Leica SP2600- Manual

Leica SP2600

Leica SP2600– Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
Page: / 51

Table of Contents:

  • Page 3 – Leica SP2600 – Ultramilling attachment; NOTE
  • Page 4 – Table of contents
  • Page 5 – Leica SP 2600 – Ultramilling attachment; Important information
  • Page 7 – Important information; Information on this instruction manual; Instrument type; only to the instrument type indicated on the title page.; Working with this instruction manual; SP2600 ultramilling attachment.; instruction manual must be supplemented by additional appropri-
  • Page 8 – Safety; Safety regulations; with the Leica SM2500 sliding microtome!
  • Page 9 – The instrument is equipped with the following safety devices:; Plexiglass protective cover; • The miller is equipped with a protective cover made of plexiglass (; no matter whether the spindle is rotating or not.; Important note on the safety devices built in by the manufacturer:
  • Page 10 – Safety instructions - general; Safety instructions; Safety instructions - transport and installation
  • Page 13 – Ultramilling attachment; tained in the Leica SM2500 instruction manual.
  • Page 14 – Installation
  • Page 15 – Site requirements
  • Page 16 – Installing the Leica SP2600 ultramilling attachment
  • Page 17 – Connecting the vacuum cleaner; Milling dust is extracted by a vacuum cleaner, through a nozzle (; Installing vacuum cleaners rated at 230 V/ 50 Hz / max. power draw 4 A; Installing other vacuum cleaners:; the rear of the ultramilling attachment.
  • Page 18 – Installing additional accessories; • Connect the foot switch.; The foot switch must be connected - otherwise the instrument will
  • Page 19 – Overview of chapter 5 ‘Operation’; sure to read the following instruction manuals:; stages
  • Page 20 – calibrating device; Preparatory steps
  • Page 21 – Adjusting the miller; can no longer be moved.
  • Page 22 – Adjustment along the z-axis
  • Page 24 – Adjustment along the y-axis
  • Page 25 – Adjusting the finishing millers in the; • Carry out preparatory steps as per chapter 5.2,; Twisted or deformed springs for the; • Insert spring and finishing miller as described; When the finishing miller is inserted
  • Page 26 – Adjusting the finishing miller; justed in the miller holder along three different; Adjustment along the x-axis; • Carry out steps 1 - 4 as described on page 22
  • Page 29 – Specimen holder systems - how to combine individual components
  • Page 30 – Operation
  • Page 31 – the base plates; Clamping the vacuum stages in the base plate
  • Page 32 – placing specimens onto the vacuum; Connecting the vacuum pump
  • Page 33 – Placing specimens onto vacuum stage for 30 -
  • Page 34 – Preparatory steps prior to the milling procedure; For a detailed description of all control elements located on the; • Select manual mode of operation; MAN; • Move the milling spindle to the upper limit position (button (; the miller holders to the milling spindle!
  • Page 35 – manual) or - if you need to mill a vacuum table prior to first use - see
  • Page 36 – • Select automatic mode of operation ‘; AUTO’; • Select STOP or PHOTO position (buttons (; Individual parameter settings depend on specimen material and
  • Page 37 – Recommended milling thickness settings for pre-milling; • 10 μm - keep milling until surface is completely level.; Recommended sledge speed settings for pre-milling; • Return stroke: any speed; Recommended rotational speed of miller for pre-milling; • Select ‘continuous’ mode of operation.; Starting the milling procedure; • Switch on the vacuum cleaner (via button (
  • Page 38 – Pre-milling procedure
  • Page 39 – Ending the pre-milling procedure; p. 34 - instruction manual Leica SM2500) the miller continues to
  • Page 40 – Finishing milling; to attaching the miller holders to the milling spindle!; men surface as described for the pre-miller on page 35.; AUTO; ’ and set the; Recommended milling thickness settings for finishing milling; Do not exceed a milling thickness setting of 5 μm with the follow-
  • Page 41 – Recommended sledge speed settings for finishing milling; Recommended rotational speed of miller for finishing milling
  • Page 42 – Perspective view of the finishing milling procedure; Finishing milling procedure; )) while the specimen sledge passes underneath the miller in the di-
  • Page 43 – Ending the finishing milling procedure; Switching the instrument off (switching off the control unit)
  • Page 44 – Troubleshooting; chapter 6, page 64 of the Leica SM2 500 instruction manual .
  • Page 45 – Cleaning, disinfection and maintenance; Cleaning and disinfection; Cleaning; the detergents listed above.; Disinfection; pose of as per the regulations applicable.
  • Page 46 – Only authorized service technicians may access the internal com-; • Carry out the maintenance steps to be done by the user as per the in-
  • Page 47 – Replacing the light bulb in the calibration device
  • Page 48 – Miller holders and millers; Miller holder; Holder for pre- and finishing miller; Finishing miller; finishing miller; Base plates for specimen holders and vacuum stage adapters; • Specimen clamp 44 x 58 mm,; Vacuum stage adapters
  • Page 49 – Vacuum stages and matching lids / perforated specimen holders; • Vacuum stage for Leica SP2600 - basic body for lids 30 - 50 mm
  • Page 50 – Additional accessories; Vacuum cleaner and vacuum cleaner accessories; • Vacuum cleaner ‘Fakir S20’, with connection hose; Illumination; • Halogen spotlight illumination; Overview - accessories
  • Page 51 – Warranty and service
Loading the manual

Leica SP2600

Ultramilling attachment

Supplementary instruction manual Leica SP2600

To be used only in conjunction

with instruction manual Leica SM2500 .

V1.2 English – 07/2002

Always keep this manual near the instrument.

Read carefully prior to operating the instrument.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Leica SP2600

Summary

Page 3 - Leica SP2600 – Ultramilling attachment; NOTE

3 Leica SP2600 – Ultramilling attachment The information, numerical data, notes and value judgments contained in this manual represent the current state of scientific knowledge and state- of-the-art technology as we understand it follow- ing thorough investigation in this field. We are under no obli...

Page 4 - Table of contents

4 Supplementary instruction manual V 1.2 – 07/2002 Table of contents 1. Important information ................................................................................................................ 6 1.1 Symbols in the text and their meaning ....................................................

Page 5 - Leica SP 2600 – Ultramilling attachment; Important information

5 Leica SP 2600 – Ultramilling attachment Important information 6. Troubleshooting ....................................................................................................................... 44 7. Cleaning, disinfection and maintenance .......................................................

Other Leica Models