Page 3 - IMPORTANT SAFETY INFORMATION; CAUTION; Note
i IMPORTANT SAFETY INFORMATION Important safety messages are provided throughout this manual for the purpose of avoiding personal injury or instrument damage. Please read these messages carefully. Each safety message is associated with a safety alert symbol and placed throughout this manual and insi...
Page 4 - CONSIGNES DE SÉCURITÉ; MISE EN GARDE
ii CONSIGNES DE SÉCURITÉ Des consignes de sécurité importantes sont fournies tout au long du présent manuel dans le but d’éviter des blessures corporelles ou d’endommager les instruments. 1tée par un pictogramme d’alerte de sécurité; ces pictogrammes se retrouvent dans ce manuel et à l’intérieur des...
Page 5 - ABOUT THIS MANUAL; Rev
iii ABOUT THIS MANUAL This addendum is to be used in conjunction with the T200 Operation Manual, PN 06858 . REVISION HISTORY This section provides information regarding changes to this manual. 2011 December 07, Model T265 Addendum, Rev DCN Description of Changes B 6324 Specs update: Zero Noise, LDL,...
Page 7 - TABLE OF CONTENTS; LIST OF FIGURES
v TABLE OF CONTENTS IMPORTANT SAFETY INFORMATION ....................................................................................................................... I ABOUT THIS MANUAL ..................................................................................................................
Page 11 - CERTIFICATIONS
9 2. SPECIFICATIONS, APPROVALS, & CERTIFICATIONS Table 2-1 presents the specifications for the Model T265 analyzer. This is followed by EPA and Safety and Emissions Compliance information. 07337B DCN6324
Page 13 - DESIGNATION; APPROVALS AND CERTIFICATIONS
Model T265 Chemiluminescence Ozone Analyzer Addendum to Model T200 Manual Specifications, Approvals, & Certifications 11 2.1 EPA DESIGNATION Teledyne API’s Model T265 Chemiluminescence Ozone Analyzer received EPA approval for Designation EQOA-0611-199. The designation will be considered valid wh...
Page 15 - ATTENTION
13 3. GETTING STARTED This section addresses the procedures for unpacking the instrument and inspecting for damage, and introduces the instrument layout, then presents the procedures for getting started: making electrical and pneumatic connections, and conducting an initial calibration check. Please...
Page 16 - Remove the set screw located in the top, center of the front panel.
Getting Started Model T265 Chemiluminescence Ozone Analyzer Addendum to Model T200 Manual 14 CAUTION Remove dust plugs from pneumatic fittings on the rear panel of the analyzer, prior to applying power to the analyzer. Note It is recommended that you store shipping containers/materials for future us...
Page 17 - LAYOUT
Model T265 Chemiluminescence Ozone Analyzer Addendum to Model T200 Manual Getting Started 15 3.2 INSTRUMENT LAYOUT Instrument layout includes front panel and display, rear panel connectors, and internal chassis layout. 3.2.1 Front Panel Figure 3-1 illustrates the front panel of the Model T265 analyz...
Page 20 - CONNECTIONS AND SETUP; Electrical and Pneumatic Connections; Connect the power cord to the correct line voltage.; WARNING
Getting Started Model T265 Chemiluminescence Ozone Analyzer Addendum to Model T200 Manual 18 3.3 CONNECTIONS AND SETUP This section presents connection information for setting up the instrument to operate. 3.3.1 Electrical and Pneumatic Connections 1. Refer to Figure 3-2 for the rear panel electrica...
Page 22 - STARTUP, FUNCTIONAL CHECKS, AND INITIAL CALIBRATION
Getting Started Model T265 Chemiluminescence Ozone Analyzer Addendum to Model T200 Manual 20 STARTUP, FUNCTIONAL CHECKS, AND INITIAL CALIBRATION 3.4.1 Startup 1. Turn on the instrument by pressing the on/off rocker switch on the front panel. The display should immediately light, showing the computer...
Page 23 - Performing a zero/span calibration
Model T265 Chemiluminescence Ozone Analyzer Addendum to Model T200 Manual Getting Started 21 Setting the range and inputting the expected ozone span gas concentration Performing a zero/span calibration Running a calibration quality check Part 1 - Set the range, then enter the expected ozone sp...
Page 25 - SCHEDULE; “Ozone cleanser” does not apply.; MAINTENANCE ITEMS SPECIFIC TO THE MODEL T265
23 4. MAINTENANCE 4.1 MAINTENANCE SCHEDULE CAUTION The operations outlined in this section are to be performed by qualified maintenance personnel only. Please refer to the Instrument Maintenance section of the Model T200 manual for maintenance items and their interval schedules. Exceptions: “Ozone...
Page 27 - PRINCIPLES OF OPERATION; hv
25 5. PRINCIPLES OF OPERATION The Teledyne API Model T265 analyzer is designed to measure the concentration of ozone using the chemiluminescence reaction below. The signal comes from the light emitted by the gas phase reaction of nitric oxide (NO) and ozone (O 3 ) as follows: 2 * 2 3 O NO O NO ...
Page 29 - APPENDIX A: Models T265 and 265E Menu Trees
A-1 APPENDIX A: Models T265 and 265E Menu Trees The following menu trees in this appendix show the structure of the Sample menu and the Setup submenu. For additional details refer to Appendix A of the Model T200 operation manual. 07337B DCN6324
Page 33 - APPENDIX B - Spare Parts
APPENDIX B - Spare Parts Note Use of replacement parts other than those supplied by Teledyne Advanced Pollution Instrumentation (TAPI) may result in non-compliance with European standard EN 61010-1. Note Due to the dynamic nature of part numbers, please refer to the TAPI Website at
Page 35 - T265 Spare Parts List
T265 Spare Parts List (Reference: 07388 06/01/2011, 15:53) PARTNUMBER DESCRIPTION 000940600 CD, ORIFICE, .010 BROWN 000941800 CD, ORIFICE, .001, RED/BLK 001330000 SLEEVE, 303 SS (UNPLATED) (KB) 002160000 ASSY, SCRUBBER, M200A/AH/M100AH, PUMPACK 002270100 AKIT, GASKETS, WINDOW, (12 GASKETS = 1) 00273...
Page 40 - Appendix C; Warranty/Repair Questionnaire
Appendix C Warranty/Repair Questionnaire M265E and T265 (P/N 074990000 Rev A, DCN# 6167) TELEDYNE API CUSTOMER SERVICE EMAIL: [email protected] PHONE: (858) 657-9800 TOLL FREE: (800) 324-5190 FAX: (858) 657-9816 2. WHAT ARE THE RCELL & SAMPLE PRESSURES WITH THE SAMPLE INLET ON REA...
Page 41 - APPENDIX D – Wire List and Electronic Schematics
APPENDIX D – Wire List and Electronic Schematics 07337B DCN6324 D-1