Page 3 - Important Information
Important Information Warranty The PXI-1006 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced byreceipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective ...
Page 4 - Compliance; FCC/Canada Radio Frequency Interference Compliance*; Determining FCC Class; Class A; Class B
Compliance FCC/Canada Radio Frequency Interference Compliance* Determining FCC Class The Federal Communications Commission (FCC) has rules to protect wireless communications from interference. The FCCplaces digital electronics into two classes. These classes are known as Class A (for use in industri...
Page 5 - European Union - Compliance to EEC Directives
Canadian Department of Communications This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. European Union - Compliance t...
Page 6 - Contents; About This Manual
© National Instruments Corporation vii PXI-1006 User Manual Contents About This Manual Conventions Used in This Manual................................................................................. ixRelated Documentation................................................................................
Page 7 - Glossary
Contents PXI-1006 User Manual viii ni.com Appendix ASpecifications Appendix BPinouts Appendix CTechnical Support Resources Glossary Index Figures Figure 1-1. Installing Controller and PXI Modules ................................................. 1-2 Figure 2-1. Front View of the PXI-1006 Chassis ......
Page 8 - Conventions Used in This Manual; Related Documentation
© National Instruments Corporation ix PXI-1006 User Manual About This Manual The PXI-1006 User Manual describes the features of the PXI-1006 chassis and contains information about configuring the chassis, installing themodules, and operating and using the PXI-1006. Conventions Used in This Manual Th...
Page 10 - For Your Safety; Connecting Safety Ground
© National Instruments Corporation xi PXI-1006 User Manual For Your Safety Caution Before undertaking any troubleshooting, maintenance, or exploratory procedure, carefully read the warning and caution notices. This equipment contains voltage hazardous to human life and safety, andcan inflict persona...
Page 11 - Installing and Verifying Operation; Unpacking the PXI-1006 and Installing a Controller
© National Instruments Corporation 1-1 PXI-1006 User Manual 1 Installing and Verifying Operation This chapter describes how to unpack the PXI-1006, install a controller,and verify that the chassis is operating correctly. Unpacking the PXI-1006 and Installing a Controller This installation example as...
Page 13 - Key Features
© National Instruments Corporation 2-1 PXI-1006 User Manual 2 PXI-1006 Features This chapter describes the key features of the PXI-1006 chassis and listsoptional equipment you can order from National Instruments. Key Features The PXI-1006 combines a high-performance 18-slot PXI backplane with ahigh-...
Page 14 - PXI-1006 Backplane Overview; Interoperability with CompactPCI
Chapter 2 PXI-1006 Features PXI-1006 User Manual 2-2 ni.com PXI-1006 Backplane Overview Interoperability with CompactPCI The PXI-1006 backplane is interoperable with PXI-compatible productsand standard CompactPCI products. This is an important feature, as manyPXI-compatible systems may require compo...
Page 16 - System Controller Slot
Chapter 2 PXI-1006 Features PXI-1006 User Manual 2-4 ni.com System Controller Slot The System Controller slot is Slot 1 of the chassis as defined by the PXIspecification. It has three controller expansion slots, which are used forsystem controller modules that are wider than one slot. As defined in ...
Page 17 - Bac
Chapter 2 PXI-1006 Features © National Instruments Corporation 2-5 PXI-1006 User Manual Figure 2-3. PXI Local Bus and Star Trigger Routing 3 4 5 6 7 8 9 10 11 12 14 15 13 17 18 16 Local Bus Local Bus Local Bus Local Bus Local Bus Local Bus Local Bus Local Bus Local Bus Local Bus Local Bus Local Bus ...
Page 18 - Trigger Bus; Rack Mounting
Chapter 2 PXI-1006 Features PXI-1006 User Manual 2-6 ni.com Trigger Bus The PXI-1006 has three PXI segments. Vertical bars represent the segmentdivisions on the front of the chassis. (See Figure 2-1 for the segment dividerlocations.) The PXI trigger bus is divided into three separate trigger busesat...
Page 19 - Remote Power Monitoring and Inhibiting Interface; Using the Inhibiting Feature
Chapter 2 PXI-1006 Features © National Instruments Corporation 2-7 PXI-1006 User Manual Remote Power Monitoring and Inhibiting Interface The PXI-1006 chassis supports remote power monitoring and inhibiting viaa 9-pin D-sub connector located on the rear panel. Table 2-1 shows thepinout of the DB-9 co...
