Page 2 - ENGLISH; Technical information; CONTENTS
ENGLISH Bed scale 7711 2 Inputs in Setting mode p 15 Settings in Setting mode p 15 Settings in "Program Settings" menu p 15 Settings in "Terminal" menu p 15 5. Functions p 17 Power-on zeroing p 17 Manual zeroing p 17 x10 (times 10) display p 17 Weighing and taring p 17 Weighing with ...
Page 3 - ALLGEM EINE INFORMATIONEN
3 Thank you for choosing this Soehnle Professional pro-duct. All the features of this product were designed to the state of the art and are optimised for simple and straightforward use. If you have any queries or exper-ience any problems with your appliance not addressed in the operating manual, ple...
Page 4 - The manufacturer shall; The following disinfectants are permitted:
ENGLISH Bed scale 7711 4 ■ Safety instructions Before putting the appliance into use, please read with care the information given in the Operating Instructions. They contain important in-structions for installation, intended use and mainte-nance of the appliance. The manufacturer shall not be liable...
Page 5 - Disposal; Note
5 ■ Disposal According to the present state of the art the appliance contains no special environ-mentally harmful substances. This product is not to be treated as regular house hold waste, but should be handed in to an electrical/elec-tronic equipment recycling centre. You can obtain further details...
Page 7 - PUTTING INTO OPERATION; Installing the scale elements
7 2. PUTTING INTO OPERATION ■ Installing the scale elements The indicator's placement must allow for a simple disconnection from the power supply.Insert rechargeable batteries in all four weighing devices. When the batteries are fitted, the weighing devices start to send and attempt to set up a radi...
Page 8 - Radio link; OFF display; Charging the batteries; Digital indicator is off or in standby mode
ENGLISH Bed scale 7711 8 ■ Radio link The Bluetooth radio link operates over a max. radius of 5m if there is no partition wall between the weig-hing devices and the digital indicator. After short inter-ruptions (e.g. to replace a battery or caused by the loss of battery contact due to shocks), the l...
Page 9 - Display of link state:
9 Display of link state: Press Info key + 1. The following appears in the indicator display: Charge run time: A battery charge is sufficient for approx. 12 hrs con-tinuous duty. When the scale is switched off for most of the time (90% OFF), the batteries may remain in the weighing devices for up to ...
Page 10 - Keypad for input and control
ENGLISH Bed scale 7711 10 ■ Keypad for input and control KEYPAD: To enter nume-rical values or alphabetic characters (alphanumeric keypad) ORG key: Calls up Organisation Data INFO key: e.g. electro-nic nameplate contai-ning reference data C key: Deletes the last numeral or character F key: function ...
Page 11 - Alphanumeric input; Types of input box; Alphanumeric fields:
11 ■ Alphanumeric input It is possible to make alphanumeric inputs with the combined numeric and alphabetic character keypad. Types of input box • Display fields, read only• Display/writing fields with numeric input option• Display/writing fields with alphanumeric input option Input procedureNumeric...
Page 12 - Indicator display
ENGLISH Bed scale 7711 12 ■ Indicator display The display shows a number of different views de-pending on the situation. It is divided into display panes. Additional display It displays BMI, Gross, Net, etc. If required, it can be switched on with the F key according to the program settings. Icon ba...
Page 13 - Keypad in Setting mode
13 4. SETTING MODE ■ Keypad in Setting mode ORG key: Exits the Setting mode C key: Clears the last numeral/ character F key: Moves the marking arrow up the list or moves the cursor to the left T key (TARE key): Moves the marking arrow down the list or moves the cursor to the right ZEROING key: Retur...
Page 14 - Overview of menu navigation; Program settings
ENGLISH Bed scale 7711 14 ■ Overview of menu navigation The following setting options are available: Program settings Terminal Scales Data Processing Service General Weighing + taring Hold mode (p 20) Fixed tare value (p 17) Clear fixed tare value (p 19) Auto standby timePlausibility check sensor (p...
