Honeywell 1104 - Installation Manual
A user manual for the Honeywell HE120A/B by-pass humidifiers covers essential topics like installation safety, ductwork setup, and assembly procedures. The guide emphasizes proper placement to prevent hazards such as electrocution or freezing water, while also detailing electrical wiring and operational checks–including humidity control calibration–to ensure reliable performance after maintenance.
Table of Contents:
- Page 1 – Humidifier Installation and Duct Preparation
- Page 2 – Humidifier Component Assembly
- Page 3 – Wiring and Operational Checkout Procedure
INSTALLATION INSTRUCTIONS
69-1104—3
TE
MPLATE
TE
MP
LA
TE
TEMPLATE
HE120A,B
By-Pass Drum Humidifier
WARNING
Electrocution and Chemical Hazard.
Can cause death or blindness.
Do not cut or drill into any air conditioning line or electrical
accessory.
CAUTION
Freezing Water Hazard.
Can result in water damage to property.
Locate the humidifier where the ambient temperature is
between 32°F and 180°F (0°C and 93°C).
IMPORTANT
Template must be level before marking location.
1.
Determine the best location for the humidifier and draw a
level line on the duct. See Fig. 1.
2.
Tape this template in position and trace around it.
3.
Remove the template and carefully cut the rectangular open-
ing.
4.
Position the humidifier housing (see Fig. 2) over the hole (be
sure it is level) and mark the five mounting holes.
Fig. 1. Typical humidifier installation locations.
M12248D
HORIZONT
AL
DOWN
FLO
LOWBOY
HIGHBOY
HUMIDIFIER
BYPASS
COLLAR
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
About this manual
- Brand
- Honeywell
- Model
- 1104
- Document type
- Installation Manual
- Language(s)
- English
- Pages
- 3
- File size
- 252.1 KB
- Format
Other Manuals for Honeywell 1104
Summary
Installation instructions for the By-Pass Drum Humidifier, safety warnings regarding electrocution and freezing water, and guidance for modifying air ducts for proper installation.
Step-by-step procedures for assembling humidifier components, including the drum assembly, water pan, tubing connections, saddle valve installation, and water level adjustment.
Instructions for wiring the humidifier, verification procedures after startup or maintenance, electrical shock hazards warnings, and steps for adjusting water levels and verifying pad rotation.