Limited Warranty The SCXI-1163 is warranted against defects in materials and workmanship for a period of one year from the date ofshipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replaceequipment that proves to be defective during the war...
© National Instruments Corporation v SCXI-1163 User Manual Contents About This Manual ............................................................................................................. xi Organization of This Manual ............................................................................
Contents © National Instruments Corporation vii SCXI-1163 User Manual Appendix ESCXI-1163 Cabling ............................................................................................................. E-1 SCXI-1340 Cable Assembly ..................................................................
Contents SCXI-1163 User Manual viii © National Instruments Corporation Figures Figure 1-1. SCXI-1163 Digital Output Module .................................................................... 1-1 Figure 2-1. SCXI-1163 Parts Locator Diagram ...............................................................
© National Instruments Corporation ix SCXI-1163 User Manual About This Manual This manual describes the electrical and mechanical aspects of the SCXI-1163 and containsinformation concerning its operation and programming. The SCXI-1163 is a member of theNational Instruments Signal Conditioning eXtens...
About This Manual SCXI-1163 User Manual x © National Instruments Corporation • The Glossary contains an alphabetical list and description of terms used in this manual, including abbreviations, acronyms, metric prefixes, mnemonics, and symbols. • The Index contains an alphabetical list of key terms a...
About This Manual © National Instruments Corporation xi SCXI-1163 User Manual Abbreviations, acronyms, metric prefixes, mnemonics, symbols, and terms are listed in theGlossary. Related Documentation The following documents contain information that you may find helpful as you read this manual: • AT-D...
About This Manual SCXI-1163 User Manual xii © National Instruments Corporation Customer Communication National Instruments wants to receive your comments on our products and manuals. We areinterested in the applications you develop with our products, and we want to help if you haveproblems with them...
© National Instruments Corporation 1-1 SCXI-1163 User Manual Chapter 1Introduction This chapter describes the SCXI-1163; lists the contents of your SCXI-1163 kit; describes theoptional software, optional equipment, and custom cables; and explains how to unpack theSCXI-1163 kit. Figure 1-1 shows the ...
Introduction Chapter 1 SCXI-1163 User Manual 1-2 © National Instruments Corporation With the SCXI-1163, you can use the SCXI chassis as a controller in laboratory testing,production testing, and industrial-process monitoring. What You Need To Get Started SCXI-1163 module SCXI-1163 User Manual SCXI c...
Chapter 1 Introduction © National Instruments Corporation 1-3 SCXI-1163 User Manual You can also use the SCXI-1163, combined with the NB Series data acquisition boards, withNI-DAQ software for Macintosh. NI-DAQ software for Macintosh, which is shipped with allNational Instruments Macintosh data acqu...
Introduction Chapter 1 SCXI-1163 User Manual 1-4 © National Instruments Corporation • ERNI Components, Inc. (part number 033-273) The mating connector for the SCXI-1163 front connector is a special 48-pin reversed DIN Cfemale connector. National Instruments uses a polarized and keyed connector to pr...
© National Instruments Corporation 2-1 SCXI-1163 User Manual Chapter 2Configuration and Installation This chapter describes the SCXI-1163 jumper configurations, installation of the SCXI-1163 intothe SCXI chassis, signal connections to the SCXI-1163, and cable wiring. Module Configuration The SCXI-11...
Chapter 2 Configuration and Installation © National Instruments Corporation 2-3 SCXI-1163 User Manual The SCXI-1163 can accept data in two forms–serial and parallel. Serial data is transferred acrossthe SCXIbus using the Serial Peripheral Interface (SPI) protocol. Using serial communication,one data...
Configuration and Installation Chapter 2 SCXI-1163 User Manual 2-4 © National Instruments Corporation Do not operate damaged equipment. The safety protection features built into thismodule can become impaired if the module becomes damaged in any way. If it isdamaged, turn the module off and do not u...
Chapter 2 Configuration and Installation © National Instruments Corporation 2-5 SCXI-1163 User Manual - Jumper W5 carries the SCXIbus MISO line, after buffering, to the SERDATOUT signalon the rear signal connector. - Jumper W6 selects the primary operating mode, either serial or parallel, and config...
