National Instruments VXI-MIO Series - Manuals
National Instruments VXI-MIO Series – Manual in PDF format online.
Manuals:
Manual National Instruments VXI-MIO Series
Summary
Important Information Warranty The VXI-MIO Series boards are warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves t...
National Instruments Corporation v VXI-MIO Series User Manual About This Manual Organization of This Manual ........................................................................................xiConventions Used in This Manual .......................................................................
Table of Contents VXI-MIO Series User Manual vi National Instruments Corporation Chapter 3Hardware Overview Analog Input ................................................................................................................. 3-3 Input Mode ...................................................
Table of Contents VXI-MIO Series User Manual viii National Instruments Corporation Appendix ASpecifications VXI-MIO-64E-1 ........................................................................................................... A-1VXI-MIO-64XE-10 ....................................................
Table of Contents VXI-MIO Series User Manual x National Instruments Corporation Tables Table 2-1. VXI-MIO Series DRAM Configuration .................................................. 2-6 Table 3-1. Available Input Configurations for the VXI-MIO Series ....................... 3-3 Table 3-2. Actual ...
About This Manual National Instruments Corporation xi VXI-MIO Series User Manual This manual describes the electrical and mechanical aspects of each module in the VXI-MIO Series product line and contains information concerning their installation, operation, and programming. Unless otherwise noted,...
About This Manual VXI-MIO Series User Manual xii National Instruments Corporation • Appendix C, Common Questions , contains a list of commonly asked questions and their answers relating to usage and special features of your VXI-MIO Series module. • Appendix D, Customer Communication , contains for...
About This Manual National Instruments Corporation xiii VXI-MIO Series User Manual National Instruments Documentation The VXI-MIO Series User Manual is one piece of the documentation set for your VXI-DAQ system. You could have any of several types of manuals depending on the hardware and software ...
About This Manual VXI-MIO Series User Manual xiv National Instruments Corporation Related Documentation The following National Instruments document contains information you may find helpful: • Application Note 025, Field Wiring and Noise Considerations for Analog Signals Customer Communication Nat...
National Instruments Corporation 1-1 VXI-MIO Series User Manual Introduction Chapter 1 This chapter describes the VXI-MIO Series modules, lists what you need to get started, describes the optional software and optional equipment, and explains how to unpack your VXI-MIO Series module. About the VXI...
Chapter 1 Introduction VXI-MIO Series User Manual 1-2 National Instruments Corporation What You Need to Get Started To set up and use your VXI-MIO Series module, you will need the following: ❑ One of the following modules: VXI-MIO-64E-1 VXI-MIO-64XE-10 ❑ VXI-MIO Series User Manual ❑ One or more of...
Chapter 1 Introduction National Instruments Corporation 1-3 VXI-MIO Series User Manual LabVIEW features interactive graphics, a state-of-the-art user interface, and a powerful graphical programming language. The LabVIEW Data Acquisition VI Library, a series of VIs for using LabVIEW with National I...
Chapter 1 Introduction VXI-MIO Series User Manual 1-4 National Instruments Corporation DAQ devices because it lets multiple devices operate at their peak performance. NI-DAQ also internally addresses many of the complex issues between the computer and the DAQ hardware such as programming interrupt...
Chapter 1 Introduction National Instruments Corporation 1-5 VXI-MIO Series User Manual Figure 1-1. The Relationship between the Programming Environment, Your Instrument Driver, and Your VXI-DAQ Hardware Optional Equipment National Instruments offers a variety of products to use with your VXI-MIO S...
Chapter 1 Introduction VXI-MIO Series User Manual 1-6 National Instruments Corporation Custom Cabling Mating connectors and a backshell kit for making custom 96-pin cables for your VXI-MIO Series module are available from National Instruments. If you want to develop your own cable, however, the fo...
National Instruments Corporation 2-1 VXI-MIO Series User Manual Configuration and Installation Chapter 2 This chapter explains how to configure and install your VXI-MIO Series module. Module Configuration The VXI-MIO Series modules are software-configurable, except for the VXIbus logical address. ...
Chapter 2 Configuration and Installation VXI-MIO Series User Manual 2-2 National Instruments Corporation Your VXI-MIO Series module does not support dynamic configuration of its logical address. Ensure that no other statically configurable VXIbus modules have the same logical address as the VXI-MI...
