National Instruments NI PXI/PCI-5114 - Manual

National Instruments NI PXI/PCI-5114

National Instruments NI PXI/PCI-5114 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 2 – Vertical; Specification; Impedance and Coupling
  • Page 3 – Voltage Levels; Accuracy
  • Page 4 – Bandwidth and Transient Response
  • Page 6 – Horizontal; Sample Clock
  • Page 8 – Trigger
  • Page 12 – TClk Specifications
  • Page 13 – Waveform Specifications
  • Page 15 – Software
  • Page 16 – Environment
  • Page 18 – EU Customers
  • Page 19 – Physical
  • Page 20 – Where to Go for Support
Loading the manual

NI PXI/PCI-5114 Specifications

8-Bit 250 MS/s Digitizer

Unless otherwise noted, the following conditions were used for each
specification:

All filter settings

All impedance selections

Sample clock set to 250 MS/s

Typical values are representative of an average unit operating at room
temperature. Specifications are subject to change without notice. For the
most recent NI 5114 specifications, visit

ni.com/manuals

.

To access the NI 5114 documentation, including the

NI High-Speed

Digitizers Getting Started Guide

, which contains functional descriptions of

the NI 5114 signals, navigate to

Start»Programs»National Instruments»

NI-SCOPE»Documentation

.

Hot Surface

If the NI 5114 has been in use, it may exceed safe handling temperatures and

cause burns. Allow the NI 5114 to cool before removing it from the PXI chassis.

Contents

Vertical .................................................................................................... 2

Analog Input (Channel 0 and Channel 1) ........................................ 2

Horizontal................................................................................................ 6

Sample Clock ................................................................................... 6
Phase-Locked Loop (PLL) Reference Clock ................................... 7
CLK IN (Sample Clock and Reference Clock Input,

Front Panel Connector) ................................................................. 8

Trigger ..................................................................................................... 8

Reference (Stop) Trigger ................................................................. 8
TRIG (External Trigger, Front Panel Connector) ............................ 10

PFI 0 and PFI 1 (Programmable Function Interface,

AUX Front Panel Connectors) ............................................................. 10

TClk Specifications ................................................................................. 12
Waveform Specifications ........................................................................ 13
Calibration............................................................................................... 14

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Vertical; Specification; Impedance and Coupling

NI PXI/PCI-5114 Specifications 2 ni.com Power .......................................................................................................14Software ...................................................................................................15Environment ..............................

Page 3 - Voltage Levels; Accuracy

© National Instruments Corporation 3 NI PXI/PCI-5114 Specifications Voltage Levels Full Scale (FS) Input Range and Programmable Vertical Offset 50 Ω 1 M Ω — Range (V pk-pk ) Vertical Offset Range (V) Range (V pk-pk ) Vertical Offset Range (V) 0.04 ±0.8 0.04 ±0.8 0.1 ±0.8 0.1 ±0.8 0.2 ±0.8 0.2 ±0.8 0...

Page 4 - Bandwidth and Transient Response

NI PXI/PCI-5114 Specifications 4 ni.com Figure 1. NI 5114 Frequency Response (Typical) Bandwidth and Transient Response Bandwidth (–3 dB) Range (V pk-pk ) Bandwidth Rise/Fall Time, Typical — All ranges except 0.04 125 MHz 2.8 ns 0.04 100 MHz 3.5 ns Bandwidth Limit Filter 20 MHz Noise Filter — AC Cou...

Other National Instruments Models