Configuration and Installation Chapter 2 SCXI-1163 User Manual 2-6 © National Instruments Corporation Position PAR disconnects SERDATOUT from the SCXIbus MISO line. Use this position whenyou will connect the module in parallel to a data acquisition board. Using Jumpers W4 and W5 If a module is not c...
Chapter 2 Configuration and Installation © National Instruments Corporation 2-7 SCXI-1163 User Manual Table 2-1. Configuration of Jumpers W2, W3, and W5 for DIO-Type and MIO-Type Boards Jumper Description Configuration for DIO-Type Board Configuration for MIO-Type Board W2 W3 W5 W5 Configures rear c...
Configuration and Installation Chapter 2 SCXI-1163 User Manual 2-8 © National Instruments Corporation Hardware Installation You can install the SCXI-1163 in any available SCXI chassis. After you have made anynecessary changes and have verified and recorded the jumper settings on the form in Appendix...
Chapter 2 Configuration and Installation © National Instruments Corporation 2-9 SCXI-1163 User Manual Front Connector Figure 2-2 shows the pin assignments for the SCXI-1163 front connector. Pin Number Signal Name Column A B C Signal Name 30 29 26 25 22 21 18 17 14 13 10 9 6 5 2 1 Out 0Out 1Out 2Out ...
Configuration and Installation Chapter 2 SCXI-1163 User Manual 2-10 © National Instruments Corporation Front Connector Signal Descriptions Pin Signal Name Description B30, A30, Out<0..3> Port 0 outputs B29, A29 C30 Vcc Port 0 power C29 GND Port 0 ground B26, A26, Out<4..7> Port 1 outputs...
Chapter 2 Configuration and Installation © National Instruments Corporation 2-11 SCXI-1163 User Manual Pin Signal Name Description (continued) A1, B1, A2, Out<28..31> Port 7 outputs B2 C2 GND Port 7 ground C1 Vcc Port 7 power The SCXI-1163 consists of eight ports of four optically isolated dig...
Configuration and Installation Chapter 2 SCXI-1163 User Manual 2-12 © National Instruments Corporation When using the terminal block with high common-mode voltages, you mustinsulate your signal wires appropriately. National Instruments is not liable for anydamages or injuries resulting from inadequa...
Configuration and Installation Chapter 2 SCXI-1163 User Manual 2-14 © National Instruments Corporation SCXI-1326 Installation To connect the terminal block to the SCXI-1163 front connector, follow these steps: 1. Connect the SCXI-1163 front connector to its mating connector on the terminal block. 2....
Chapter 2 Configuration and Installation © National Instruments Corporation 2-15 SCXI-1163 User Manual 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 SERDATIN DAQD*/A SLOT0SEL* (MIO) SERCLK DIG GND (MIO) SE...
Chapter 2 Configuration and Installation © National Instruments Corporation 2-17 SCXI-1163 User Manual All other pins are not connected. The signals on the rear signal connector are digital I/O signals. Signal connection guidelines foreach of these groups are given in the following section. Serial I...
Configuration and Installation Chapter 2 SCXI-1163 User Manual 2-18 © National Instruments Corporation When you configure the SCXI-1163 for an MIO-type board, the digital I/O signals of theSCXI-1163 match the digital I/O lines of the MIO board. When you use the SCXI-1163 with anSCXI-1341, SCXI-1342,...
Chapter 2 Configuration and Installation © National Instruments Corporation 2-19 SCXI-1163 User Manual Timing Requirements and Communication Protocol Communication Signals This section describes the methods for communicating on the Serial Peripheral Interface (SPI)bus and their timing requirements. ...
Configuration and Installation Chapter 2 SCXI-1163 User Manual 2-20 © National Instruments Corporation To write the 16-bit slot-select number to Slot 0, follow these steps: 1. Initial conditions: SERDATIN = don't care.DAQD*/A = 1.SLOT0SEL* = 1.SERCLK = 1. 2. Clear SLOT0SEL* to 0. This deasserts all ...