Chapter 2 Configuration and Installation National Instruments Corporation 2-5 VXI-MIO Series User Manual Figure 2-3. VXI-MIO-64XE-10 Logical Address Selection SIMM Size Each VXI-MIO module can accommodate up to two 1.35 in. DRAM SIMMs. Table 2-1 lists the SIMMS you can use. You can use 32-bit or 3...
Chapter 2 Configuration and Installation VXI-MIO Series User Manual 2-6 National Instruments Corporation accessible with the cover on. To access the SIMM sockets, perform the following steps: 1. Remove the four screws on the top, the four screws on the bottom, and the three screws on the right-sid...
Chapter 2 Configuration and Installation National Instruments Corporation 2-7 VXI-MIO Series User Manual Load USER/FACTORY Configuration The VXI-MIO module has an onboard EEPROM, which stores default register values that are loaded at power-on. The EEPROM is divided into two halves—a factory-confi...
Chapter 2 Configuration and Installation VXI-MIO Series User Manual 2-8 National Instruments Corporation Figure 2-5. Load User/Factory Configuration Protect/Change Factory Configuration Use switch S1 to change the factory-default configuration settings by permitting writes to the factory settings ...
Chapter 2 Configuration and Installation National Instruments Corporation 2-9 VXI-MIO Series User Manual 2. Remove or open any doors or covers blocking access to the mainframe slots. 3. If you are installing your VXI-DAQ module into a D-size mainframe, first install an appropriate support for C-si...
Chapter 2 Configuration and Installation VXI-MIO Series User Manual 2-10 National Instruments Corporation If you are using LabWindows/CVI, refer to your LabWindows/CVI release notes to install your application software. After you have installed LabWindows/CVI, refer to the NI-DAQ release notes and...
National Instruments Corporation 3-1 VXI-MIO Series User Manual Hardware Overview Chapter 3 This chapter presents an overview of the hardware functions on your VXI-MIO Series module. Figure 3-1 shows the block diagram for the VXI-MIO Series modules.
Chapter 3 Hardware Overview National Instruments Corporation 3-3 VXI-MIO Series User Manual Analog Input The analog input section of each VXI-MIO Series module is software configurable. You can select different analog input configurations through application software designed to control the VXI-MI...
Chapter 3 Hardware Overview VXI-MIO Series User Manual 3-4 National Instruments Corporation For more information about the three types of input configuration, refer to the Analog Input Signal Connections section in Chapter 4, Signal Connections , which contains diagrams showing the signal paths fo...
Chapter 3 Hardware Overview National Instruments Corporation 3-5 VXI-MIO Series User Manual ♦ VXI-MIO-64XE-10 This module has two input polarities—unipolar and bipolar. The VXI-MIO-64XE-10 has a unipolar input range of 10 V (0 to 10 V) and a bipolar input range of 20 V ( ± 10 V). You can program p...
Chapter 3 Hardware Overview VXI-MIO Series User Manual 3-6 National Instruments Corporation the overall input range and precision according to the configuration and gain used. Considerations for Selecting Input Ranges Which input polarity and range you select depends on the expected range of the i...
Chapter 3 Hardware Overview National Instruments Corporation 3-7 VXI-MIO Series User Manual Dither When you enable dither, you add approximately 0.5 LSB rms of white Gaussian noise to the signal to be converted by the ADC. This addition is useful for applications involving averaging to increase th...
Chapter 3 Hardware Overview VXI-MIO Series User Manual 3-8 National Instruments Corporation Figure 3-2. Dither You cannot disable dither on the VXI-MIO-64XE-10. This is because the ADC resolution is so fine that the ADC and the PGIA inherently produce almost 0.5 LSB rms of noise. This is equivalen...
Chapter 3 Hardware Overview National Instruments Corporation 3-9 VXI-MIO Series User Manual signal is connected to channel 1, and suppose the PGIA is programmed to apply a gain of one to channel 0 and a gain of 100 to channel 1. When the multiplexer switches to channel 1 and the PGIA switches to a...
