals Refer to Figure 1 as you complete the following steps to connect signals to your terminal block. Figure 1. TB-2706 Parts Locator Diagram 1. Remove the terminal block cover by unscrewing the top cover screw usin...

Page 4 - Pinout Label for M Series

NI TB-2706 Installation Guide 4 ni.com Figure 2. Pinout Label for M Series Figure 3. Pinout for PXI-6143 2. Loosen or remove the strain-relief bar by loosening the two strain-relief screws with the Phillips-head screwdriver. 3. Use wire cutters and wire insulation strippers to strip no more than 7 m...

Other National Instruments Models

All National Instruments Other