Chapter 2 Configuration and Installation © National Instruments Corporation 2-21 SCXI-1163 User Manual To write to the Address Handler, follow these steps: 1. Initial conditions: SS* asserted low.SERDATIN = don't care.DAQD*/A = 1 (indicates data will be written to the Address Handler).SLOT0SEL* = 1....
Configuration and Installation Chapter 2 SCXI-1163 User Manual 2-22 © National Instruments Corporation To write to the Data Register, follow these steps: 1. Initial conditions: SS* asserted low.SERDATIN = don't care.DAQD*/A = 0 (indicates data will be written to a Register).SLOT0SEL* = 1.SERCLK = 1 ...
Chapter 2 Configuration and Installation © National Instruments Corporation 2-23 SCXI-1163 User Manual To read from the Module ID Register, follow these steps: 1. Initial conditions: SS* asserted low.SERDATIN = don't care.DAQD*/A = 0. = 1.SERCLK = 1 (and has not changed since DAQD*/A went low). 2. F...
Configuration and Installation Chapter 2 SCXI-1163 User Manual 2-24 © National Instruments Corporation To read from a Status Register, follow these steps: 1. Initial conditions: SS* asserted low.SERDATIN = don't care.DAQD*/A = 0. = 1.SERCLK = don't care. 2. The Status Registers are 1-bit read-only r...
© National Instruments Corporation 3-1 SCXI-1163 User Manual Chapter 3Theory of Operation This chapter contains a functional overview of the SCXI-1163 module and explains the operationof each functional unit making up the SCXI-1163. Functional Overview The block diagram in Figure 3-1 shows the key f...
Theory of Operation Chapter 3 SCXI-1163 User Manual 3-2 © National Instruments Corporation INTR* D*/A CHSGNDCHSGND V+V+ +5 V MOSI A1B1A2B2A3B3A4B4A5B5A6B6A7B7A8B8A9B9A10B10A11B11A12B12A13B13A14B14A15B15A16B16A17B17A18B18A19B19A20B20A21B21A22B22A23B23A24B24 D1C1D2C2D3C3D4C4D5C5D6C6D7C7D8C8D9C9D10C10D...
Chapter 3 Theory of Operation © National Instruments Corporation 3-3 SCXI-1163 User Manual SCXIbus Connector Signal Descriptions Pin Signal Name Description A19 RESET* Reset – When pulled low, reinitializes the module to itspower-up state. Totem pole. Input. B19 MISO Master-In-Slave-Out – Transmits ...
Theory of Operation Chapter 3 SCXI-1163 User Manual 3-4 © National Instruments Corporation Table 3-1. SCXIbus Equivalents for Rear Signal Connector Rear Signal Connector Signal SCXIbus Equivalent SERDATIN MOSI DAQD*/A D*/A SLOT0SEL* INTR* SERCLK SPICLK SERDATOUT MISO When the primary mode of operati...
Chapter 3 Theory of Operation © National Instruments Corporation 3-5 SCXI-1163 User Manual This circuitry is divided into an SCXI digital interface section and two signal routing sections.The SCXI digital interface buffers signals from the SCXIbus to the module and drives signalsfrom the module onto...
Theory of Operation Chapter 3 SCXI-1163 User Manual 3-6 © National Instruments Corporation The register circuitry section consists of the Data Register, the Module ID Register, the OutputMode Register, and the Primary Mode Status Register. The Data Register is a 4-byte serial-in parallel-out shift r...
Chapter 3 Theory of Operation © National Instruments Corporation 3-7 SCXI-1163 User Manual output channels and the Vcc and ground connections. Table 3-2 shows the channel and portassignments. These outputs are open-collector outputs with 4.7 k Ω pullups, which can sink 12 mA while maintaining an out...
© National Instruments Corporation 4-1 SCXI-1163 User Manual Chapter 4Register Descriptions This chapter describes in detail the SCXI-1163 Address Handler, the Module ID Register, theData Register, the Status registers, and the SCXI-1000/1001 Slot 0 registers. Note: If you plan to use a programming ...