Chapter 3 Hardware Overview VXI-MIO Series User Manual 3-10 National Instruments Corporation Analog Output ♦ VXI-MIO-64E-1 This module supplies two channels of analog output voltage at the I/O connector. The reference and range for the analog output circuitry is software-selectable. The reference ...
Chapter 3 Hardware Overview National Instruments Corporation 3-11 VXI-MIO Series User Manual ♦ VXI-MIO-64XE-10 You can configure each analog output channel for either unipolar or bipolar output. A unipolar configuration has a range of 0 to 10 V at the analog output. A bipolar configuration has a r...
Chapter 3 Hardware Overview VXI-MIO Series User Manual 3-12 National Instruments Corporation Note: The PFI0/TRIG1 pin is a high-impedance input. Therefore, it is susceptible to cross-talk from adjacent pins, which can result in false triggering when the pin is left unconnected. To avoid false trig...
Chapter 3 Hardware Overview National Instruments Corporation 3-13 VXI-MIO Series User Manual Figure 3-5. Above-High-Level Analog Triggering Mode In inside-region analog triggering mode, the trigger is generated when the signal value is between the lowValue and the highValue. Figure 3-6. Inside-Reg...
Chapter 3 Hardware Overview VXI-MIO Series User Manual 3-14 National Instruments Corporation In low-hysteresis analog triggering mode, the trigger is generated when the signal value is less than lowValue, with the hysteresis specified by highValue. Figure 3-8. Low-Hysteresis Analog Triggering Mode...
Chapter 3 Hardware Overview National Instruments Corporation 3-15 VXI-MIO Series User Manual Timing Signal Routing The DAQ-STC provides a very flexible interface for connecting timing signals to other modules or external circuitry. Your VXI-MIO Series module uses the VXIbus trigger for interconnec...
Chapter 3 Hardware Overview VXI-MIO Series User Manual 3-16 National Instruments Corporation This figure shows that CONVERT* can be generated from a number of sources, including the external signals VXI TTL Trig<0..4>, VXI ECL Trig<0..1>, and PFI<0..9>, and the internal signals S...
Chapter 3 Hardware Overview National Instruments Corporation 3-17 VXI-MIO Series User Manual VXIbus Triggers The VXI-MIO Series modules can use up to seven of the 10 VXIbus trigger lines to coordinate sampling and/or triggering across multiple modules. When using NI-DAQ software, the VXIbus trigge...
National Instruments Corporation 4-1 VXI-MIO Series User Manual Signal Connections Chapter 4 This chapter describes how to make input and output signal connections to your VXI-MIO Series module via the module I/O connector. The VXI-MIO-64E-1 and VXI-MIO-64XE-10 I/O connector has 96 pins that you c...
Chapter 4 Signal Connections National Instruments Corporation 4-3 VXI-MIO Series User Manual I/O Connector Signal Descriptions Signal Name Reference Direction Description AIGND — — Analog Input Ground—These pins are the reference point for single-ended measurements and the bias current return poin...
Chapter 4 Signal Connections National Instruments Corporation 4-9 VXI-MIO Series User Manual Analog Input Signal Connections The VXI-MIO-64E-1 and VXI-MIO-64XE-10 analog input signals are ACH<0..63>, AISENSE, AISENSE2, and AIGND. The ACH<0..63> signals are tied to the 64 analog input c...
Chapter 4 Signal Connections National Instruments Corporation 4-11 VXI-MIO Series User Manual ground. Your VXI-MIO Series module ADC measures this output voltage when it performs A/D conversions. You must reference all signals to ground either at the signal source or at the module. If you have a f...
Chapter 4 Signal Connections VXI-MIO Series User Manual 4-12 National Instruments Corporation Input Configurations You can configure your VXI-MIO Series module for one of three input modes—NRSE, RSE, or DIFF. The following sections discuss the use of single-ended and differential measurements and ...
Chapter 4 Signal Connections VXI-MIO Series User Manual 4-14 National Instruments Corporation Differential Connection Considerations (DIFF Input Configuration) A differential connection is one in which the VXI-MIO Series module analog input signal has its own reference signal or signal return path...