Page 15 - Version
15 ■ Calling up Setting mode Switch the appliance on. After the power-on routine, the appliance starts the last activated application program automatically. To call up Setting mode first press ENTER and then the F key simultaneously. You are now in the Setting mode selection menu. ■ Inputs in Settin...
Page 16 - Organisation data
ENGLISH Bed scale 7711 16 To accept, press ENTER for 3 seconds. Keytone Select "off" or "on". Confir-mation tone when a key is pressed. Factory setting: "off" Validation tone Select "off" or "on" Valida-tion tone when a function is executed. factory setting: &...
Page 17 - Display view; Weighing with measured tare; Determine and tare a bed weight without patient.
17 ■ Power-on zeroing During the power-on procedure, the weight values sent by the weighing devices are zeroed until they are less than 50% of the max. weighing range. This tares the empty bed and the weight display goes to zero. ■ Manual zeroing Manual zeroing corrects minor devia-tions from zero, ...
Page 18 - Weighing with manually; Showing the value in the tare memory; Weighing with stored tare values; Each memory location has a:
ENGLISH Bed scale 7711 18 ■ Weighing with manually entered tare If the patient is already on the bed and the bed weight is known, then this can be tared by manual input. Enter the known bed weight (tare weight) using the KEYPAD. The input appears in the display with the current weight unit. Press th...
Page 20 - Clearing a tare value; Provisional tare/dialysis function; Setting and using the operating mode
ENGLISH Bed scale 7711 20 • Confirm the message "General" by pressing ENTER.• Press the TARE key to browse to "Fixed tare va- lues" and accept by pressing ENTER. Clearing a tare value • The last selected fixed tare value memory is displayed. Press the F or TARE key to browse the requ...
Page 21 - BMI classification separated according to gender:; Hold function; Setting in Setting mode
21 ■ Error message when taring "Error 0 6 Taring not possible" Possible causes: • Scale empty• Scale in overload or underload• Manual tare input with tare value above maximum load ■ Displaying the tare memory To display the tare memory, press the INFO key and then the TARE key. Press the ZER...
Page 22 - Print; Configuring the printer port
ENGLISH Bed scale 7711 22 ■ Print The 3020 Digital Indicator can be connected to a printer via the serial port to print out scale chits. Up to a max. of 15 print templates can be stored. You can obtain a service software from Soehnle Profes-sional service centres for the 3020 /3030 to design print t...
Page 23 - Programming the F key; The following functions are available:
23 Default print templates, factory setting The print-command keys can be assigned using the print templates in the service software. In the fac-tory setting, the print template below is already stored and assigned. In other words, it can be prin-ted out. This default print template is an example sh...
Page 26 - TEChNICAL INFORMATION; Technical data; Other technical data
ENGLISH Bed scale 7711 26 7. TEChNICAL INFORMATION ■ Technical data Weighing range: see nameplate Division: see nameplate Min/max load: see nameplate Max. bed weight: 250 kg Approval number: D07-0 9-034-PTB (0102) Ambient operating temperature: –10°C to +40°C, rapid temperature changes, e.g. in the ...
Page 27 - XXXX; Max; XXXX; TYP
27 ■ Electronic nameplate and calibration counter The appliance has an electronic nameplate. Display by pressing the INFO key. Exit the display by pressing the INFO key again. (sample display) ■ Explanations of labels and icons Weighing ranges Maximum load of weighing range Minimum load of weighing ...
Page 28 - SN
ENGLISH Bed scale 7711 28 SN TYP BT IPX2 6V DC 80mA D07-09-034-PTB XXXX 07 D07-09-034-PTB XXXX 07 Symbol for EU calibration The calibrated counter status indicates how often the scale was calibrated. The stored counter status must match the calibrated counter status on the inserted label secured by ...
Page 29 - Scales, System Solutions And Special Developments
ENGLISH Bed scale 7711 29 Scales, System Solutions And Special Developments Soehnle Professional GmbH & Co. KG Manfred-von-Ardenne-Allee 12DE-71522 Backnang Phone +49 (0) 71 91 / 34 53 -0Fax +49 (0) 71 91 / 34 53 -211 [email protected] All r ig hts re ser ...