Register Descriptions Chapter 4 SCXI-1163 User Manual 4-2 © National Instruments Corporation Address Handler You must write to the Address Handler at the beginning of each write to or read from theSCXI-1163. Write the address of the register of interest to this handler, which in turn enables theregi...
Register Descriptions Chapter 4 SCXI-1163 User Manual 4-4 © National Instruments Corporation Data Register The Data Register contains 32 bits that control the state of each output of the SCXI-1163.Whenever the Data Register is selected by the Address Handler, the Data Register shifts in thedata pres...
Chapter 4 Register Descriptions © National Instruments Corporation 4-5 SCXI-1163 User Manual Status Registers The Status Registers are 1-bit read-only registers that indicate the primary (jumper-set) mode ofoperation and the mode of operation currently driving the outputs. The register at address 00...
Register Descriptions Chapter 4 SCXI-1163 User Manual 4-6 © National Instruments Corporation Parking Register This register is a dummy register that you should select after the end of a read or write operation.Selecting the Parking Register places the module in a state insensitive to noise and toele...
Chapter 4 Register Descriptions © National Instruments Corporation 4-7 SCXI-1163 User Manual Slot 0 Register Descriptions Slot 0 has three registers–the FIFO Register, the Hardscan Register, and the Slot-Select Register.Only the Slot-Select Register is relevant to this module. The Slot-Select Regist...
Register Descriptions Chapter 4 SCXI-1163 User Manual 4-8 © National Instruments Corporation Slot-Select Register The Slot-Select Register contains 16 bits that determine which module in which chassis isenabled for communication when the SLOT0SEL* line is high. An SCXI-1000 chassis selectsthe approp...
© National Instruments Corporation 5-1 SCXI-1163 User Manual Chapter 5Programming This chapter contains a functional programming description of the SCXI-1163 and Slot 0. Note: If you plan to use a programming software package such as NI-DAQ, LabWindows, or LabVIEW with your SCXI-1163 board, you do n...
Programming Chapter 5 SCXI-1163 User Manual 5-2 © National Instruments Corporation Table 5-1. SCXIbus to SCXI-1163 Rear Signal Connector to Data Acquisition Board Pin Equivalences SCXIbus Line SCXI-1163 Rear Signal Connector MIO Boards Lab-NB/Lab-PC/ Lab-PC+/Lab-LC PC-LPM-16 DIO-24 DIO-96 DIO-32F MO...
Chapter 5 Programming © National Instruments Corporation 5-3 SCXI-1163 User Manual 5. If you are writing to a Data Register, you must first write address 0001 (hexadecimal) or address 0006 (hexadecimal) to the Address Handler. See Chapter 4, Register Descriptions , for a discussion on the uses of th...
Programming Chapter 5 SCXI-1163 User Manual 5-4 © National Instruments Corporation Examples This section describes how to program the SCXI-1163, either alone or in conjunction with othermodules. The following examples are intended to aid your understanding of module and Slot 0programming. It will be...
Chapter 5 Programming © National Instruments Corporation 5-5 SCXI-1163 User Manual Example 3 You have a multiple-chassis system with an SCXI-1163 in Slots 4 and 8 of Chassis 1, andanother SCXI-1163 in Slot 11 of Chassis 2. The SCXI-1163 in Slot 8 of Chassis 1 is configuredfor a primary mode of opera...
© National Instruments Corporation A-1 SCXI-1163 User Manual Appendix ASpecifications This appendix lists the specifications for the SCXI-1163. These are typical at 25 ° C and 50% humidity unless otherwise stated. The operating temperature range is 0 ° to 50 ° C. Digital Outputs Power requirements (...
Specifications Appendix A SCXI-1163 User Manual A-2 © National Instruments Corporation Operating Environment Temperature 0 ° to 50 ° C Relative humidity 5% to 90% at 35 ° C Storage Environment Temperature -55 ° to 150 ° C Relative humidity 5% to 90% noncondensing
SCXIbus Connector Appendix C SCXI-1163 User Manual C-2 © National Instruments Corporation INTR* D*/A CHSGNDCHSGND V+V+ +5 V MOSI A1B1A2B2A3B3A4B4A5B5A6B6A7B7A8B8A9B9A10B10A11B11A12B12A13B13A14B14A15B15A16B16A17B17A18B18A19B19A20B20A21B21A22B22A23B23A24B24 D1C1D2C2D3C3D4C4D5C5D6C6D7C7D8C8D9C9D10C10D1...