Chapter 4 Signal Connections National Instruments Corporation 4-17 VXI-MIO Series User Manual any resistors at all. This connection works well for DC-coupled sources with low source impedance (less than 100 Ω ). However, for larger source impedances, this connection leaves the differential signal ...
Chapter 4 Signal Connections VXI-MIO Series User Manual 4-18 National Instruments Corporation Single-Ended Connection Considerations A single-ended connection is one in which the VXI-MIO Series module analog input signal is referenced to a ground that can be shared with other input signals. The in...
Chapter 4 Signal Connections National Instruments Corporation 4-19 VXI-MIO Series User Manual Single-Ended Connections for Floating Signal Sources (RSE Configuration) Figure 4-6 shows how to connect a floating signal source to a channel on the VXI-MIO Series module configured for RSE mode. Figure ...
Chapter 4 Signal Connections VXI-MIO Series User Manual 4-20 National Instruments Corporation Figure 4-7. Single-Ended Input Connections for Ground-Referenced Signal Common-Mode Signal Rejection Considerations Figures 4-6 and 4-7 show connections for signal sources that are already referenced to s...
Chapter 4 Signal Connections National Instruments Corporation 4-21 VXI-MIO Series User Manual external reference input to be used by that channel. If you do not specify an external reference, the channel will use the internal reference. You cannot use an external analog output reference with the V...
Chapter 4 Signal Connections VXI-MIO Series User Manual 4-22 National Instruments Corporation Digital I/O Signal Connections The digital I/O signals are DIO<0..7> and DGND. DIO<0..7> are the signals making up the DIO port, and DGND is the ground reference signal for the DIO port. You c...
Chapter 4 Signal Connections National Instruments Corporation 4-23 VXI-MIO Series User Manual Figure 4-9 shows DIO<0, 2..3, 5..6> configured for digital input and DIO<1, 4, 7> configured for digital output. Digital input applications include receiving TTL signals and sensing external d...
Chapter 4 Signal Connections VXI-MIO Series User Manual 4-24 National Instruments Corporation Connections section later in this chapter. The general-purpose timing signals are explained in the General-Purpose Timing Signal Connections section later in this chapter. All digital timing connections a...
Chapter 4 Signal Connections National Instruments Corporation 4-25 VXI-MIO Series User Manual driver for the PFI2/CONVERT* pin. Be careful not to drive a PFI signal externally when it is configured as an output. As an input, you can individually configure each PFI for edge or level detection and a...
Chapter 4 Signal Connections VXI-MIO Series User Manual 4-26 National Instruments Corporation Figure 4-12. Typical Pretriggered Acquisition SCANCLK Signal SCANCLK is an output-only signal that generates a pulse with the leading edge occurring approximately 50 to 100 ns after an A/D conversion begi...
Chapter 4 Signal Connections National Instruments Corporation 4-27 VXI-MIO Series User Manual signal level. A 10 and 1.2 µ s clock is available for generating a sequence of eight pulses in the hardware-strobe mode. Figure 4-14 shows the timing for the hardware-strobe mode EXTSTROBE* signal. Figure...
Chapter 4 Signal Connections VXI-MIO Series User Manual 4-28 National Instruments Corporation Figure 4-15. TRIG1 Input Signal Timing Figure 4-16. TRIG1 Output Signal Timing The module also uses the TRIG1 signal to initiate pretriggered data acquisition operations. In most pretriggered applications...
Chapter 4 Signal Connections National Instruments Corporation 4-29 VXI-MIO Series User Manual scans before TRIG2 can be recognized. After the scan counter decrements to zero, it is loaded with the number of posttrigger scans to acquire while the acquisition continues. The module ignores the TRIG2 ...
Chapter 4 Signal Connections VXI-MIO Series User Manual 4-30 National Instruments Corporation STARTSCAN Signal Any PFI pin can externally input the STARTSCAN signal, which is available as an output on the PFI7/STARTSCAN pin. Refer to Figures 4-11 and 4-12 for the relationship of STARTSCAN to the d...
Chapter 4 Signal Connections National Instruments Corporation 4-31 VXI-MIO Series User Manual Figure 4-20. STARTSCAN Output Signal Timing The CONVERT* pulses are masked off until the module generates the STARTSCAN signal. If you are using internally generated conversions, the first CONVERT* will a...
