P R O C E S S E Q U I P M E N T C ATA L O G

u p d a t e d 2 / 1 5

P R O C E S S E Q U I P M E N T C ATA L O G

Husky 3300 Plastic Pumps

Air-Operated Double Diaphragm

u p d a t e d 2 / 1 5

Husky 3300 Plastic Pumps

Polypropylene

Maximum fluid working pressure

100 psi (7.0 bar, 0.7 MPa)

Maximum free flow delivery*
Standard diaphragms at 100 psi (7.0 bar, 0.7 MPa)
Overmolded diaphragms at 100 psi (7.0 bar, 0.7 MPa)

280 gpm (1,059 lpm)
260 gpm (984 lpm)

Maximum pump speed*
Standard diaphragms at 100 psi (7.0 bar, 0.7 MPa)
Overmolded diaphragms at 100 psi (7.0 bar, 0.7 MPa)

97 cpm
130 cpm

Maximum suction lift *

(varies widely based on ball/seat selection and wear, operating

speed, material properties, and other variables)

8 ft (2.4 m) dry

Maximum size pumpable solids

0.5 in (13 mm)

Noise (dBa)***
Sound Power at 50 psi (3.4 bar) and 50 cpm
Sound Power at 120 psi (8.3 bar) and full flow
Sound Pressure at 50 psi (3.4 bar) and 50 cpm
Sound Pressure at 120 psi (8.3 bar) and full flow

92 dBa
99 dBa
86 dBa
93 dBa

Maximum air consumption

275 scfm (7.8 m

3

/min.)

Air pressure operating range

20 to 100 psi

(1.4 to 7.0 bar, 0.14 to 0.7 MPa)

Air inlet size

3/4 npt(f)

Fluid inlet/outlet

3 in (76.2 mm) ANSI/DIN flange

Weight

200 lb (91 kg)

Instruction manual

3A0410

Repair/parts manual

3A0411

* Maximum values with water as media at ambient temperature. Water level is approximately 3 feet above pump inlet.

** Startup pressures and displacement per cycle may vary based on suction condition, discharge head, air pressure, and fluid type.

*** Sound power measured per ISO-9614-2. Sound pressure was tested 3.28 ft (1 m) from equipment.

Technical Specifications

Performance Charts

FLUID FLOW

(Pump tested in water with inlet submerged)

Approx. Cycles per Minute

FLUID OUTLET PRESSURE

psi (bar

, MP

a)

AIR CONSUMPTION

scfm (m

3

/min)

gpm

(lpm)

50

(189)

125

(8.6, 0.86)

100

(7, 0.69)

75

(5.2, 0.52)

50

(3.4, 0.34)

25

(1.7, 0.17)

75

(2.1)

225

(6.4)

150

(4.2)

300

(8.5)

375

(10.6)

0

100

(379)

150

(568)

200

(757)

250

(946)

17.2

34.5

51.7

69.0

86.2

300

(1136)

0

Husky 3300 Performance

AIR PRESSURE

LEGEND

= at 125 psi (8.3 bar, 0.83 MPa)

Air Consumption

= at 100 psi (7 bar, 0.7 MPa)

Fluid Pressure

= at 70 psi (4.8 bar, 0.48 MPa)

A
B
C

= at 40 psi (2.8 bar, 0.28 MPa)

D

A

B

C

D

D

A

B

C

FLUID FLOW

(Pump tested in water with inlet submerged)

Approx. Cycles per Minute

FLUID OUTLET PRESSURE

psi (bar

, MP

a)

AIR CONSUMPTION

scfm (m

3

/min)

gpm

(lpm)

50

(189)

125

(8.6, 0.86)

100

(7, 0.69)

75

(5.2, 0.52)

50

(3.4, 0.34)

25

(1.7, 0.17)

75

(2.1)

225

(6.4)

150

(4.2)

300

(8.5)

375

(10.6)

0

100

(379)

150

(568)

200

(757)

250

(946)

17.2

34.5

51.7

69.0

86.2

300

(1136)

0

Husky 3300 Performance

AIR PRESSURE

LEGEND

= at 125 psi (8.3 bar, 0.83 MPa)

Air Consumption

= at 100 psi (7 bar, 0.7 MPa)

Fluid Pressure

= at 70 psi (4.8 bar, 0.48 MPa)

A
B
C

= at 40 psi (2.8 bar, 0.28 MPa)

D

A

B

C

D

D

A

B

C

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Graco Models

All Graco Other