Husky 515 Plastic Pumps
Air-Operated Double Diaphragm
P R O C E S S E Q U I P M E N T C ATA L O G
Popular Models
P R O C E S S E Q U I P M E N T C ATA L O G
Performance Charts
Technical Specifications
Husky 515 Plastic Pumps
Acetal
Polypropylene
PVDF
Maximum fluid working pressure
100 psi (7 bar, 0.7 MPa)
100 psi (7 bar, 0.7 MPa)
100 psi (7 bar, 0.7 MPa)
Maximum free flow delivery*
15 gpm (57 lpm)
15 gpm (57 lpm)
15 gpm (57 lpm)
Maximum pump speed
400 cpm
400 cpm
400 cpm
Displacement per cycle**
0.04 gallon (0.15 liter)
0.04 gallon (0.15 liter)
0.04 gallon (0.15 liter)
Maximum suction lift ***
15 ft (4.5 m) dry
15 ft (4.5 m) dry
15 ft (4.5 m) dry
Maximum size pumpable solids
0.09 in (2.5 mm)
0.09 in (2.5 mm)
0.09 in (2.5 mm)
Maximum ambient operating temperature†
180°F (82°C)
150°F (66°C)
180°F (82°C)
Maximum diaphragm operating temperature†
Refer to page 5
Refer to page 5
Refer to page 5
Typical sound level at 70 psi
(4.9 bar, 0.49 MPa) air @ 125 cpm
74 dBa
74 dBa
74 dBa
Maximum air consumption
28 scfm (0.672 m3/min)
28 scfm (0.672 m3/min)
28 scfm (0.672 m3/min)
Air pressure operating range
30 to 100 psi
(2.1 to 7 bar, 0.21 to 0.7 MPa)
30 to 100 psi
(2.1 to 7 bar, 0.21 to 0.7 MPa)
30 to 100 psi
(2.1 to 7 bar, 0.21 to 0.7 MPa)
Air inlet size
1/4 npt(f)
1/4 npt(f)
1/4 npt(f)
Air exhaust port size
3/8 npt(f)
3/8 npt(f)
3/8 npt(f)
Fluid inlet & outlet size****
1/2 npt(f) or bspt(f)
1/2 npt(f) or bspt(f)
1/2 npt(f) or bspt(f)
Weight
7.8 lb (3.5 kg)
6.5 lb (2.9 kg)
8.5 lb (3.9 kg)
Wetted parts
(in addition to ball, seat and diaphragm materials–
which may vary by pump)
Groundable Acetal, PTFE, SST
Polypropylene, PTFE, SST
PVDF, PTFE
Instruction manual
308981
308981
308981
* Flow rates are with muffler and do not vary based on diaphragm material.
** Displacement per cycle may vary based on suction condition, discharge head, air pressure and fluid type
*** Duckbill suction lift 11 ft (3.3 m)
**** Hybrid thread allows for either 1/4 npt or 1/4 bspt fitting
† Actual pump performance may be affected by prolonged usage at temperature.
FLUID FLOW
(Pump tested in water with inlet submerged
FLUID OUTLET PRESSURE
psi (bar
, MP
a)
AIR CONSUMPTION
scfm (m
3
/min)
gpm
(lpm)
80
(5.5, 0.55)
100
(7, 0.7)
60
(4.1, 0.41)
40
(2.8, 0.28)
20
(1.4, 0.14)
6
(0.17)
12
(0.37)
18
(0.50)
24
(0.67)
30
(0.84)
0
4
(15.2)
8
(30)
12
(45.42)
16
(60.56)
0
Husky 515 Performance
AIR PRESSURE
LEGEND
= at 100 psi (7 bar, 0.7 MPa)
Air Consumption
= at 70 psi (4.8 bar, 0.48 MPa)
Fluid Pressure
= at 40 psi (2.8 bar, 0.28 MPa)
A
B
C
= at 20 psi (1.4 bar, 0.14 MPa)
D
A
B
C
D
D
C
B
A
u p d a t e d 2 / 1 5
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.