Chapter 4 Signal Connections National Instruments Corporation 4-33 VXI-MIO Series User Manual Figure 4-22. CONVERT* Output Signal Timing The ADC switches to hold mode within 60 ns of the selected edge. This hold-mode delay time is a function of temperature and does not vary from one conversion to ...
Chapter 4 Signal Connections VXI-MIO Series User Manual 4-34 National Instruments Corporation AIGATE does not gate off conversions until the beginning of the next scan and, conversely, if conversions are being gated off, AIGATE does not gate them back on until the beginning of the next scan. SISOU...
Chapter 4 Signal Connections National Instruments Corporation 4-35 VXI-MIO Series User Manual As an input, the WFTRIG signal is configured in the edge-detection mode. You can select any PFI pin as the source for WFTRIG and configure the polarity selection for either rising or falling edge. The sel...
Chapter 4 Signal Connections VXI-MIO Series User Manual 4-36 National Instruments Corporation UPDATE* Signal Any PFI pin can externally input the UPDATE* signal, which is available as an output on the PFI5/UPDATE* pin. As an input, the UPDATE* signal is configured in the edge-detection mode. You c...
Chapter 4 Signal Connections National Instruments Corporation 4-37 VXI-MIO Series User Manual Figure 4-26. UPDATE* Input Signal Timing Figure 4-27. UPDATE* Output Signal Timing The DACs are updated within 100 ns of the leading edge. Separate the UPDATE* pulses with enough time that new data can be...
Chapter 4 Signal Connections VXI-MIO Series User Manual 4-38 National Instruments Corporation polarity selection for the PFI pin for either active high or active low. Figure 4-28 shows the timing requirements for the UISOURCE signal. Figure 4-28. UISOURCE Signal Timing The maximum allowed frequenc...
Chapter 4 Signal Connections VXI-MIO Series User Manual 4-40 National Instruments Corporation Figure 4-30. GPCTR0_GATE Signal Timing in Edge-Detection Mode GPCTR0_OUT Signal This signal is available only as an output on the GPCTR0_OUT pin. The GPCTR0_OUT signal reflects the terminal count (TC) of ...
Chapter 4 Signal Connections VXI-MIO Series User Manual 4-42 National Instruments Corporation configure the polarity selection for either rising or falling edge. You can use the gate signal in a variety of different applications to perform such actions as starting and stopping the counter, generat...
Chapter 4 Signal Connections National Instruments Corporation 4-45 VXI-MIO Series User Manual Field Wiring Considerations Environmental noise can seriously affect the accuracy of measurements made with your VXI-MIO Series module if you do not take proper care when running signal wires between sign...
National Instruments Corporation 5-1 VXI-MIO Series User Manual Calibration Chapter 5 This chapter discusses the calibration procedures for your VXI-MIO Series module. NI-DAQ and the VXI plug&play instrument drivers include calibration functions for performing all of the steps in the calibrati...
Chapter 5 Calibration VXI-MIO Series User Manual 5-2 National Instruments Corporation the CalDACs with values either from the original factory calibration or from a calibration that you subsequently performed. This method of calibration is not very accurate because it does not take into account th...
Chapter 5 Calibration National Instruments Corporation 5-3 VXI-MIO Series User Manual module by calling the NI-DAQ or VXI plug&play instrument driver calibration function. To externally calibrate your module, be sure to use a very accurate external reference. The reference should be several ti...
National Instruments Corporation A-1 VXI-MIO Series User Manual Specifications Appendix A This appendix lists the specifications of each module in the VXI-MIO Series. These specifications are typical at 25 ° C unless otherwise noted. VXI-MIO-64E-1 Analog Input Input Characteristics Number of chann...
Appendix A Specifications for VXI-MIO-64E-1 VXI-MIO Series User Manual A-2 National Instruments Corporation Input coupling .................................... DC Max working voltage (signal + common mode)................. Each input should remain within ± 11 V of ground Overvoltage protection ......
Appendix A Specifications for VXI-MIO-64E-1 National Instruments Corporation A-3 VXI-MIO Series User Manual Transfer Characteristics Relative accuracy ............................. ± 0.5 LSB typ dithered, ± 1.5 LSB max undithered DNL .................................................. ± 0.5 LSB typ...
