Table of Contents:

  • Page 2 – Contents
  • Page 3 – Intended Use; diagnostic use; gene via fluorescence; Required training; Summary and Explanation; Background; in vitro
  • Page 4 – Clinical Concordance Summary Leica BOND-MAX System; in situ
  • Page 5 – Leica BOND Enzyme; Contains Enzyme Diluent.; Directions For Use
  • Page 6 – Warnings and Precautions; For professional users only.; Procedure; A. Reagents required but not supplied; • Standard solvents used in fluorescence; B. Equipment required but not supplied; – Excitation Peak at 559nm,
  • Page 7 – automated; D. BOND Enzyme Pretreatment; and that a minimum volume of 900 μL be used per run.; E. Default Staining Protocol; recommended default staining protocol shown in Table 2 below.; Protocol Type; immunohistochemical or
  • Page 8 – 990 μL of Leica BOND Enzyme Diluent.
  • Page 9 – Signal Assessment and Enumeration
  • Page 10 – Recommended Method for LSI HER2 to CEP17 Ratio Determination; To determine the LSI HER2 to CEP17 ratio, use the following method:; additional 20 nuclei and recalculate the ratio.; Results should be reported as follows:
  • Page 11 – Leica HER2 FISH System - 30 Test Interpretation Guide
  • Page 12 – Leica HER2 FISH System - 30 Test Score Sheet; 0 Nuclei Signal Count
  • Page 13 – Quality Control; Use of Control Slides; section. The criteria for slide quality must be satisfied; Limitations; A. General Limitations
  • Page 14 – a qualified pathologist.; B. Product Specific Limitations; use of any other type of fixative may invalidate the assay.; Clinical Concordance of HER2 FISH System - 30 Test to Abbott; negative staining agreement.
  • Page 15 – PathVysion
  • Page 16 – Abbott Molecular PathVysion HER-2 DNA Probe Kit
  • Page 17 – Precision Testing – Leica BOND-MAX System; A. Within Run Precision Study; expression within a single run on a single instrument.; B. Within Instrument Precision Study
  • Page 18 – range of HER2 expression to be tested between lots.; Precision Testing – Leica BOND-III System; G. Within Run Precision Study; H. Within Instrument Precision Study
  • Page 19 – Assay Robustness; temperature and humidity.
  • Page 20 – denaturation time is recommended.
  • Page 21 – Troubleshooting
  • Page 22 – Problem; Department or Distributor for assistance.
  • Page 23 – References; fluorescence in situ hybridization.
  • Page 24 – Symbol Identification; Batch Code; Catalog number; Manufacturer; SN; Serial Number
Loading the manual

Page 1 of 24

English

Leica Biosystems Leica HER2 FISH System - 30 Test Instructions for Use TA9217 EN-CE-Rev_D 08/04/2013

Leica HER2 FISH System - 30 Test

Instructions For Use

For use on Leica Biosystems’ BOND-MAX and BOND-III System.

TA9217 is a fluorescence

in situ

hybridization product designed to stain 30 tests (30 slides

stained with LSI HER2/CEP17 Dual Probe).

Leica Biosystems Newcastle Ltd

Balliol Business Park West

Benton Lane

Newcastle Upon Tyne NE12 8EW

United Kingdom

(

+44 191 215 4242

Leica Biosystems Canada

71 Four Valley Drive

Concord, Ontario L4K 4V8

Canada

(

+1 800 248 0123

Leica Biosystems Inc

1700 Leider Lane

Buffalo Grove IL 60089

USA

(

+1 800 248 0123

Leica Biosystems Melbourne

Pty Ltd

495 Blackburn Road

Mt Waverly VIC 3149

Australia

(

+61 2 8870 3500

IVD

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Contents

English Page 2 of 24 English Leica Biosystems Leica HER2 FISH System - 30 Test Instructions for Use TA9217 EN-CE-Rev_D 08/04/2013 Contents Intended Use .......................................................................................................................................................

Page 3 - Intended Use; diagnostic use; gene via fluorescence; Required training; Summary and Explanation; Background; in vitro

Page 3 of 24 English Leica Biosystems Leica HER2 FISH System - 30 Test Instructions for Use TA9217 EN-CE-Rev_D 08/04/2013 English Intended Use For in vitro diagnostic use The Leica HER2 FISH System - 30 Test is designed to detect amplification of the HER2/neu gene via fluorescence in situ hybridizat...

Page 4 - Clinical Concordance Summary Leica BOND-MAX System; in situ

English Page 4 of 24 English Leica Biosystems Leica HER2 FISH System - 30 Test Instructions for Use TA9217 EN-CE-Rev_D 08/04/2013 The characteristic morphology of the tissue and the spatial distribution of oncogene copies in individual uncultured primary breast carcinomas are retained. Aberrations i...