Page 2 - What You Need to Get Started; SSR Series module backplane kit and documentation; Module Operation; Note; Input Modules
SSR Series Modules and Backplanes 2 © National Instruments Corporation What You Need to Get Started To set up and use the SSR Series modules and backplanes you need the following: ❑ SSR Series module backplane kit and documentation ❑ SSR Series module ❑ National Instruments DAQ device ❑ Cable and/or...
Page 3 - Manufacturer Data Sheets; to the -DC control. This current must be large; SSR Backplanes; Connection; Minimum Control Logic Current Required; Output Module
© National Instruments Corporation 3 SSR Series Modules and Backplanes The dropout voltage and current specifications for the output modules are given in the Manufacturer Data Sheets section. For most control applications, such as controlling motors or lamps, these requirements are not difficult to ...
Page 4 - SSR Backplane Cabling Guide; DAQ Device
SSR Series Modules and Backplanes 4 © National Instruments Corporation The SSR backplanes are divided into ports of eight modules each. The 8-, 16-, 24-, and 32-module backplanes have one, two, three, and four ports respectively. Table 2 shows backplanes that need an interface to convert the digital...
Page 5 - Caution; Configuring the Power Supply
© National Instruments Corporation 5 SSR Series Modules and Backplanes Caution Do not attempt to connect the SSR backplane to a host computer DAQ device for which it was not designed. Such connections can damage any or all SSR modules, the host computer, and the DAQ device. National Instruments is n...
Page 6 - Grayhill 8 Module Backplane Jumper Locations
SSR Series Modules and Backplanes 6 © National Instruments Corporation Figure 1. Grayhill 8 Module Backplane Jumper Locations Figure 2. Grayhill 16 Module Backplane Jumper Locations Figure 3. Grayhill 24 Module Backplane Jumper Locations 1 DAQ Device Power Jumper Location (use only one) 2 Not Used 1...
Page 7 - Grayhill 32 Module Backplane Jumper Locations; Crouzet 8 Module Backplane Jumper Locations; External Power Fuse; Note: No DAQ Device Power Jumper Location
© National Instruments Corporation 7 SSR Series Modules and Backplanes Figure 4. Grayhill 32 Module Backplane Jumper Locations Note The Grayhill 32-module backplane can be powered only by an external power supply. There are no jumper settings. There is a fuse on the external power supply. Figure 5. ...
Page 8 - Crouzet 16 Module Backplane Jumper Locations; SSR Module Installation; External Power Jumper
SSR Series Modules and Backplanes 8 © National Instruments Corporation Figure 6. Crouzet 16 Module Backplane Jumper Locations Figure 7. Crouzet 24 Module Backplane Jumper Locations Note The Crouzet 32 module backplane has no position on the backplane for either a fuse or jumper. You must add a power...
Page 9 - output modules the LED is on when the module is turned on. See the; Signal Connections; IAC5 and IAC5A Signal Connections; Digital Signal Conversion
© National Instruments Corporation 9 SSR Series Modules and Backplanes output modules the LED is on when the module is turned on. See the Manufacturer Data Sheets section for further information. Signal Connections Connect external devices to the SSR modules using the screw terminals. Two screw term...
Page 10 - IDC5 Signal Connections; and Crouzet Corporation; Copyright; Digital Conversion
SSR Series Modules and Backplanes 10 © National Instruments Corporation Figure 10. IDC5 Signal Connections Figure 11. ODC5 Signal Connections Manufacturer Data Sheets This section contains the manufacturing data sheets of Grayhill Corporation 1 and Crouzet Corporation 2 . The Grayhill data sheets in...
Page 11 - AC OUTPUT MODULES; G5 FUSES; DIMENSIONS; CIRCUITRY
© National Instruments Corporation 11 SSR Series Modules and Backplanes 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com A n I S O - 9 0 0 1 C o m p a n y AC OUTPUT MODULES FEATURES• Transient Protection: Meets the requirem...
Page 12 - SPECIFICATIONS–All Modules; SPECIFICATIONS BY PART NUMBER
SSR Series Modules and Backplanes 12 © National Instruments Corporation 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com A n I S O - 9 0 0 1 C o m p a n y AC OUTPUT MODULES SPECIFICATIONS–All Modules Specifications apply ov...
Page 13 - DC OUTPUT MODULE
© National Instruments Corporation 13 SSR Series Modules and Backplanes 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com A n I S O - 9 0 0 1 C o m p a n y 70G-ODC 70-ODC 70M-ODC CIRCUITRY Two choices of switching speed vs. ...
Page 14 - SPECIFICATIONS; DC OUTPUT MODULES
SSR Series Modules and Backplanes 14 © National Instruments Corporation 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com A n I S O - 9 0 0 1 C o m p a n y SPECIFICATIONS Specifications apply over operating temperature range...
Page 15 - AC INPUT MODULE
© National Instruments Corporation 15 SSR Series Modules and Backplanes 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com A n I S O - 9 0 0 1 C o m p a n y CIRCUITRY Typical Logic Supply Current Versus LogicSupply VoltageFor...
Page 17 - DC INPUT MODULE
© National Instruments Corporation 17 SSR Series Modules and Backplanes 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com A n I S O - 9 0 0 1 C o m p a n y CIRCUITRY Negative True Logic Modules have either a polarized (Figur...
Page 18 - SPECIFICATIONS–By Part Number (DC Input Only)
SSR Series Modules and Backplanes 18 © National Instruments Corporation 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com A n I S O - 9 0 0 1 C o m p a n y SPECIFICATIONS–All Modules Output Specifications Output Current Rang...
Page 23 - MODULE RACK–Standard; MOUNTING RACKS
© National Instruments Corporation 23 SSR Series Modules and Backplanes 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com A n I S O - 9 0 0 1 C o m p a n y 8 MODULE RACK–Standard Part No. 70RCK8Schematic and Ordering Informa...
Page 24 - ORDERING INFORMATION
SSR Series Modules and Backplanes 24 © National Instruments Corporation 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com A n I S O - 9 0 0 1 C o m p a n y MOUNTING RACKS SCHEMATIC–Part Nos. 70RCK8, 70MRCK8 Part Number I/O D...
Page 25 - 6 MODULE RACK–Standard
© National Instruments Corporation 25 SSR Series Modules and Backplanes 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com A n I S O - 9 0 0 1 C o m p a n y MOUNTING RACKS 55 16 MODULE RACK–Standard Part No. 70RCK16Schematic ...
Page 26 - SCHEMATIC–Part No. 70GRCK16
SSR Series Modules and Backplanes 26 © National Instruments Corporation 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com A n I S O - 9 0 0 1 C o m p a n y SCHEMATIC–Part Nos. 70RCK16 and 70MRCK16 SCHEMATIC–Part No. 70GRCK16...
Page 27 - 4 MODULE RACK–Standard
© National Instruments Corporation 27 SSR Series Modules and Backplanes 561 Hillgrove Avenue • LaGrange, Illinois 60525 • USA • Phone: (708) 354-1040 • Fax: (708) 354-2820 • http://www.grayhill.com A n I S O - 9 0 0 1 C o m p a n y 24 MODULE RACK–Standard Part No. 70RCK24Dimensions are shown in inch...