Appendix A Specifications for VXI-MIO-64E-1 VXI-MIO Series User Manual A-4 National Instruments Corporation Dynamic Characteristics Crosstalk ............................................ -70 dB, DC to 100 kHz Stability Recommended warm-up time ............. 15 min Offset temperature coefficient Pr...
Appendix A Specifications for VXI-MIO-64E-1 VXI-MIO Series User Manual A-6 National Instruments Corporation Gain error (relative to external reference) ........... +0% to +0.5% of output max, not adjustable Voltage Output Ranges ............................................... ± 5 V, 0 to 10 V, ± E...
Appendix A Specifications for VXI-MIO-64E-1 National Instruments Corporation A-7 VXI-MIO Series User Manual Onboard calibration reference Level ........................................... 5.000 V ( ± 0.5 mV) (actual value stored in EEPROM) Temperature coefficient .............. ± 0.6 ppm/ ° C max ...
Appendix A Specifications for VXI-MIO-64E-1 VXI-MIO Series User Manual A-8 National Instruments Corporation Frequency scalers ....................... 10 MHz, 100 kHz Base clock accuracy ........................... ± 0.01% Max source frequency ........................ 20 MHz Min source pulse durati...
Appendix A Specifications for VXI-MIO-64E-1 National Instruments Corporation A-9 VXI-MIO Series User Manual Power Requirement +5 VDC ............................................. 1.80 A typ; 2.16 A max* (*Not including current used by accessories.) -5.2 VDC ...........................................
Appendix A Specifications for VXI-MIO-64XE-10 VXI-MIO Series User Manual A-14 National Instruments Corporation Stability Offset temperature coefficient ............ ± 50 µ V/ ° C Gain temperature coefficient .............. ± 7.5 ppm/ ° C Onboard calibration reference Level ...........................
Appendix A Specifications for VXI-MIO-64XE-10 National Instruments Corporation A-15 VXI-MIO Series User Manual Timing I/O Number of channels .......................... 2 up/down counter/timers, 1 frequency scaler Resolution Counter/timers ............................ 24 bits Frequency scaler ........
Appendix A Specifications for VXI-MIO-64XE-10 VXI-MIO Series User Manual A-16 National Instruments Corporation External input (PFI0/TRIG1) Impedance .................................. 10 k Ω Coupling ..................................... DC Protection ................................... -0.5 to 5....
National Instruments Corporation C-1 VXI-MIO Series User Manual Common Questions Appendix C This appendix contains a list of commonly asked questions and their answers relating to usage and special features of your VXI-MIO Series module. General Information 1. What is the DAQ-STC? The DAQ-STC is t...
Appendix C Common Questions VXI-MIO Series User Manual C-2 National Instruments Corporation 3. What type of 5 V protection do the VXI-MIO Series modules have? The VXI-MIO Series modules have 5 V lines equipped with a self-resetting 1 A fuse. Installation and Configuration 4. What jumpers should I ...
Appendix C Common Questions National Instruments Corporation C-3 VXI-MIO Series User Manual while maintaining a high common-mode rejection ratio (CMRR). These methods are outlined in Chapter 4, Signal Connections . 9. Can I sample across a number of channels on a VXI-MIO Series module while each c...
Appendix C Common Questions VXI-MIO Series User Manual C-4 National Instruments Corporation a. Enable the PFI5 line for output, as follows: If you are using NI-DAQ, call Select_Signal(deviceNumber, ND_PFI_5, ND_OUT_UPDATE, ND_HIGH_TO_LOW) . If you are using LabVIEW, invoke the Route Signal VI with...
Appendix C Common Questions National Instruments Corporation C-5 VXI-MIO Series User Manual analog triggering, selectable logic level, and frequency shift keying. The DAQ-STC also makes buffered operations possible, such as direct up/down control, single or pulse train generation, equivalent time ...
Appendix C Common Questions National Instruments Corporation C-6 VXI-MIO Series User Manual Gate Config, CTR Mode Config, and CTR Pulse Config advanced level VIs to indicate which function the connected signal will serve. Use the Route Signal VI to enable the PFI lines to output internal signals. ...
