Table of Contents:

  • Page 2 – SPECIFICATIONS; Processer
  • Page 3 – APPROVALS; Signal Processor Mounting; WARNING; Signal Processor Power
  • Page 6 – Viewing Head Connector and Wiring
  • Page 7 – Cable Preparation
  • Page 8 – Protecting the Viewing Head Cable; Viewing Head Mounting Block
  • Page 9 – Vibration; ACCESSORIES; Cable and Connectors - S70X/S80X Viewing Heads
  • Page 10 – Fiber Optic System Compatibility -; OPERATION; IR Detector; Filter Selection for IR Viewing Head; UV Detector
  • Page 11 – Adjustment of VH Sighting and Gain; NOTE: Adjustment to the viewing head parameters; Orificing; Front Panel LED Indicators and Display; • Two digit display; Push Button Functions; • RELAY ON SETPOINT button:
  • Page 12 – • LOAD FACTORY DEFAULTS button:; Manual Setup of Setpoints; Relay On Setpoint
  • Page 13 – Setting FFRT (Flame Failure Response; Automatic Setup of Setpoints
  • Page 14 – Panel Lock; MODBUS COMMUNICATION; Communication Setting
  • Page 15 – Modbus RTU Function Supported; Register
  • Page 16 – Fig. 7. Typical Communication Wiring and Recommended Addressing.
  • Page 17 – TROUBLESHOOTING; Lockout or Faulty VH Indication; MAINTENANCE
  • Page 21 – Mounting Examples
  • Page 23 – Fig. 17. Opposed Fired Viewing Head Sighting
  • Page 33 – SAFETY MANUAL: 700 SIGNAL PROCESSOR; Safety Function of the 700
  • Page 34 – Proof Test Interval; on the proof test interval for 700AC.; on the proof test interval for 700DC.
  • Page 35 – 00AC or 700DC Signal Processor Proof Test Procedure; Equipment; Product Decommissioning
  • Page 36 – Product Declaration
  • Page 37 – S70X and S80X Viewing Head Proof; S70X and S80X Viewing Head Proof Test Procedure
  • Page 40 – Automation and Control Solutions
Loading the manual

USER MANUAL

Put Bar Code Here

66-2069-02

Honeywell Model 700/800 Signal

Processor and Viewing Head

APPLICATION

The Honeywell Model 700ACSP and Model 700DCSP signal

processors are single-channel, fail safe, flame monitoring

systems when used In conjunction with the S70X/S80X

viewing heads. They offer easy setup, excellent discrimination,

and high reliability.

FEATURES

Viewing heads are interchangeable between the two signal

processor models. Any viewing head in the two families will

work with any of the signal processors.

Two signal processor models are available:

• Model 700ACSP Universal 85-265 VAC powered, plus

24VDC backup.

• Model 700DCSP 22-26VDC powered, plus 24VDC

backup.

The two Model 700 signal processors are similar, with 12

push-buttons, a two-digit numeric display, and four LED status

indicators for operator interface. The only difference between

the two is that one accepts AC power and the other accepts

DC power. Both models also accept 24VDC backup power.

Most of the signal processor connections are made through

Phoenix plug-in connectors. Communication connections are

made through modular phone jacks located at the top of the

signal processors (Fig. 8).

Both signal processor models mount on a standard 35 mm

DIN rail. They snap into place and may be released from the

rail using a flat screwdriver.

There are two types of viewing heads—IR/flicker-sensitive and

UV-sensitive—with various features offered resulting in ten

different models. See Table 1 on page 2 for details.

The S702 and S706 viewing head housings are larger in

diameter than the S80X series, are made of aluminum, and

are secured with over-center latches to their mounting blocks

(Fig. 9). In contrast, the S802 and S806 viewing head

housings are smaller in diameter and are made of stainless

steel (Fig. 10). An 800 series viewing head is secured in its

mounting block by a friction twist-lock.

The IR/flicker sensitive viewing heads have a high-pass filter

that passes flicker frequencies above 33 Hz. Some models

have a built-in high pass filter that only passes frequencies

above 155 Hz. The high frequency filter models are identified

by adding “HF” to the model number. The UV models respond

to the level of UV radiation—not UV flicker—so there is no

filter option.

Contents

Application .......................................................................

1

Features ...........................................................................

1

Specifications ...................................................................

2

Approvals .........................................................................

3

Installation ........................................................................

3

Operation ......................................................................... 10

Modbus Communication .................................................. 14

Troubleshooting ................................................................ 17

Maintenance .................................................................... 17

Safety Manual: 700 Signal Processor .............................. 33

Safety Manual: S70X & 80X Viewing Head ..................... 36

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SPECIFICATIONS; Processer

HONEYWELL MODEL 700/800 SIGNAL PROCESSOR AND VIEWING HEAD 66-2069—02 2 1. All models include Electronic self-check. 2. Flicker Frequency filter settings available for IR sensor models. 3. Gain Selection available through Signal Processor. The viewing heads, the viewing head connector, and the cable ...

Page 3 - APPROVALS; Signal Processor Mounting; WARNING; Signal Processor Power

HONEYWELL MODEL 700/800 SIGNAL PROCESSOR AND VIEWING HEAD 3 66-2069—02 APPROVALS S70X/S80X Viewing Heads (Connector series and Pipe fit series [PF]) CSA for CLASS I, DIV 2, GROUPS A, B, C, D & T4A FM 7610/NEMA 4X and CLASS 1, DIV 2, GROUPS A, B, C, D & T4A* SIL 3 “Fit for Use” IECEx CSA 10.0...

Page 6 - Viewing Head Connector and Wiring

HONEYWELL MODEL 700/800 SIGNAL PROCESSOR AND VIEWING HEAD 66-2069—02 6 Viewing Head Connector and Wiring Viewing heads are wired to the appropriate terminals located on bottom of the 700ACSP, 700DCSP, P531 or P532 signal processors. The terminals are listed functionally in Table 2. Connectors and ca...