Appendix C SCXIbus Connector © National Instruments Corporation C-3 SCXI-1163 User Manual SCXIbus Connector Signal Descriptions Pin Signal Name Description A19 RESET* Reset – When pulled low, reinitializes the module to itspower-up state. Totem pole. Input. B19 MISO Master-In-Slave-Out – Transmits d...
© National Instruments Corporation E-1 SCXI-1163 User Manual Appendix ESCXI-1163 Cabling This appendix describes how to use and install the hardware accessories for the SCXI-1163: • SCXI-1340 cable assembly • SCXI-1341 Lab-NB, Lab-PC, and Lab-PC+ cable assembly • SCXI-1344 Lab-LC cable assembly • SC...
SCXI-1163 Cabling Appendix E SCXI-1163 User Manual E-2 © National Instruments Corporation • The SCXI-1340 has an extra male breakout connector for use with the SCXI-1180feedthrough panel or additional modules or breadboards that need a direct connection to theMIO-16 or DIO-24 board. • The SCXI-1340 ...
Appendix E SCXI-1163 Cabling © National Instruments Corporation E-3 SCXI-1163 User Manual SCXI-1340 Installation Follow these steps to install the SCXI-1340: 1. Make sure that the computer and the SCXI chassis are turned off. 2. Install the SCXI module in the chassis. 3. Plug the mounting bracket co...
SCXI-1163 Cabling Appendix E SCXI-1163 User Manual E-4 © National Instruments Corporation SCXI-1341 Lab-NB, Lab-PC, or Lab-PC+ and SCXI-1344Lab-LC Cable Assembly The SCXI-1341 Lab-NB, Lab-PC, or Lab-PC+ cable assembly connects a Lab-NB, Lab-PC, orLab-PC+ board to an SCXI-1163 module. The SCXI-1344 L...
Appendix E SCXI-1163 Cabling © National Instruments Corporation E-5 SCXI-1163 User Manual SCXI-1341 and SCXI-1344 Installation Follow these steps to install the SCXI-1341 or SCXI-1344: 1. Make sure that the computer and the SCXI chassis are turned off. 2. Install the SCXI module in the chassis. 3. C...
SCXI-1163 Cabling Appendix E SCXI-1163 User Manual E-6 © National Instruments Corporation Table E-3. SCXI-1342 Pin Translations PC-LPM-16 Pin PC-LPM-16 Signal Rear Signal Connector Pin SCXI-1163 Use 1-2 AIGND 1-2 No Connect 3 ACH0 3 No Connect 4 ACH8 4 No Connect 5 ACH1 5 No Connect 6 ACH9 6 No Conn...
Appendix E SCXI-1163 Cabling © National Instruments Corporation E-7 SCXI-1163 User Manual DIO-96, AT-MIO-16D, and AT-MIO-64F-5 BoardConnection To use your SCXI-1163 with a DIO-96, AT-MIO-16D, or AT-MIO-64F-5 board, you need anNB5 cable. The NB5 cable is a ribbon cable with a 100-pin connector that m...
Appendix E SCXI-1163 Cabling © National Instruments Corporation E-9 SCXI-1163 User Manual Table E-4. SCXI-1163 and DIO-96, AT-MIO-16D, and AT-MIO-64F-5 Board Pinout Equivalences (Continued) Pin SCXI-1163 Rear Signal Connector DIO-96 Board Equivalent AT-MIO-16D Board Equivalent AT-MIO-64F-5 Board Equ...
SCXI-1163 Cabling Appendix E SCXI-1163 User Manual E-12 © National Instruments Corporation SCXI-1348 Installation Follow these steps to install the SCXI-1348: 1. Make sure that the computer and the SCXI chassis are turned off. 2. Install the SCXI module to which the SCXI-1348 will connect. 3. Connec...