National Instruments Corporation D-1 VXI-MIO Series User Manual Customer Communication Appendix D For your convenience, this appendix contains forms to help you gather the information necessary to help us solve your technical problems and a form you can use to comment on the product documentation....
FaxBack is a 24-hour information retrieval system containing a library of documents on a wide range of technical information. You can access FaxBack from a touch-tone telephone at (512) 418-1111. You can submit technical support questions to the appropriate applications engineering team through e-ma...
Technical Support Form Photocopy this form and update it each time you make changes to your software or hardware, and use the completed copy of this form as a reference for your current configuration. Completing this form accurately before contacting National Instruments for technical support helps ...
Documentation Comment Form National Instruments encourages you to comment on the documentation supplied with our products. This information helps us provide quality products to meet your needs. Title: VXI-MIO Series User Manual Edition Date: August 1996 Part Number: 321246A-01 Please comment on the ...
National Instruments Corporation G-1 VXI-MIO Series User Manual Symbols ˚ degree – negative of, or minus Ω ohm / per % percent ± plus or minus + positive of, or plus square root of +5V +5 VDC source signal Prefix Meaning Value p- pico- 10 - 12 n- nano- 10 - 9 µ - micro- 10 - 6 m- milli- 10 - 3 k- ...
Glossary VXI-MIO Series User Manual G-12 National Instruments Corporation plug and play devices Devices that do not require dip switches or jumpers to configure resources on the devices—also called switchless devices. port (1) A communications connection on a computer or a remote controller. (2) A...
National Instruments Corporation I -1 VXI-MIO Series User Manual Index Numbers +5 V signal description, 4-3power connections, 4-23VXI-MIO-64E-1 (table), 4-6VXI-MIO-64XE-10 (table), 4-8 A ACH<0..15> signal (table), 4-3ACH<0..63> signal analog input connections, 4-9VXI-MIO-64XE-10 (table...
Index National Instruments Corporation I -3 VXI-MIO Series User Manual D DAC0OUT signal analog output connections, 4-20 to 4-21description (table), 4-3VXI-MIO-64E-1 (table), 4-6VXI-MIO-64XE-10 (table), 4-8 DAC1OUT signal analog output connections, 4-20 to 4-21description (table), 4-3VXI-MIO-64E-1 ...
Index VXI-MIO Series User Manual I -4 National Instruments Corporation e-mail support, D-2environment specifications VXI-MIO-64E-1, A-9VXI-MIO-64XE-10, A-16 environmental noise, avoiding, 4-45equipment, optional, 1-5EXTREF signal analog output connections, 4-20 to 4-21analog output reference selec...
Index National Instruments Corporation I -5 VXI-MIO Series User Manual H hardware installation, 2-8 to 2-9hardware overview analog input, 3-3 to 3-9 considerations for selecting input ranges, 3-6 dither, 3-7 to 3-8input modes, 3-3 to 3-4input polarity and range, 3-4 to 3-6multichannel scanning con...
Index VXI-MIO Series User Manual I -6 National Instruments Corporation L LabVIEW and LabWindows/CVI software, 1-3 M manual. See documentation. memory. See SIMM size configuration. multichannel scanning, 3-8 to 3-9 N NI-DAQ driver software, 1-3 to 1-4noise, avoiding, 4-45NRSE (nonreferenced single-...
National Instruments Manuals
-
National Instruments SCC-AI01
Manual
-
National Instruments USB-6008/6009
Manual
-
National Instruments 7334
Manual
-
National Instruments NI 9403E
Manual
-
National Instruments DIO 6533
Manual
-
National Instruments NI PCI-5114
Manual
-
National Instruments 1000DC
Manual
-
National Instruments 321518A-01
Manual
-
National Instruments NI 5672
Manual
-
National Instruments USB-9221
Manual
-
National Instruments PCI
Manual
-
National Instruments NI 9229
Manual
-
National Instruments 6211
Manual
-
National Instruments NI 9217
Manual
-
National Instruments NI USB-6009
Manual
-
National Instruments NI sbRIO-960x
Manual
-
National Instruments 6024E
Manual
-
National Instruments 3.x
Manual
-
National Instruments NI 784xR
Manual
-
National Instruments NI-Motion
Manual