Page 20 - Using the Power Monitoring Feature
Chapter 2 PXI-1006 Features PXI-1006 User Manual 2-8 ni.com Using the Power Monitoring Feature You can use a digital voltmeter to ensure all voltage levels in yourPXI-1006 are within the allowable limits. Caution When connecting digital voltmeter probes to the rear D-sub connector, be careful not to...
Page 21 - Installing Filler Panels; Interior Cleaning
Chapter 2 PXI-1006 Features © National Instruments Corporation 2-9 PXI-1006 User Manual Installing Filler Panels To optimize module cooling performance, install filler panels into unusedor empty slots. Secure with the captive mounting screws. Using the Chassis Initialization File To assist system in...
Page 22 - Cleaning the Fan Filters
Chapter 2 PXI-1006 Features PXI-1006 User Manual 2-10 ni.com Caution Avoid getting moisture inside the chassis during exterior cleaning. Use just enough moisture to dampen the cloth. Do not wash the front- or rear-panel connectors or switches. Cover these components while cleaning the chassis. Do no...
Page 23 - Troubleshooting the PXI-1006
© National Instruments Corporation 3-1 PXI-1006 User Manual 3 Troubleshooting This chapter describes basic troubleshooting procedures you can performon the PXI-1006 chassis. Troubleshooting the PXI-1006 Refer to Table 3-1 to troubleshoot the PXI-1006 chassis. The table listspossible causes for power...
Page 25 - Specifications; Electrical
© National Instruments Corporation A-1 PXI-1006 User Manual A Specifications This appendix contains specifications for the PXI-1006 chassis. Electrical AC Input Input voltage range................................. 90–264 VAC Input frequency range ............................ 47 to 63 Hz Over-current...
Page 26 - DC Output; Cooling
Appendix A Specifications PXI-1006 User Manual A-2 ni.com DC Output Maximum usable power .........................600 W DC current capacity (I MP ) Load regulation Maximum ripple and noise .....................1% ripple, 1% noise 20 MHz bandwidth Over-current protection...........................105...
Page 27 - Electromagnetic Compatibility; Safety
Appendix A Specifications © National Instruments Corporation A-3 PXI-1006 User Manual Slot airflow direction.............................. P1 to P2, bottom of module to top of module Module/power supply cooling intake ..... Three rear fans Module cooling exhaust ......................... Along both ...
Page 28 - Backplane
Appendix A Specifications PXI-1006 User Manual A-4 ni.com Functional shock (operating) ..................MIL-T-28800E CLASS 3, Half-Sine Shock Pulse, 11 msduration, 30 g peak Operating location ..................................Indoor use only Random vibration Operational 1 ............................
Page 29 - Mechanical
Appendix A Specifications © National Instruments Corporation A-5 PXI-1006 User Manual Mechanical Weight .................................................... 13.2 kg (29.2 lb.) Maximum module weight ...................... 1.8 kg (4 lb.) Materials................................................. Sheet...
Page 31 - Pinouts
© National Instruments Corporation B-1 PXI-1006 User Manual B Pinouts This appendix describes the P1 and P2 connector pinouts for the PXI-1006backplane. Table B-1 shows the P1 (J1) connector pinout for the SystemController slot. Table B-2 shows the P2 (J2) connector pinout for the SystemController s...
Page 38 - Technical Support Resources; Web Support; Customer Education; System Integration
© National Instruments Corporation C-1 PXI-1006 User Manual C Technical Support Resources Web Support National Instruments Web support is your first stop for help in solvinginstallation, configuration, and application problems and questions. Onlineproblem-solving and diagnostic resources include fre...
Page 39 - Worldwide Support
Appendix C Technical Support Resources PXI-1006 User Manual C-2 ni.com Worldwide Support National Instruments has offices located around the world to help addressyour support needs. You can access our branch office Web sites from theWorldwide Offices section of ni.com . Branch office Web sites provi...
Page 40 - Symbols
© National Instruments Corporation G-1 PXI-1006 User Manual Glossary Prefix Meanings Value n- nano- 10 – 9 µ- micro- 10 – 6 m- milli- 10 – 3 c- centi- 10 – 2 k- kilo- 10 3 M- mega- 10 6 Symbols ° Degrees ≥ Equal or greater than ≤ Equal or less than % Percent A A Amperes AC Alternating current Ah Amp...
Page 44 - Index
© National Instruments Corporation I-1 PXI-1006 User Manual Index B backplane, 2-2 interoperability with CompactPCI, 2-2local bus, 2-4overview, 2-2peripheral slots, 2-4specifications, A-4Star Trigger (ST) slot, 2-4system reference clock, 2-6trigger bus, 2-6 C chassis initialization file, 2-9chassis ...