SCXI-1163 Cabling Appendix E SCXI-1163 User Manual E-14 © National Instruments Corporation Front Panel Connector Front Panel Front Threaded Strip Ribbon Cable to Rear and Breakout Connectors Step 5 Figure E-4. SCXI-1180 Front Panel Installation SCXI-1302 50-Pin Terminal Block The SCXI-1302 terminal ...
Appendix E SCXI-1163 Cabling © National Instruments Corporation E-15 SCXI-1163 User Manual 50-Pin Connector Grounding Screw Thumbscrew Cutout Step 1 Step 2 Insert Screwdriver in Groove and Rotate to Pry Open Figure E-5. Cover Removal SCXI-1302 Installation Follow these steps to install the SCXI-1302...
SCXI-1163 Cabling Appendix E SCXI-1163 User Manual E-16 © National Instruments Corporation SCXI-1351 Installation Follow these steps to install the SCXI-1351: 1. Make sure that the computer and the SCXI chassis are turned off. 2. Install the SCXI module in the chassis. 3. Connect the rear connector ...
Appendix E SCXI-1163 Cabling © National Instruments Corporation E-17 SCXI-1163 User Manual 4. Connect another ribbon cable to the chassis extender connector in the middle of the SCXI-1350. 5. Plug the SCXI-1350 into the back of the SCXI module in the first chassis so that the module rear connector m...
© National Instruments Corporation F-1 SCXI-1163 User Manual Appendix FCustomer Communication For your convenience, this appendix contains forms to help you gather the information necessaryto help us solve technical problems you might have as well as a form you can use to comment onthe product docum...
SCXI-1163 Hardware Configuration Form Record the settings and revisions of your hardware and software on the line to the right of each item. Complete anew copy of this form each time you revise your software or hardware configuration, and use this form as areference for your current configuration. C...
Documentation Comment Form National Instruments encourages you to comment on the documentation supplied with our products. Thisinformation helps us provide quality products to meet your needs. Title: SCXI-1163 User Manual Edition Date: September 1994 Part Number: 320576-01 Please comment on the comp...
© National Instruments Corporation Glossary-1 SCXI-1163 User Manual Glossary ___________________________________________________ Prefix Meaning Value p- pico- 10- 12 n- nano- 10- 9 µ - micro- 10- 6 m- milli- 10- 3 k- kilo- 10 3 M- mega- 10 6 ˚ degrees Ω ohms +5 V (signal) +5 VDC Source A amperes AC ...
© National Instruments Corporation Index- 1 SCXI-1163 User Manual Index Numbers +5 V signal, 3-3, C-3 A Address Handler description, 4-2register addresses, 4-2selecting Data Register, 3-6timing diagram, 2-21writing to Address Handler, 2-21, 5-3 analog backplane protection, 3-7AT-MIO board connection...
Index © National Instruments Corporation Index- 7 SCXI-1163 User Manual equivalents for rear signal connector, 3-4 pin assignments, 3-2signal descriptions, 3-3 to 3-4 timing requirements and communication protocol. See communication signals. U unpacking the SCXI-1163 module, 1-4 V V+ signal, 3-3, C-...
National Instruments Manuals
-
National Instruments SCC-AI01
Manual
-
National Instruments USB-6008/6009
Manual
-
National Instruments 7334
Manual
-
National Instruments NI 9403E
Manual
-
National Instruments DIO 6533
Manual
-
National Instruments NI PCI-5114
Manual
-
National Instruments 1000DC
Manual
-
National Instruments 321518A-01
Manual
-
National Instruments NI 5672
Manual
-
National Instruments USB-9221
Manual
-
National Instruments PCI
Manual
-
National Instruments NI 9229
Manual
-
National Instruments 6211
Manual
-
National Instruments NI 9217
Manual
-
National Instruments NI USB-6009
Manual
-
National Instruments NI sbRIO-960x
Manual
-
National Instruments 6024E
Manual
-
National Instruments 3.x
Manual
-
National Instruments NI 784xR
Manual
-
National Instruments NI-Motion
Manual