Graco Husky 307- User Manual
Graco Husky 307– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
P R O C E S S E Q U I P M E N T C ATA L O G
Husky 307 Plastic Pumps
Air-Operated Double Diaphragm
Technical Specifications
Husky 307 Plastic Pumps
Acetal
Polypropylene
Maximum fluid working pressure
100 psi (7 bar, 0.7 MPa)
100 psi (7 bar, 0.7 MPa)
Maximum free flow delivery*
7.0 gpm (26.5 lpm)
7.0 gpm (26.5 lpm)
Maximum pump speed
330 cpm
330 cpm
Displacement per cycle**
0.02 gallon (0.076 liter)
0.02 gallon (0.076 liter)
Maximum suction lift (D31255)
12 ft (3.7 m) dry
12 ft (3.7 m) dry
Maximum size pumpable solids
0.06 in (1.5 mm)
0.06 in (1.5 mm)
Maximum ambient operating temperature***
180°F (65.5°C)
150°F (65.5°C)
Maximum diaphragm operating temperature***
Refer to page 5
Refer to page 5
Typical sound level at 50 psi
(3.5 bar, 0.35 MPa) air @ 50 cpm
75 dBa
75 dBa
Maximum air consumption
6 scfm (0.17 m3/min)
6 scfm (0.17 m3/min)
Air pressure operating range
20 to 100 psi
(1.4 to 8.4 bar, 0.14 to 0.84 MPa)
20 to 100 psi
(1.4 to 8.4 bar, 0.14 to 0.84 MPa)
Air inlet size
1/4 npt(f) or bspt(f)
1/4 npt(f) or bspt(f)
Fluid inlet & outlet size****
3/8 npt(f)
3/8 npt(f)
Weight
5.2 lb (2.4 kg)
4.75 lb (2.2 kg)
Wetted parts (in addition to ball, seat and
diaphragm materials–which may vary by pump)
Acetal with Stainless
Steel fibers, PTFE
Polypropylene, PTFE
Instruction manual
308553
308553
*Flow rates are with muffler and do not vary based on diaphragm material
**Displacement per cycle may vary based on suction condition, discharge head, air pressure and fluid type
***Actual pump performance may be affected by prolonged usage at temperature
Performance Chart
FLUID FLOW
(Pump tested in water with inlet submerged
FLUID OUTLET PRESSURE
psi (bar
, MP
a)
AIR CONSUMPTION
scfm (m
3
/min
gpm
(lpm)
1
(3.8)
100
(7, 0.7)
120
(8.4, 0.84)
80
(5.5, 0.55)
60
(4.1, 0.41)
40
(2.8, 0.28)
20
(1.4, 0.14)
1
(0.028)
2
(0.057)
3
(0.085)
4
(0.11)
5
(0.14)
6
(0.17)
0
2
(7.6)
3
(11.4)
4
(15.2)
5
(19.0)
6
(22.7)
8
(30.0)
7
(26.5)
0
C
Husky 307 Performance
AIR PRESSURE
LEGEND
= at 100 psi (7 bar, 0.7 MPa)
Air Consumption
= at 70 psi (4.8 bar, 0.48 MPa)
Fluid Pressure
= at 40 psi (2.8 bar, 0.28 MPa)
A
B
C
= at 20 psi (1.4 bar, 0.14 MPa)
D
A
B
C
D
A
B
D
u p d a t e d 2 / 1 5
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.